View larger
SAC-4P-10,0-CEI/M12FR-2L DS
1575521
PHOENIX CONTACT
50 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 1575521 |
|---|---|
| Packing unit | 10 pc |
| Minimum order quantity | 50 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4046356434911 |
| Weight per Piece (excluding packing) | 403.040 g |
| Custom tariff number | 85444290 |
| Country of origin | PL (Poland) |
| Ambient temperature (operation) | -25 °C ... 90 °C (Plug / socket) |
|---|---|
| Degree of protection | IP67 |
| Rated current at 40°C | 4 A |
|---|---|
| Rated voltage | 24 V |
| 24 V DC | |
| Number of positions | 4 |
| Coding | A - standard |
| Status display | 2 LEDs |
| Overvoltage category | II |
| Degree of pollution | 3 |
| Insertion/withdrawal cycles | ≥ 100 |
| Flammability rating according to UL 94 | HB |
|---|---|
| Contact material | CuSn |
| Contact surface material | Ni/Au |
| Contact carrier material | TPU GF |
| Material of grip body | TPU, hardly inflammable, self-extinguishing |
| Material, knurls | Zinc die-cast, nickel-plated |
| Sealing material | NBR |
| Cable type | PVC gray |
|---|---|
| Cable type (abbreviation) | CEI |
| Cable abbreviation | LiYY |
| Conductor cross section | 4x 0.25 mm² |
| AWG signal line | 24 |
| Conductor structure signal line | 32x 0.10 mm (VDE 0295 Class 6) |
| Core diameter including insulation | 1.4 mm ±0.05 mm |
| Wire colors | brown, white, blue, black |
| External sheath, color | gray RAL 7035 |
| External cable diameter D | 5 mm +0.1 mm (CEI 20/11 RZ) |
| Minimum bending radius, fixed installation | 10 x D |
| Outer sheath, material | PVC |
| Material conductor insulation | PVC (CEI 20/11 R2) |
| Conductor material | Bare Cu litz wires |
| Conductor resistance | < 74 Ω/km (at 20 °C) |
| Nominal voltage, cable | 300 V |
| Test voltage Core/Core | 3000 V (rms) |
| Flame resistance | in accordance with CEI 20-22II |
| according to IEC 332-3 | |
| Resistance to oil | in accordance with ISO 6722 |
| Other resistance | Resistance to low temperatures acc. to EN 60811-1-4 |
| Resistance to high temperatures in accordance with ISO 6722 (3000 h) | |
| Ambient temperature (operation) | -25 °C ... 80 °C (cable, fixed installation) |
| -20 °C ... 80 °C (cable, flexible installation) |