PHOENIX CONTACT PSR-SPP-24DC/MMS/1X1/THY PSR-SPP- 24DC/MMS/1X1/THY 2981693 PHOENIX CONTACT Detector of escalators from two channels up to SIL3 (accor.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSR-SPP- 24DC/MMS/1X1/THY 2981693 PHOENIX CONTACT Detector of escalators from two channels up to SIL3 (accor..

PSR-SPP-24DC/MMS/1X1/THY

2981693

PHOENIX CONTACT

1 Pcs.

Detector of escalators from two channels up to SIL3 (according to IEC 61508), exclusively for the supervision of lower speed and higher with disconnection of escalators manufacturer Thyssen Krupp, suitable for the connection of two initiators, stop category 0, 1 no contact, connection terminal, spring, plug, width: 22.5 mm Two-channel escalator detector up to SIL 2 (according to IEC 61508/EN 62061) and category 3/PL d according to EN ISO 13849-1, exclusively for the monitoring of lower and upper speed with disconnection of escalators from the manufacturer Thyssen Krupp, suitable for the connection of 2 initiators, stop category 0, 1 NO contact, Plug-in spring-loaded terminal block, width: 22.5 mm

Automation > Device for monitoring of safety-related circuits
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Data commercial

Key orderTwo million nine hundred eighty one thousand six hundred ninety three
Packing unit1 pcs
Key sellingDNA24X -
EANFour trillion forty six billion three hundred fifty six million ninety one thousand seven hundred forty nine
Unit weight (excluding packaging)176,800 g
Tariff number tariffNinety million three hundred twenty eight thousand nine hundred
Country of originDE (Germany)

Observation

Restriction of useEMC: class A product, see manufacturer's declaration in the download center

Measures

Width22.5 mm
Height112 mm
Depth114.5 mm

Environmental conditions

Room temperature (service)-10 °C ... 60 °C
Ambient temperature (storage / transport)-40 °C ... 70 °C
Height of fixingmax. 2000 m (via NN)

Data entry

Supply voltage rated control circuit OrS
Rated voltage input OrN24 V DC (PELV)
Input voltage range referred to OrN0,85 ... 1,1
Input current typical with UN70 mA DC
Indication of the operating voltageGreen LED
Circuit protectionProt. surge suppressor Diode
Limitation of voltage ≥ 33 V PTC Resistance
Frequency limit1 kHz

Output data

Type of contact1 firing circuit
Contact MaterialAgNi, + 5 µm Au
Switching voltage maximum250 V AC/DC
Minimum voltage of activation0.1 V AC/DC
Constant current limit2 A (open contact)
Current maximum connection2 A (open contact)
Current minimum closing1 mA
Breaking capacity (resistive load) maximum48 W (24 V DC, t = 0 ms)
75 W (48 V DC, t = 0 ms)
55 W (110 V DC, t = 0 ms)
65 W (220 V DC, t = 0 ms)
500 VA (250 V AC, τ = 0 ms)
Breaking capacity minimum60 mW
Mechanical life1x 10Sevenoperations
Output fuse6 To gL

Outputs notice

Number of outputs2 (MO / fOut)
Voltage24 V DC
Constant current limit100 mA

Overview

Type of relayElectromechanical relay with contacts driving enforced according to en 50205
Type of operation nominalWorking time 100 %
Net weight176,8 g
Position to the mountingdiscretionary
Mounting typeMounting on a rail
Index of protectionIP20
IP54
Degree of protection minimum of the place of assemblyIP54
Color housingyellow

Data connection

Type of connectionConnection by spring
plug-inyes
Core cross-section rigid min.0,2 mm2
Section of conductor rigid max.1.5 mm2
Section of flexible conductor, min.0,2 mm2
Section of flexible conductor max.1.5 mm2
Section of conductor AWG min.Twenty four
Section of conductor AWG max.Sixteen
Length desaislar8 mm

Technical parameters of safety

Stop categoryZero
NameIEC 61508 - high demand
Safety Integrity Level (SIL)Two
NameEN ISO 13849
Performance Level (PL)d
CategoryThree
NameEn 62061
Safety Integrity Level Claim Limit (SIL CL)Two

Standards and specifications

NameLines of flight and air spaces between the circuits
Standards/specificationsDIN EN 50178/VDE 0160
Isolation voltage design250 V
Transient voltage design / insulation4 kV / basic insulation
Pollution degreeTwo
Category surgeII

Environmental Product Compliance

China RoHSSpace of time for the intended use: unlimited = FEUP-e
No dangerous substances above the thresholds

Ratings


ETIM for 2981693 Relays (EC001449)
Feature Name Feature Value
Model (EF000010) Basic device
Suitable for rail mounting (EF003972) Yes
With detachable clamps (EF003340) Yes
Type of electric connection (EF003961) Spring clamp connection
Suitable for monitoring of emergency-stop circuits (EF007268) No
Suitable for monitoring of valves (EF007272) No
Suitable for monitoring of optoelectronic protection equipment (EF007269) No
Suitable for monitoring of tactile sensors (EF007271) No
Suitable for monitoring of magnetic switches (EF007266) No
Suitable for monitoring of proximity switches (EF007267) No
Evaluation inputs (EF008245) Other
With start input (EF003342) No
With muting function (EF004057) No
With feedback circuit (EF003343) No
Number of outputs, safety related, undelayed, with contact (EF003344) 0
Number of outputs, safety related, delayed, with contact (EF003345) 0
Number of outputs, safety related, undelayed, semiconductors (EF003346) 0
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, with contact (EF003348) 0
Number of outputs, signalling function, delayed, with contact (EF003349) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 0
Number of outputs, signalling function, delayed, semiconductors (EF003351) 0
Stop category according to IEC 60204 (EF007498) Other
With approval for BG BIA (EF004145) No
With approval according to UL (EF001783) Yes
Width (EF000008) 22.5 mm
Height (EF000040) 112 mm
Depth (EF000049) 114.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.