PHOENIX CONTACT PSR-MC42-2NO-1DO-24DC-SP PSR-MC42-2NO-1DO-24DC-SP 2702902 PHOENIX CONTACT Safety relay with IO-Link for emergency stop, safety doors .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSR-MC42-2NO-1DO-24DC-SP 2702902 PHOENIX CONTACT Safety relay with IO-Link for emergency stop, safety doors ..

PSR-MC42-2NO-1DO-24DC-SP

2702902

PHOENIX CONTACT

1 Pcs.

Safety relay with IO-Link for emergency stop, safety doors and light grids, up to SILCL 3, Cat. 4, PL e, 2 sensor circuits, automatic or manual, monitored start, 2 enabling current paths, 1 signal output, U Safety relay with IO-Link for emergency stop, safety doors and light curtains up to SIL 3, cat. 4, PL e, 2 sensor circuits, controlled, manual or automatic start, 2 trip circuits, 1 signal output, US = 24 V DC, plug-in push-in terminal block

Automation > Device for monitoring of safety-related circuits
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2702902
Packing unit1 pc
Catalog pagePage 224 (C-6-2019)
GTIN4055626458564
Weight per Piece (excluding packing)180.000 g
Custom tariff number85371098
Country of originDE (Germany)

Drawings



Block diagram

Block diagram

Circuit diagram

Circuit diagram



Back to top

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Back to top

Dimensions

Width17.5 mm
Height116.6 mm
Depth114.5 mm
Back to top

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitude≤ 2000 m (Above sea level)
Back to top

Power supply

DesignationA1/A2
Rated control circuit supply voltage US24 V DC -20 % / +25 % (provide external protection)
Rated control supply current IStyp. 60 mA
Power consumption at UStyp. 1.44 W
Inrush currenttyp. 2.5 A (Δt = 500 µs at Us)
Filter time1 ms (at A1 in the event of voltage dips at Us)
Protective circuitSerial protection against polarity reversal Suppressor diode
Back to top

Supply of the IO-Link ports

DesignationL+/L-
Nominal voltage for I/O supply24 V DC -20 % / +25 % (is provided via the IO-Link interface of the IO-Link master.)
Current consumptiontyp. 16 mA
Type of protectionSerial protection against polarity reversal
Protective circuit/componentSuppressor diode
Back to top

Digital inputs

Input nameSensor circuit S0
S12, S22
Description of the inputsafety-related sensor inputs
NPN (S12), NPN/PNP (S22)
Number of inputs2
Input voltage range "0" signal0 V DC ... 5 V DC (S12)
For S22, see note in “Signal generator connection versions” section.
Input voltage range "1" signal11 V DC ... 30 V DC
Input current range "0" signal0 mA ... 2 mA (S12, S22)
Inrush current< 5 mA (typ. with USat S12, Δt = 150 ms)
< 5 mA (typically with USat S22/24 V, Δt = 500 µs)
> -5 mA (typically with USat S22/0 V, Δt = 500 µs)
Current consumption< 5 mA (Typically with USat S12)
< 5 mA (typically with USat S22/24 V)
> -5 mA (typically with USat S22/0 V)
Filter time1.5 ms (Test pulse width of low test pulses)
Test pulse rate = 5 x Test pulse width
Deactivate switch-on pulses/light tests for safety applications.
Max. permissible overall conductor resistance150 Ω
Concurrence input 1/2
Protective circuit/componentSuppressor diode
Input nameSensor circuit S1
S32, S42
Description of the inputsafety-related sensor inputs
NPN
Number of inputs2
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Input current range "0" signal0 mA ... 2 mA
Inrush current< 20 mA (typically with US)
Current consumption< 5 mA (typically with US)
Filter timemax. 1.5 ms (Test pulse width of low test pulses)
Test pulse rate = 5 x Test pulse width
Deactivate switch-on pulses/light tests for safety applications.
Max. permissible overall conductor resistance150 Ω
Concurrence input 1/2
Protective circuit/componentSuppressor diode
Input nameDiagnostic input
DGN
Description of the inputnon-safety-related
Number of inputs1
Input voltage range0 V DC ... 30 V DC
Current consumptiontyp. 30 mA
Protective circuit/componentSuppressor diode
Input nameStart circuit
S34
Description of the inputNPN (manual start), PNP (autostart)
Number of inputs1
Input voltage range "1" signal19.2 V DC ... 30 V DC (manual start, autostart: 0 V)
Inrush current< 10 mA (typically with US, Δt = 100 ms)
Current consumption< 5 mA (typically with USat S34/24 V)
> -5 mA (typically with USat S34/0 V)
Max. permissible overall conductor resistance150 Ω
Protective circuit/componentSuppressor diode
Back to top

IO-Link inputs

DesignationIO-Link
SpecificationVersion 1.1
Transmission speed230 kbps (COM3)
Cycle Time5 ms
Process data update5 ms
Amount of process datamax. 31 Byte (Input data)
max. 16 Byte (Output data)
Number of ports1
Connection methodSpring-cage connection
Connection technology3-wire
Port typeClass A
Input nameC/Q
Description of the inputIO-Link switching and communication cable
Number of inputs1
Back to top

Relay outputs: enabling current path

Output nameEnabling current path
13/14, 23/24
Output descriptionsafety-related N/O contacts
2 NO contacts each in series, without delay, floating
Number of outputs2 (undelayed)
Contact type2 enabling current paths
Contact materialAgSnO2
Switching voltagemin. 12 V AC/DC
max. 250 V AC/DC (Observe the load curve)
Limiting continuous current6 A
Inrush currentmin. 3 mA
max. 6 A
Sq. Total current72 A2(observe derating)
Switching capacitymin. 60 mW
Switching frequency0.5 Hz
Mechanical service life10x 106cycles
Switching capacity according to IEC 60947-5-14 A (24 V (DC13))
5 A (250 V (AC15))
Output fuse6 A gL/gG
4 A gL/gG (for low-demand applications)
Back to top

Alarm outputs

DesignationM1
Output descriptionPNP
non-safety-related
Number of outputs1
Voltageapprox. 22 V DC (Us- 2 V)
Currentmax. 100 mA
Maximum inrush current500 mA (Δt = 1 ms at Us)
Protective circuit/componentSuppressor diode
Back to top

Times

Typical pickup time at US< 250 ms (when controlled via A1)
Typical response time at US< 220 ms (automatic start)
< 175 ms (manual, monitored start)
Typical release time at US< 20 ms (on demand via the sensor circuit)
< 20 ms (on demand via A1)
Restart time< 1 s (Boot time)
Recovery time< 500 ms
Back to top

General

Relay typeElectromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205)
Nominal operating mode100% operating factor
Net weight150.98 g
Mounting positionvertical or horizontal
Mounting typeDIN rail mounting
Assembly instructionsSee derating curve
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Housing materialPBT
Housing coloryellow
Operating voltage display1 x green, yellow, red LED
Status display5x LED green
Back to top

Connection capacity

Connection methodPush-in spring connection
pluggableYes
Conductor cross section solid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG / kcmil24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Stripping length8 mm
Back to top

Safety-related characteristic data

Stop category0
DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)3
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)3
DesignationEN ISO 13849
Performance level (PL)e (4 A DC13; 5 A AC15; 8760 switching cycles/year)
Category4
DesignationEN 62061
Safety Integrity Level Claim Limit (SIL CL)3
Back to top

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 60947-1
Rated insulation voltage320 V
320 V
Rated surge voltage/insulationBasic insulation 4 kV between all current paths and housing
Safe isolation, reinforced insulation 4 kV between input circuit and enabling current path (13/14) and enabling current path (23/24)
Degree of pollution2
Overvoltage categoryII
Shock15g
Vibration (operation)10 Hz ... 150 Hz, 2g
ConformanceCE-compliant
Back to top

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 5.127371901
eCl@ss 6.027371819
eCl@ss 8.027371819
eCl@ss 9.027371819
Back to top

ETIM

ETIM 5.0EC001449
ETIM 6.0EC001449
ETIM 7.0EC001449
Back to top

ETIM for 2702902 Relays (EC001449)
Feature Name Feature Value
Model (EF000010) Basic device
Suitable for rail mounting (EF003972) Yes
With detachable clamps (EF003340) Yes
Type of electric connection (EF003961) Spring clamp connection
Suitable for monitoring of position switches (EF007270) Yes
Suitable for monitoring of emergency-stop circuits (EF007268) Yes
Suitable for monitoring of valves (EF007272) No
Suitable for monitoring of optoelectronic protection equipment (EF007269) Yes
Suitable for monitoring of tactile sensors (EF007271) No
Suitable for monitoring of magnetic switches (EF007266) Yes
Suitable for monitoring of proximity switches (EF007267) No
Evaluation inputs (EF008245) Other
With start input (EF003342) No
With muting function (EF004057) No
With feedback circuit (EF003343) Yes
Release-delay (EF001129) 0.22 s
Number of outputs, safety related, undelayed, with contact (EF003344) 2
Number of outputs, safety related, delayed, with contact (EF003345) 0
Number of outputs, safety related, undelayed, semiconductors (EF003346) 0
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, with contact (EF003348) 0
Number of outputs, signalling function, delayed, with contact (EF003349) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 0
Number of outputs, signalling function, delayed, semiconductors (EF003351) 0
Stop category according to IEC 60204 (EF007498) Other
With approval for BG BIA (EF004145) No
With approval according to UL (EF001783) No
Width (EF000008) 17.5 mm
Height (EF000040) 116.6 mm
Depth (EF000049) 114.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.