PHOENIX CONTACT SAC-4PM12MSD/10-936/BP-M12FSD SAC-4PM12MSD/10-936/BP-M12FSD 1401035 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4PM12MSD/10-936/BP-M12FSD 1401035 PHOENIX CONTACT Bus system cable

SAC-4PM12MSD/10-936/BP-M12FSD

1401035

PHOENIX CONTACT

25 Pcs.

Bus system cable Bus system cable, PROFINET, 4-pole, PE-X, black RAL 9005, shielded, Straight connector M12, coding: D, a Female of built-in mounting M12, coding: D, cable length: 10 m Device connector rear mounting, degree of protection: IP65/IP67/IP69K, cable length: 10 m, number of positions: 4, PROFINET

Automation > Sensor-actuator patch cord
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeCircular connectors (device side)
Sensor typePROFINET
Number of positions4
Shieldedyes
CodingD
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Material specifications
Flammability rating according to UL 94V0
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material for screw connectionZinc die-cast, nickel-plated
Outer sheath, materialPE-X

Electrical properties
Nominal voltage UN48 V AC
Nominal current IN4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Connector
Connection 1
TypePlug straight M12
Coding typeD (Data)
Connection 2
TypeFlush-type female connector M12
Coding typeD (Data)

Cable/line
Cable length10.00 m
PROFINET RADOX® railway application CAT5 reinforced [936]
Dimensional drawingjtvtrckflp.jpg
Cable weight81 g/m
Number of positions4
Shieldedyes
Cable typePROFINET RADOX® railway application CAT5 reinforced [936]
Conductor structure1x4xAWG22/7, SF/TQ
Signal speed66 c
Conductor structure signal line7x 0.25 mm
AWG signal line22
Conductor cross section4x 0.34 mm²
Wire diameter incl. insulation1.95 mm
External cable diameter7.25 mm ±0.3 mm
Outer sheath, materialPE-X
External sheath, colorblack RAL 9005
Conductor materialsilver-plated Cu litz wires
Material wire insulationPE-X
Single wire, colorwhite-blue, orange-yellow
Thickness, outer sheath≥ 0.80 mm
Overall twistStar quad
Optical shield covering100 %
Max. conductor resistance≤ 54.4 Ω/km
Coupling resistance200.00 mΩ/m (f ≤ 30 MHz)
Wave impedance100 Ω ±5 Ω (f = 100 MHz)
Working capacitance≤ 65 pF (Line-line)
≤ 100 pF (Line-shield)
Nominal voltage, cable300 V AC
Test voltage2000 V AC (50 Hz, 5 minutes)
Minimum bending radius, fixed installation6 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation44 mm
Smallest bending radius, movable installation73 mm
Near end crosstalk attenuation (NEXT)80 dB (with 1 MHz)
76 dB (at 4 МHz)
67 dB (at 10 MHz)
60 dB (at 31.5 МHz)
56 dB (at 62.5 МHz)
53 dB (at 100 MHz)
Return attenuation (RL)35 dB (at 4 МHz)
35 dB (at 10 MHz)
35 dB (at 31.5 МHz)
33 dB (at 62.5 МHz)
33 dB (at 100 MHz)
Remote crosstalk attenuation (FEXT)80 dB (with 1 MHz)
70 dB (at 4 МHz)
65 dB (at 10 MHz)
58 dB (at 31.5 МHz)
59 dB (at 62.5 МHz)
67 dB (at 100 MHz)
Shield attenuation2 dB (with 1 MHz)
4 dB (at 4 МHz)
6.5 dB (at 10 MHz)
10.5 dB (at 31.5 МHz)
14 dB (at 62.5 МHz)
18 dB (at 100 MHz)
40.00 dB (30 MHz ≤ f ≤ 100 MHz)
Halogen-freein accordance with EN 50267-2-1
Flame resistanceEN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Other resistanceResistance to fuels (according to IRM 903, 168 h at 70 °C)
Ambient temperature (operation)-50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (Cable, flexible installation)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67
IP65/IP67/IP69K
Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
-40 °C ... 90 °C (cable, fixed installation)
-25 °C ... 90 °C (Cable, flexible installation)

ETIM for 1401035 Sensors (EC001855)
Feature Name Feature Value
Number of poles (EF001391) 4
Type of electrical connection, field-sided (EF005525) M12
Type of plug-in contact, field sided (EF006269) Male (plug)
Positioning cable feed, field-sided (EF005928) Straight
Type of electrical connection, box-sided (EF005524) M12
Type of plug-in contact, box-sided (EF008386) Female (bus)
Cable length (EF000536) 10 m
Material of cable sheath (EF004136) Other
Halogen free (EF000025) Yes
Colour cable sheath (EF008249) Other
With LED indication (EF005950) No
Screened (EF000881) Yes
Cable type (EF000081) Multi-core
Vulcanize (EF004115) No
Material contact body (EF008248) CuSn
Material of contact surface (EF004020) Other
Permitted cable outer temperature after assembling without vibration (EF001686) -50 °C
Permitted cable outer temperature during assembling/handling (EF001685) -40 °C
Rated current In (EF008250) 4 A
Rated voltage (EF000228) 48 V
Degree of protection (IP) (EF005474) IP65

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.