PHOENIX CONTACT PSR-MC82-5NO-1NC-1DO-24DC-SP PSR-MC82-5NO-1NC-1DO-24DC-SP 2702383 PHOENIX CONTACT Extension module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSR-MC82-5NO-1NC-1DO-24DC-SP 2702383 PHOENIX CONTACT Extension module

PSR-MC82-5NO-1NC-1DO-24DC-SP

2702383

PHOENIX CONTACT

1 Pcs.

Extension module Extension of contacts to SIL 3, cat. 4, PL e in combination with suitable evaluation equipment, 5 trip circuits, US = 24 V DC, plug-in push-in terminal block

Automation > Device for monitoring of safety-related circuits
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2702383
Packing unit1 pc
Catalog pagePage 259 (C-6-2017)
GTIN4055626145488
Weight per Piece (excluding packing)210.300 g
Custom tariff number85371098
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width17.5 mm
Height116.6 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitudemax. 2000 m (Above sea level)

Power supply

Rated control circuit supply voltage US24 V DC -20 % / +25 %
19.2 V DC ... 30 V DC
Rated control supply current IStyp. 80 mA
Power consumption at UStyp. 1.92 W
Inrush current30 mA (Δt = 7 ms at Us)
Filter time4 ms (at A1 in the event of voltage dips at Us)
max. 1 ms (at A1/A2, test pulse width, blanking pulses/dark test)
5 ms (at A1/A2, test pulse rate, blanking pulses/dark test)
Where test pulse width
max. 1 ms (at A1/A2, test pulse width, switch-on pulses/light test)
10 ms (at A1/A2; test pulse rate; switch-on pulses/light test)
Deactivate switch-on pulses/light tests for safety applications.
Protective circuitSurge protection Suppressor diode
Reverse polarity protection Universal diode

Relay outputs: enabling current path

Output nameEnabling current path
Output descriptionsafety-related N/O contacts
Number of outputs5 (undelayed)
Contact type5 enabling current paths
Contact materialAgSnO2
Switching voltagemin. 5 V AC/DC
max. 24 V DC (Enabling current path 23/24)
max. 250 V AC/DC (all other enabling current paths, observe load curve)
Limiting continuous current6 A (observe derating)
Inrush currentmin. 10 mA
max. 6 A
Sq. Total current64 A2(observe derating)
Switching capacitymin. 50 mW
Switching frequency0.5 Hz
Mechanical service life10x 106cycles
Output fuse10 A gL/gG
6 A gL/gG (for low-demand applications)

Relay outputs: return current/signaling current path

Output nameConfirmation current path
Output descriptionSafety-related N/C contacts
Number of outputs1 (undelayed)
Contact type1 confirmation current path
Contact materialAgSnO
Switching voltagemin. 5 V AC/DC
max. 24 V DC
Limiting continuous current100 mA
Inrush currentmax. 100 mA
min. 10 mA
Switching capacitymin. 50 mW
Switching frequencymax. 0.5 Hz
Mechanical service life10x 106cycles

Alarm outputs

Output descriptionnon-safety-related
Number of outputs1 (digital, PNP)
Voltagetyp. 23 V DC (US- 1 V)
Currentmax. 100 mA
Maximum inrush current500 mA (Δt = 1 ms at Us)
Short-circuit protectionYes

Times

Typical pickup time at US< 50 ms (when controlled via A1/A2)
Typical response time at US< 50 ms
Typical release time at US< 25 ms (when controlled via A1/A2)
Recovery time< 100 ms

General

Relay typeElectromechanical relay with forcibly guided contacts in accordance with EN 50205
Nominal operating mode100% operating factor
Net weight210.3 g
Mounting positionvertical or horizontal
Mounting typeDIN rail mounting
Assembly instructionsSee derating curve
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Housing coloryellow
Status display2 x green LEDs

Connection data

Connection methodSpring-cage connection
pluggableYes
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Safety-related characteristic data

Stop category0
DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)3 (In conjunction with suitable evaluating device)
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)3 (In conjunction with suitable evaluating device)
DesignationEN ISO 13849
Performance level (PL)e (In conjunction with suitable evaluating device)
Category4 (In conjunction with suitable evaluating device)
DesignationEN 62061
Safety Integrity Level Claim Limit (SIL CL)3 (In conjunction with suitable evaluating device)

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Rated insulation voltage250 V AC
250 V AC
Rated surge voltage/insulationBasic insulation 4 kV between all current paths
Basic insulation 4 kV between all current paths and housing
Safe isolation, reinforced insulation 6 kV between input circuits and enabling current paths 33/34, 43/44, and 63/64
Degree of pollution2
Overvoltage categoryIII
Shock15g (In the event of stress caused by shock, contact reactions are possible for up to 6 ms.)
Vibration (operation)10 Hz ...150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.)
ConformanceCE-compliant

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 2702383 Relays (EC001449)
Feature Name Feature Value
Model (EF000010) Expansion device
Suitable for rail mounting (EF003972) Yes
With detachable clamps (EF003340) Yes
Type of electric connection (EF003961) Spring clamp connection
Suitable for monitoring of emergency-stop circuits (EF007268) No
Suitable for monitoring of valves (EF007272) No
Suitable for monitoring of optoelectronic protection equipment (EF007269) No
Suitable for monitoring of tactile sensors (EF007271) No
Suitable for monitoring of magnetic switches (EF007266) No
Suitable for monitoring of proximity switches (EF007267) No
Evaluation inputs (EF008245) Other
With start input (EF003342) No
With muting function (EF004057) No
With feedback circuit (EF003343) No
Release-delay (EF001129) 0.05 s
Number of outputs, safety related, undelayed, with contact (EF003344) 5
Number of outputs, safety related, delayed, with contact (EF003345) 0
Number of outputs, safety related, undelayed, semiconductors (EF003346) 0
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, with contact (EF003348) 1
Number of outputs, signalling function, delayed, with contact (EF003349) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 0
Number of outputs, signalling function, delayed, semiconductors (EF003351) 0
Stop category according to IEC 60204 (EF007498) Other
With approval for BG BIA (EF004145) No
With approval according to UL (EF001783) No
Width (EF000008) 17.5 mm
Height (EF000040) 116.6 mm
Depth (EF000049) 114.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.