PHOENIX CONTACT AXL F DI8/2 48/60DC 1F AXL F DI8/2 48/60DC 1F 2702654 PHOENIX CONTACT I/O module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

AXL F DI8/2 48/60DC 1F 2702654 PHOENIX CONTACT I/O module

AXL F DI8/2 48/60DC 1F

2702654

PHOENIX CONTACT

1 Pcs.

I/O module AxiolineF, Digital input module, Digital inputs: 8, 48 VDC / 60 VDC, connection technology: 2 conductors, corresponds to IEC 61850-3 standard, transmission speed on the local bus:100 MBit/s, protection index: IP20, including bus socket module and AxiolineF connectors Axioline F, Digital input module, Digital inputs: 8, 48 V DC / 60 V DC, connection technology: 2-conductor, corresponds to standard IEC 61850-3, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors

Automation > Fieldbus, decentr. periphery - digital I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Dimensions
Dimensional drawingrdmkzsqava.jpg
Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Notes
Note on application
Note on applicationOnly for industrial use

Interfaces
Axioline F local bus
Number of interfaces2
Connection methodBus base module
Transmission speed100 Mbps

System properties
Module
Input address area1 Byte
Output address area0 Byte
Required parameter data3 Byte
Required configuration data6 Byte

Input data
Digital:
Input nameDigital inputs
Description of the inputEN 61131-2 type 1
Number of inputs8
Connection methodPush-in connection
Connection technology2-conductor
Input voltage48 V (Nominal voltage)
60 V (Nominal voltage)
max. 100 V DC
Input voltage range-100 V DC ... 100 V DC
Input voltage range "0" signal-12 V DC ... 12 V DC
Input voltage range "1" signal32 V DC ... 100 V DC
Nominal input voltage UIN48 V DC
60 V DC
Nominal input current at UIN2.5 mA
Input filter time< 1 ms
Protective circuitPolarity reversal protection of the inputs

Product properties
Product typeI/O component
Product familyAxioline F
Typeblock modular
Mounting positionany (no temperature derating)
Nominal mounting position: wall mounting on horizontal DIN rail
Scope of deliveryincluding bus base module and Axioline F connectors
Special propertiescorresponds to standard IEC 61850-3
Data management status
Article revision01
Insulation characteristics
Overvoltage categoryIII (EN 61010-2-201/IEC 61010-2-201)
Pollution degree2

Electrical properties
Maximum power dissipation for nominal condition1.8 W
Potentials: Axioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current drawmax. 120 mA
Electrical isolation/isolation of the voltage ranges
Test voltage: I/Os / logic4 kV
5 kV
Test voltage: I/O/functional ground4 kV
5 kV
Test voltage: I/O / I/O (adjacent connectors)2.5 kV
Test voltage: Logic/functional ground1 kV

Connection data
Connection technology
Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor connection
Connection methodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm
Axioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-25 °C ... 60 °C
Degree of protectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and regulations
Standard designationAmbient conditions
Standards/specificationsIEC 61850-3

Mounting
Mounting typeDIN rail mounting
Mounting positionany (no temperature derating)
Nominal mounting position: wall mounting on horizontal DIN rail

ETIM for 2702654 PLC's (EC001599)
Feature Name Feature Value
Voltage type (supply voltage) (EF002991) DC
Number of digital inputs (EF001992) 8
Number of digital outputs (EF001993) 0
Digital inputs configurable (EF008516) No
Digital outputs configurable (EF008520) No
Input current at signal 1 (EF001428) 0.0025 mA
Permitted voltage at input (EF007554) -12 V
Type of voltage (input voltage) (EF003033) DC
Type of digital output (EF003601) None
Short-circuit protection, outputs available (EF003203) No
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 0
With optical interface (EF003028) No
Supporting protocol for EtherCAT (EF017564) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for other bus systems (EF003062) Yes
Radio standard Bluetooth (EF007178) No
Radio standard WLAN 802.11 (EF007179) No
Radio standard GPRS (EF008523) No
Radio standard GSM (EF008524) No
Radio standard UMTS (EF008525) No
IO link master (EF007298) No
System accessory (EF004118) Yes
Degree of protection (IP) (EF005474) IP20
Type of electric connection (EF003961) Other
Time delay at signal change (EF002382) 0 ms
Fieldbus connection over separate bus coupler possible (EF004002) Yes
Suitable for rail mounting (EF003972) Yes
Wall mounting/direct mounting (EF007020) No
Front built-in possible (EF007016) No
Rack-assembly possible (EF007018) No
Suitable for safety functions (EF001597) No
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Width (EF000008) 53.6 mm
Height (EF000040) 125.893725 mm
Depth (EF000049) 52.589698 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.