PHOENIX CONTACT PTCB E1 24DC/1-8A NO2 PTCB E1 24DC/1-8A NO2 1388391 PHOENIX CONTACT 1-channel electronic switch for equipment protection to protec.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PTCB E1 24DC/1-8A NO2 1388391 PHOENIX CONTACT 1-channel electronic switch for equipment protection to protec..

PTCB E1 24DC/1-8A NO2

1388391

PHOENIX CONTACT

1 Pcs.

1-channel electronic switch for equipment protection to protect consumers in 24 V DC in case of overload and short circuit. Easy potential distribution with the components of the CLIPLINE complete terminal block system. With electronic locking of the set rated currents. The warning contact opens when the channel is disconnected due to a fault or manually. For installation on DIN rails. 1-channel, electronic circuit breaker for protecting loads at 24 V DC against overload and short circuit. Easy potential distribution with components from the CLIPLINE complete terminal block system. With electronic interlock of the set nominal currents. The signal contact opens if the channel has been switched off manually or due to a fault. For installation on DIN rails.

Automation > Device circuit breaker
Over Current Protection

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
General
NoteEN 50121-3-2: Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock – Apparatus
Connection for signal line tested in accordance with EN 61000-4-4 with 1 kV; if necessary, customer must provide appropriate protective measures
Repeated hard short circuits can reduce the melting integral of the integrated backup fuse.

Product properties
TypeDIN rail module, one-piece
Product typeDevice circuit breakers
Product familyPTCB
Number of positions1
Insulation characteristics
Protection classIII
Pollution degree2

Electrical properties
General
Operating voltage18 V DC ... 30 V DC
Rated voltage24 V DC
Rated current IN24 A DC (Total current input)
8 A DC (Rated current output)
Rated current IN1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 A DC (adjustable)
Rated current (pre-adjusted)4 A
Rated surge voltage0.5 kV
Tripping methodE (electronic)
Feedback resistancemax. 35 V DC
Required backup fuseOnly required if Imaxof the power supply > the short-circuit switching capacity. Integrated failsafe element.
Short-circuit switching capacity300 A
Dielectric strengthmax. 35 V DC (Load circuit)
Fuseelectronic
Efficiency> 99 %
Closed circuit current I0typ. 12 mA
Power dissipationtyp. 0.3 W (No-load operation)
< 1.6 W (Nominal operation)
Module initialization time< 0.55 s
Waiting time after switch off of a channel5 s (at overload / short circuit)
Measuring tolerance I± 15 %
Temperature derating21 A (Total current at 60°C)
24 A (Total current at 50°C)
7 A (Channel current at 60°C)
8 A (Channel current at 50°C)
MTBF (IEC 61709, SN 29500)25641025 h (at 25 °C with 21 % load)
10989010 h (at 40°C with 34.25% load)
1149425 h (at 55°C with 100% load)
Voltage drop0.13 V (at 8 A)
Fail-safe element15 A DC
Load circuit
Shutdown time≤ 10 ms (for short circuit > 2.0 x IN)
1 s (1.2 ... 2.0 x IN)
Undervoltage switch-off≤ 17.8 V DC (active)
≥ 18.8 V DC (inactive)
Overvoltage switch-off≥ 30.5 V DC (active)
≤ 29.5 V DC (inactive)
Max. capacitive load25000 µF (Depending on the current setting and the short-circuit current available)
Indicator/remote signaling
Connection nameRemote indication circuit
Switching functionN/O contact
Operating voltage0 V DC ... 30 V DC
Operating current100 mA DC

Connection data
Cross section AWG(converted acc. to IEC)
Main circuit IN+
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.2 mm² ... 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.2 mm² ... 2.5 mm²
Main circuit IN-
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.2 mm² ... 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.2 mm² ... 2.5 mm²
Main circuit OUT
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 12
Conductor cross section, flexible, with ferrule, with plastic sleeve0.2 mm² ... 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.2 mm² ... 2.5 mm²
Remote indication circuit
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section rigid0.2 mm² ... 4 mm²
Conductor cross section AWG24 ... 14
Conductor cross section, flexible, with ferrule, with plastic sleeve0.2 mm² ... 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve0.2 mm² ... 2.5 mm²

Signaling
Channel LED offoff (Channel switched off)
Channel LED yellowlit (Channel switched on, channel load > 80% )
flashing (Programming mode active)
Channel LED greenlit (Channel switched on)
Channel LED redlit (Channel switched off, over- or undervoltage active)
ON temporarily (Channel switched off, 5 s cool-down phase, overload or short-circuit release)
flashing (Channel switched off, ready to be switched back on, overload or short-circuit release)
flashing quickly (Channel switched off, external voltage at the output, possible installation error)

Dimensions
Dimensional drawingxgcytgjdxy.jpg
Width6.2 mm
Height105.8 mm
Depth55.6 mm (incl. DIN rail 7.5 mm)

Material specifications
MaterialPBT
PBT
Flammability rating according to UL 94V-0

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-30 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Altitude≤ 3000 m up to 52 °C (amsl)
≤ 4000 m up to 46 °C (amsl)
Humidity test96 h, 95 % RH, 40 °C
Shock (operation)30g (IEC 60068-2-27, Test Ea)
Vibration (operation)10 Hz ... 59.6 Hz (Amplitude ±0.35 mm; in accordance with IEC 60068-2-6, Test Fc)
59.6 Hz … 150 Hz (Acceleration 5g; in accordance with IEC 60068-2-6, Test Fc)
5 Hz … 100 Hz (Resonance search 4g; resonance frequency 4g; 90 min in accordance with DNV GL Class B)

Approvals
UL approval
IdentificationUL/C-UL Listed UL 508
UL Recognized UL 2367
UL/C-UL Listed ANSI/UL 121201 Class I, Division 2, Groups A, B, C, D; T4 (Hazardous Location)
DNV GL
IdentificationShipbuilding approval
DNV GL data
TemperatureA
HumidityB
VibrationB
EMCB
EnclosureA

Standards and regulations
Standards/specificationsEN 61000-6-2
NoteEMC – Immunity for industrial areas
Standards/specificationsEN 61000-6-3
NoteEMC – Emission for residential, business and commercial properties and small operations
Standards/specificationsEN 60068-2-78
NoteEnvironmental influences – Moisture and heat, constant
Standards/specificationsEN 50178
NoteEquipping power installations with electronic equipment
Standards/specificationsEN 60068-2-6
NoteEnvironmental influences – Vibrations (sinusoidal)
Standards/specificationsEN 60068-2-27
NoteEnvironmental influences – Shocks
Standards/specificationsEN 60068-2-30
NoteEnvironmental influences – Part 2–30: Tests – Test Db: Damp heat, cyclical
Standards/specificationsEN 61373
NoteRailway applications - Rolling stock equipment - Shock and vibration tests
Standards/specificationsEN 45545-2
NoteRailway applications - Fire protection on railway vehicles - Part 2: Requirements for fire behavior of materials and components

Mounting
Mounting typeDIN rail: 35 mm

ETIM for 1388391 Circuit breakers and fuses (EC003538)
Feature Name Feature Value
Inflammability class of insulation material according to UL94 (EF002521) Other
Number of poles (EF001391) 1
Width (EF000008) 6.2 mm
Height (EF000040) 105.8 mm
Depth (EF000049) 55.6 mm
Mounting method (EF000003) Other
Operating voltage (EF000111) 30 V
Nominal current (EF000001) 24 A
Active current limitation x IN (EF011922) 0
Fuse type (EF011923) Electronic
Fail safe element (EF011924) 15 A
Switch-off time (EF011925) 0.01 ms
Max. capacitive load (EF011926) 0.025 µF
With remote signalling contact (EF000422) Yes
Ambient temperature during operating (EF007515) -30 °C

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.