PHOENIX CONTACT PS-EE-2G/1AC/24DC/75W/SC PS-EE-2G/1AC/24DC/75W/SC 1234301 PHOENIX CONTACT Primary switching power supplies, ESSENTIAL POWER, Screw co.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PS-EE-2G/1AC/24DC/75W/SC 1234301 PHOENIX CONTACT Primary switching power supplies, ESSENTIAL POWER, Screw co..

PS-EE-2G/1AC/24DC/75W/SC

1234301

PHOENIX CONTACT

1 Pcs.

Primary switching power supplies, ESSENTIAL POWER, Screw connection, Rail mounting, input: 1 phase, output: 24 V DC / 3,125 A, adjustable from 24 V DC ... 28 V DC Primary Switching Power Supplies, ESSENTIAL POWER, Screw Connection, Rail Mount, Input: 1 Phase, Output: 24 V DC / 3.125 A Primary-switched power supply unit, ESSENTIAL POWER, Screw connection, DIN rail mounting, input: 1-phase, output: 24 V DC / 3.125 A, adjustable from 24 V DC ... 28 V DC

Automation > DC-power supply

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Input data
AC operation
Supply system configurationTN, TT, IT (PE)
Nominal input voltage range100 V AC ... 240 V AC
Input voltage range110 V AC ... 240 V AC ±10 % (PN= 75 W)
100 V AC ... 109 V AC -15 % ... +10 % (PN= 63 W)
Typical national grid voltage120 V AC
230 V AC
Voltage type of supply voltageAC
Inrush currenttyp. 27 A (at 25 °C)
Inrush current integral (I2t)typ. 0.6 A2s
Frequency range (fN)50 Hz ... 60 Hz ±10 %
Mains buffering timetyp. 14 ms (120 V AC)
typ. 70 ms (230 V AC)
Current consumptionmax. 1.5 A (75 W)
max. 1.5 A (63 W)
typ. 1.3 A (110 V AC (75 W))
typ. 0.75 A (240 V AC (75 W))
typ. 1.2 A (100 V AC (63 W))
typ. 1.1 A (109 V AC (63 W))
Protective circuitTransient protection; Varistor
Switch-on timetyp. 1 s
Device mains fuse3.15 A internal (device protection), fast-blow
Recommended breaker for input protection6 A ... 16 A (Characteristic B, C, D, K or comparable)
Discharge current to PE< 3.5 mA

Output data
Efficiencytyp. 88 % (120 V AC)
typ. 89 % (230 V AC)
Nominal output voltage24 V DC
Setting range of the output voltage (USet)24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)max. 3.125 A (PN= 75 W)
max. 2.62 A (PN= 63 W)
Short-circuit-proofyes
No-load proofyes
Crest factortyp. 3 (120 V AC)
typ. 4 (230 V AC)
Output power (PN)75 W (240 V AC)
63 W (100 V AC)
Connection in parallelyes, for increasing power and redundancy with diode
Connection in seriesyes, for increased output voltage
Feedback voltage resistance≤ 35 V DC
Protection against overvoltage at the output (OVP)≤ 35 V DC
Residual rippletyp. 50 mVPP(with nominal values)
Control deviation< 2 % (change in load, static 10 % ... 90 %)
< 4 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Rise time< 100 ms (UOut= 10 % ... 90 %)
Minimum no-load power dissipation< 1 W (120 V AC)
Maximum no-load power dissipation< 1 W (230 V AC)
Minimum nominal load power dissipation< 11 W (120 V AC)
Power loss nominal load max.< 9 W (230 V AC)
Integrated fuse protectionno

Connection data
Input
Position1.x
Identification1.1 (), 1.2 (L), 1.3 (N)
Conductor connection
Connection methodScrew connection
rigid0.5 mm² ... 2.5 mm²
flexible0.5 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve0.5 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve0.5 mm² ... 2.5 mm²
rigid (AWG)20 ... 14 (Cu)
Stripping length6.5 mm
Tightening torque0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
Drive form screw headSlotted L
Output
Position2.x
Identification2.1, 2.2 (+), 2.3, 2.4 (-)
Conductor connection
Connection methodScrew connection
rigid0.5 mm² ... 2.5 mm²
flexible0.5 mm² ... 2.5 mm²
flexible with ferrule without plastic sleeve0.5 mm² ... 2.5 mm²
flexible with ferrule with plastic sleeve0.5 mm² ... 2.5 mm²
rigid (AWG)20 ... 14 (Cu)
Stripping length6.5 mm
Tightening torque0.5 Nm ... 0.6 Nm
5 lbf-in. ... 7 lbf-in.
Drive form screw headSlotted L

Signaling
LED signaling
Types of signalingLED DC OK – signal state operation (UN= 24 V DC, IOut= IN)
FunctionVisual operating state display
Colorgreen
LED offSupply voltage input AC not present (Off)
LED on (green), DC OKUOUT> 17.5 V (On (green), DC OK)

Electrical properties
Number of phases1.00
Insulation voltage input/output4 kV AC (type test)
3 kV AC (routine test)
Insulation voltage input / PE3.5 kV AC (type test)
2.4 kV AC (routine test)

Product properties
Product typePower supply
Product familyESSENTIAL POWER
MTBF (Telcordia SR-332)> 2800000 h (25 °C)
> 2300000 h (40 °C)
> 2100000 h (45°C)
Insulation characteristics
Protection classII
Degree of pollution2
Life expectancy (electrolytic capacitors)
Current3.15 A
Temperature40 °C
Time28000 h
Additional text120 V AC
Life expectancy (electrolytic capacitors)
Current3.15 A
Temperature30 °C
Time57000 h
Additional text120 V AC
Life expectancy (electrolytic capacitors)
Current3.15 A
Temperature40 °C
Time50000 h
Additional text230 V AC
Life expectancy (electrolytic capacitors)
Current3.15 A
Temperature30 °C
Time100000 h
Additional text230 V AC

Dimensions
Item dimensions
Width33 mm
Height90 mm
Depth100 mm
Installation dimensions
Installation distance right/left10 mm / 10 mm
Installation distance top/bottom30 mm / 30 mm

Mounting
Mounting typeDIN rail mounting
Assembly instructionsalignable: 0 mm horizontally, 30 mm vertically
Mounting positionhorizontal DIN rail NS 35, EN 60715
With protective coatingNo

Material specifications
Housing materialPlastic
Hood versionStainless steel
Side element versionAluminum
Foot latch materialPolyamid
Housing materialPolycarbonate

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-20 °C ... 70 °C (Derating >45°C: 2.5%/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)
Climatic class3K22 (in accordance with EN 60721-3-3)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock (operation)15 ms, 15 g, per spatial direction (IEC 60068-2-27)
Vibration (operation)10 Hz ... 50 Hz, amplitude ±0.2 mm
50 Hz to 150 Hz, 2.3 g, 90 min.

Standards and regulations
Overvoltage category
EN 61010-1II (≤ 3000 m)
Electrical safety
Standard designationElectrical safety
Standards/specificationsIEC 61010-2-201 (SELV)
Safety for measurement, control, and laboratory equipment
Standard designationSafety for equipment for measurement, control, and laboratory use
Standards/specificationsIEC 61010-1
Protective extra-low voltage
Standard designationProtective extra-low voltage
Standards/specificationsIEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Limitation of harmonic line currents
Standard designationLimitation of harmonic line currents
Standards/specificationsEN 61000-3-2
Mains voltage dips
Standard designationRequirement of the semiconductor industry with regard to mains voltage dips
Standards/specificationsSEMI F47 - 0706 (185 V AC)

Approvals
UL
IdentificationUL/C-UL Listed UL 61010-1
UL
IdentificationUL/C-UL Listed UL 61010-2-201
CB scheme
IdentificationCB scheme (IEC 61010-1, IEC 61010-2-201)

EMC data
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
Interference emissionInterference emission in accordance with EN 61000-6-3 (residential and commercial) and EN 61000-6-4 (industrial)
EMC requirements for noise immunityEN 61000-6-2
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Conducted noise emissionEN 55016
EN 61000-6-3 (Class B)
Noise emissionEN 55016
EN 61000-6-3 (Class B)
Harmonic currents
Standards/regulationsEN 61000-3-2
EN 61000-3-2 (Class A)
Frequency range0 kHz ... 2 kHz
Electrostatic discharge
Standards/regulationsEN 61000-4-2
Electrostatic discharge
Contact discharge6 kV (Test Level 3)
Discharge in air8 kV (Test Level 3)
CommentsCriterion A
Electromagnetic HF field
Standards/regulationsEN 61000-4-3
Electromagnetic HF field
Test field strength10 V/m (Test Level 3)
Frequency range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
Frequency range2 GHz ... 3 GHz
Test field strength1 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)
Standards/regulationsEN 61000-4-4
Fast transients (burst)
Input4 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 3 - asymmetrical)
CommentsCriterion A
Surge voltage load (surge)
Standards/regulationsEN 61000-4-5
Input2 kV (Test Level 4 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output0.5 kV (Test Level 2 - symmetrical)
1 kV (Test Level 3 - asymmetrical)
CommentsCriterion A
Conducted interference
Standards/regulationsEN 61000-4-6
Conducted interference
Input/Outputasymmetrical
Frequency range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)
Voltage dips
Standards/regulationsEN 61000-4-11
Voltage230 V AC
Frequency50 Hz
Voltage dip70 %
Number of periods25 periods
CommentsCriterion A
Voltage dip40 %
Number of periods10 periods
CommentsCriterion A
Voltage dip0 %
Number of periods1 period
CommentsCriterion A
Criteria
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.
Criterion CTemporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.

ETIM for 1234301 Low-voltage industrial controls and switchgear (EC002540)
Feature Name Feature Value
Voltage type (supply voltage) (EF002991) AC
1st secondary output voltage (EF006792) 24 V
Max. output current 1 (EF008284) 3.125 A
Secondary voltage adjustable (EF007002) Yes
Nominal value output voltage 1 (EF009393) 24 V
Nominal value output current 1 (EF009396) 3.125 A
Short-circuit-proof (EF007332) Yes
Rated supply voltage AC 50 Hz (EF007076) 85 V
Rated supply voltage AC 60 Hz (EF007077) 85 V
Output voltage stabilized (EF003092) Yes
Power output (EF003034) 75 W
Stabilized (EF005302) Yes
Type of electric connection (EF003961) Screw connection
Suitable for rail mounting (EF003972) Yes
Wall mounting possible (EF003973) No
Modular version (EF001126) No
Built-in height (EF000332) 90 mm
Direct mounting possible (EF005689) No
Width (EF000008) 33 mm
Height (EF000040) 90 mm
Depth (EF000049) 100 mm
Suitable for safety functions (EF001597) Yes
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Degree of protection (IP) (EF005474) IP20
Degree of protection (NEMA) (EF011959) Other

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.