Key Commercial Data

Orderkey1627060
Packing unit1 pc
NoteMade to Order (non-returnable)
GTIN4055626298795
Weight per Piece (excluding packing)772.000 g
Custom tariff number90230080
Country of originDE (Germany)

General

Type of lockingSPEEDCON locking
Direction of rotation of contact chamber numberingStandard
CodingCAT5, coding 1
Contact connection methodCrimp connection
Number of positions13
Contact diameter of power contacts3.6 mm
Litz wire cross section of power contacts min.1 mm²
Litz wire cross section of power contacts max.16 mm²
Nominal current per power contact at 25°C70 A
Contact diameter of signal contacts1 mm
Litz wire cross section of signal contacts min.0.06 mm²
Litz wire cross section of signal contacts max.1.5 mm²
Nominal current per signal contact at 25°C8 A
Contact diameter, data contacts0.8 mm
Litz wire cross section, data contacts, min.0.08 mm²
Litz wire cross section, data contacts, max.0.5 mm²
Nominal current per data contact at 25°C3.6 A
Pg housing screw connectionnone

Ambient conditions

Degree of protectionIP67

Specifications according to DIN EN 61984:2001

Nominal / operating voltage of power contacts630 V AC
Rated surge voltage of power contacts6 kV
Overvoltage category of power contactsIII
Degree of pollution of power contacts3
Nominal / operating voltage of signal contacts500 V
Rated surge voltage of signal contacts1.5 kV
Overvoltage category of signal contactsIII
Degree of pollution of signal contacts3

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”