PHOENIX CONTACT PTVFIX 6/18X2,5 BK PTVFIX 6/18X2,5 BK 1019651 PHOENIX CONTACT Distribution block, nominal voltage: 450 V, nominal current: 24 A.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PTVFIX 6/18X2,5 BK 1019651 PHOENIX CONTACT Distribution block, nominal voltage: 450 V, nominal current: 24 A..

PTVFIX 6/18X2,5 BK

1019651

PHOENIX CONTACT

20 Pcs.

Distribution block, nominal voltage: 450 V, nominal current: 24 A, number of connections: 19, number of poles: 1, connection type: Push-in connection, Bypass, Dimensioning section: 2.5 mm², cross-section: 0.14 mm² - 4 mm², Collective connection, Dimensioning section: 6 mm², cross-section: 0.5 mm² - 10 mm², installation type: interlocking on rail adapter, Direct mounting with a flange, Aerial, Color: Black Distribution block, nom. voltage: 450 V, nominal current: 24 A, number of connections: 19, number of positions: 1, connection method: Push-in connection, Load contact, Rated cross section: 2.5 mm2, cross section: 0.14 mm2 - 4 mm2, Line contact, Rated cross section: 6 mm2, cross section: 0.5 mm2 - 10 mm2, mounting type: for snapping onto a DIN rail adapter, Direct mounting with flange, Free-hanging, color: black

Automation > Feed-through terminal block
FIX block System

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeDistributor terminal block
Number of positions1
Number of connections19
Number of rows1
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Rated surge voltage8 kV
Maximum power dissipation for nominal condition0.77 W

Connection data
Service Entranceyes
Number of connections per level19
Nominal cross section2.5 mm²
Cross section AWG(converted acc. to IEC)
Load contact
Stripping length8 mm ... 10 mm
Internal cylindrical gageA3
B3
Connection in acc. with standardIEC 60998-2-2
Conductor cross section rigid0.14 mm² ... 4 mm²
Cross section AWG26 ... 12 (converted acc. to IEC)
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]26 ... 14 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve)0.5 mm²
Nominal current24 A
Maximum load current32 A (with 4 mm² conductor cross section)
Maximum total current57 A (with 10 mm² conductor cross section)
Nominal voltage450 V
Nominal cross section2.5 mm²
Line contact
Stripping length10 mm ... 12 mm
Internal cylindrical gageA5
B4
Conductor cross section rigid0.5 mm² ... 10 mm²
Cross section AWG20 ... 8 (converted acc. to IEC)
Conductor cross section flexible0.5 mm² ... 6 mm²
Conductor cross section, flexible [AWG]20 ... 10 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.5 mm² ... 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.5 mm² ... 6 mm²
Conductor cross-section flexible (2 conductors with the same cross-section, with TWIN ferrule and plastic sleeve)0.5 mm² ... 1.5 mm²
Nominal current41 A (with 6 mm² conductor cross section)
Maximum load current57 A (with 10 mm² conductor cross section)
Nominal cross section6 mm²
Load contact Connection cross sections directly pluggable
Conductor cross section rigid0.34 mm² ... 4 mm²
Conductor cross section, rigid [AWG]22 ... 18 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.5 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.34 mm² ... 2.5 mm²
Line contact Connection cross sections directly pluggable
Conductor cross section rigid1 mm² ... 10 mm²
Conductor cross section, rigid [AWG]18 ... 8 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)1 mm² ... 6 mm²
Flexible conductor cross section (ferrule with plastic sleeve)1 mm² ... 6 mm²

Dimensions
Width56.9 mm
Height28.6 mm
Depth21.7 mm

Material specifications
Colorblack
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C

Mechanical properties
Mechanical data
Open side panelNo

Environmental and real-life conditions
Ambient conditions
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC 60998-2-2

Mounting
Mounting typefor snapping onto a DIN rail adapter
Direct mounting with flange
Free-hanging

ETIM for 1019651 Terminal blocks (EC000897)
Feature Name Feature Value
Rated current In (EF008250) 24 A
Rated voltage (EF000228) 450 V
Type of electrical connection 1 (EF002526) Other
Type of electrical connection 2 (EF002527) Other
Number of clamp positions per level (EF002660) 19
Material insulation body (EF007543) Other
Inflammability class of insulation material according to UL94 (EF002521) V0
Width (EF000008) 56.9 mm
Height (EF000040) 28.6 mm
Depth (EF000049) 21.7 mm
Closing plate required (EF002525) No
Colour (EF000007) Black
Internally connected stages (EF002661) Yes

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.