Diode Symmetrical rail diode module 12-24 V DC/2x20 A or 1x40 A. Continuous redundancy to the consumer.

Automation > Surge protection module
Power Supplies (PS)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2907719
Packing unit1 pc
Catalog pagePage 264 (C-4-2017)
GTIN4055626231211
Weight per Piece (excluding packing)953.000 g
Custom tariff number85049091
Country of originCN (China)

Dimensions

Width50 mm
Height130 mm
Depth125 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2
Installation height≤ 2000 m

Input data

Nominal input voltage range12 V DC ... 24 V DC
12 V DC ... 24 V DC
Input voltage range10 V DC ... 30 V DC
10 V DC ... 30 V DC
Nominal input current2x 20 A (-40 °C ... 60 °C)
1x 40 A (-40 °C ... 60 °C)
Maximum input current2x 30 A (-40 °C ... 40 °C)
1x 60 A (-40 °C ... 40 °C)
Nominal input current2x 20 A (-25 °C ... 60 °C)
1x 40 A (-25 °C ... 60 °C)
Maximum input current2x 30 A (-25°C ... 40°C)
1x 60 A (-25°C ... 40°C)

Output data

Output voltage range12 V DC ... 24 V DC
Nominal output current (IN)40 A (Increasing power)
20 A (Redundancy)
Derating60 °C ... 70 °C (2.5%/K)
Connection in seriesNo
Power loss nominal load max.10 W (IOUT= 20 A)

General

Net weight0.75 kg
Efficiency> 97 %
Insulation voltage input/outputtype test
routine test
Insulation voltage input / PEtype test
routine test
Protection classIII
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)
40000000 h (40 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.16 mm²
Conductor cross section AWG min.10
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.16 mm²
Conductor cross section AWG min.10
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with LV directive 2006/95/EC
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
ATEX II 3G Ex nA IIC T4 Gc
KEMA 10 ATEX 0165X
IECExEx nA IIC T4 Gc
IECEx KEM 10.0091

Environmental Product Compliance

REACh SVHCLead 7439-92-1

Classifications


ETIM for 2907719 Low-voltage industrial controls and switchgear (EC000683)
Feature Name Feature Value
Function (EF000030) Other
Voltage type (operating voltage) (EF005294) DC
Operating voltage DC (EF008208) 10 V
With LED indication (EF005950) No

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.