PHOENIX CONTACT PSR-SPP-42-230UC/URM4/4NO/2NC PSR-SPP-42-230UC/URM4/4NO/2NC 2702925 PHOENIX CONTACT Extension module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSR-SPP-42-230UC/URM4/4NO/2NC 2702925 PHOENIX CONTACT Extension module

PSR-SPP-42-230UC/URM4/4NO/2NC

2702925

PHOENIX CONTACT

1 Pcs.

Extension module Expansion of single or two-channel contacts with wide input range, 4 NO contacts, 1 NC contact, 1 feedback circuit, along with base equipment up to cat. 4, PL e according to EN ISO 13849, plug-in push-in terminal, width 22.5 mm

Automation > Device for monitoring of safety-related circuits
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2702925
Packing unit1 pc
Catalog pagePage 263 (C-6-2017)
GTIN4055626428895
Weight per Piece (excluding packing)195.000 g
Custom tariff number85371098
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width22.5 mm
Height112 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitude≤ 2000 m (Above sea level)

Input data

Rated control circuit supply voltage US42 V AC/DC ... 230 V AC/DC -15 % ... +10 % (Rated control circuit supply voltage US)
Rated control supply current IStyp. 35 mA (42 V DC)
typ. 15 mA (230 V AC)
Power consumption at USmax. 1.5 W (with DC)
max. 1.7 W (with AC)
Inrush current< 38 A (Δt = 50 µs at Us)
Typ. starting time with Us< 100 ms (when controlled via A1)
Typical release time< 20 ms (Control via A1 at 42 V DC)
< 200 ms (Control via A1 at 230 V AC)
Recovery time< 1 s
Operating voltage display1 x green LED
Protective circuitSurge protection Suppressor diode and varistors
Maximum switching frequency0.5 Hz

Output data

Contact type4 enabling current paths
1 confirmation current path
1 signaling current path
Contact materialAgSnO2
Maximum switching voltage250 V AC/DC (Observe the load curve)
Minimum switching voltage5 V AC/DC
Limiting continuous current6 A (N/O contact, pay attention to the derating)
1 A (N/C contact 51/52)
6 A (N/C contact 61/62)
Maximum inrush current8 A
Inrush current, minimum10 mA
Sq. Total current72 A2(observe derating)
Interrupting rating (ohmic load) max.1500 VA (N/O contact, 250 V AC, τ = 0 ms)
For additional values, see load curve
Maximum interrupting rating (inductive load)48 W (N/O contact, 24 V DC, τ = 40 ms)
40 W (N/O contact, 48 V DC, τ = 40 ms)
36 W (N/O contact, 60 V DC, τ = 40 ms)
35 W (N/O contact, 110 V DC, τ = 40 ms)
33 W (N/O contact, 220 V DC, τ = 40 ms)
1500 VA (N/O contact, 250 V AC, τ = 40 ms)
Switching capacitymin. 50 mW
Mechanical service life10x 106cycles
Switching capacity according to IEC 60947-5-15 A (24 V (DC13))
5 A (250 V (AC15))
Output fuse6 A gL/gG (N/O contact and N/C contact 61/62)
4 A gL/gG (N/O contact and N/C contact 61/62 for low-demand applications)
1 A gL/gG (N/C contact 51/52)

General

Relay typeElectromechanical relay with forcibly guided contacts in accordance with EN 50205
Nominal operating mode100% operating factor
Net weight195 g
Mounting positionvertical or horizontal
Mounting typeDIN rail mounting
Assembly instructionsSee derating curve
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Housing materialPBT
Housing coloryellow

Connection data

Connection methodSpring-cage connection
pluggableYes
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Safety-related characteristic data

Stop category0
DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)3 (In conjunction with suitable evaluating device)
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)3 (In conjunction with suitable evaluating device)
DesignationEN ISO 13849
Performance level (PL)e (In conjunction with suitable evaluating device)
Category4 (In conjunction with suitable evaluating device)
DesignationEN 62061
Safety Integrity Level Claim Limit (SIL CL)3 (In conjunction with suitable evaluating device)
DesignationEN 50156
Safety Integrity Level (SIL)3

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178/VDE 0160
Rated insulation voltage250 V AC
Rated surge voltage/insulationSafe isolation, reinforced insulation 6 kV:
between (A1/A2) and the remaining current paths
between (51/52) and the remaining current paths
between (61/62) and the remaining current paths
between (13/14, 23/24, 33/34, 43/44) and the remaining current paths
4 kV basic insulation between enabling current paths
Basic insulation 4 kV between all current paths and housing
Degree of pollution2
Overvoltage categoryIII
Shock15g
Vibration (operation)10 Hz ... 150 Hz, 2g
ConformanceCE-compliant

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 2702925 Relays (EC001449)
Feature Name Feature Value
Model (EF000010) Expansion device
Suitable for rail mounting (EF003972) Yes
With detachable clamps (EF003340) Yes
Type of electric connection (EF003961) Spring clamp connection
Suitable for monitoring of emergency-stop circuits (EF007268) No
Suitable for monitoring of valves (EF007272) No
Suitable for monitoring of optoelectronic protection equipment (EF007269) No
Suitable for monitoring of tactile sensors (EF007271) No
Suitable for monitoring of magnetic switches (EF007266) No
Suitable for monitoring of proximity switches (EF007267) No
Evaluation inputs (EF008245) Other
With muting function (EF004057) No
With feedback circuit (EF003343) No
Release-delay (EF001129) 0.1 s
Number of outputs, safety related, undelayed, with contact (EF003344) 0
Number of outputs, safety related, delayed, with contact (EF003345) 0
Number of outputs, safety related, undelayed, semiconductors (EF003346) 0
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, with contact (EF003348) 0
Number of outputs, signalling function, delayed, with contact (EF003349) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 0
Number of outputs, signalling function, delayed, semiconductors (EF003351) 0
Stop category according to IEC 60204 (EF007498) Other
With approval for BG BIA (EF004145) No
With approval according to UL (EF001783) No
Width (EF000008) 22.5 mm
Height (EF000040) 112 mm
Depth (EF000049) 114.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.