PHOENIX CONTACT PTIO 1,5/S/3-L-R100K/O-M 120V PTIO 1,5/S/3-L-R100K/O-M 120V 3209034 PHOENIX CONTACT Sensor/actuator terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PTIO 1,5/S/3-L-R100K/O-M 120V 3209034 PHOENIX CONTACT Sensor/actuator terminal block

PTIO 1,5/S/3-L-R100K/O-M 120V

3209034

PHOENIX CONTACT

50 Pcs.

Sensor/actuator terminal block Terminal block for detectors/actuators, with 100 kOhm resistance, nominal voltage: 250 V, nominal current: 13.5 A, number of connections: 4, connection type: Push-in connection, Dimensioning cross-section: 1.5 mm², cross-section: 0.14 mm² - 1.5 mm², mounting class: NS 35/7.5, NS 35/15, color: gray Initiator/actuator terminal block, with 100 kOhm resistor, nom. voltage: 250 V, nominal current: 13.5 A, number of connections: 4, connection method: Push-in connection, Rated cross section: 1.5 mm2, cross section: 0.14 mm2 - 1.5 mm2, mounting type: NS 35/7,5, NS 35/15, color: gray

Automation > Sensor/actuator terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Product properties
Product typeSensor/actuator terminal block
Number of connections4
Number of rows2
Potentials3
Data management status
Article revision03
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Electrical properties
Rated surge voltage4 kV
Maximum power dissipation for nominal condition0.4 W

Connection data
Number of connections per level2
Nominal cross section1.5 mm²
Stripping length8 mm ... 10 mm
Internal cylindrical gageA1 / B1
Connection in acc. with standardIEC 60947-7-1
Conductor cross section rigid0.14 mm² ... 1.5 mm²
Cross section AWG26 ... 16 (converted acc. to IEC)
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section, flexible [AWG]26 ... 16 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve)0.14 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.14 mm² ... 2.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve0.5 mm²
Nominal current13.5 A
Maximum load current13.5 A (with 1.5 mm² conductor cross section)
Nominal voltage250 V
Nominal cross section1.5 mm²
Connection cross sections directly pluggable
Conductor cross section rigid0.25 mm² ... 1.5 mm²
Conductor cross-section flexible (ferrule without plastic sleeve)0.34 mm² ... 1.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve)0.34 mm² ... 1 mm²

Dimensions
Width3.5 mm
End cover width2.2 mm
Height74.4 mm
Depth on NS 35/7,541.5 mm
Depth on NS 35/1549 mm

Material specifications
Colorgray (RAL 7042)
Flammability rating according to UL 94V0
Insulating material groupI
Insulating materialPA
Static insulating material application in cold-60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed

Mechanical properties
Mechanical data
Open side panelYes

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport)-25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C)
Ambient temperature (assembly)-5 °C ... 70 °C
Ambient temperature (actuation)-5 °C ... 70 °C
Permissible humidity (operation)20 % ... 90 %
Permissible humidity (storage/transport)30 % ... 70 %

Standards and regulations
Connection in acc. with standardIEC 60947-7-1

Mounting
Mounting typeNS 35/7,5
NS 35/15

ETIM for 3209034 Terminal blocks (EC000900)
Feature Name Feature Value
Connectable conductor cross section fine-strand without cable end sleeve (EF007341) 0.14 mm²
Connectable conductor cross section fine-strand with cable end sleeve (EF007339) 0.14 mm²
Connectable conductor cross section solid-core (EF007337) 0.14 mm²
Rated current In (EF008250) 13.5 A
Rated voltage (EF000228) 250 V
Number of levels (EF002659) 2
Number of clamp positions per level (EF002660) 2
Internally connected stages (EF002661) No
Type of electrical connection 1 (EF002526) Other
Type of electrical connection 2 (EF002527) Other
Mounting method (EF000003) Other
Cross connectable (EF005717) Yes
Material insulation body (EF007543) Other
Inflammability class of insulation material according to UL94 (EF002521) V0
Width (EF000008) 3.5 mm
Height (EF000040) 74.4 mm
Depth (EF000049) 41.5 mm
Colour (EF000007) Grey
With PE connection (EF002534) No
With shield connection (EF002535) No
Disconnect function (EF006183) No

Product Datasheet