PHOENIX CONTACT RIF-1-RPT-LDP-24DC/2X21AU RIF-1-RPT-LDP-24DC/2X21AU 2903330 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

RIF-1-RPT-LDP-24DC/2X21AU 2903330 PHOENIX CONTACT Relay Module

RIF-1-RPT-LDP-24DC/2X21AU

2903330

PHOENIX CONTACT

10 Pcs.

Relay Module Pre-assembled relay module with push-in connection, consisting of: relay socket, relay with multi-layer universal contact, plug-in indication/anti-parasitic module and clamping flange. Contact type: 2 investor contacts. Input voltage: 24 V DC

Automation > Switching relay
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2903330
Packing unit10 pc
Minimum order quantity10 pc
Catalog pagePage 341 (C-5-2017)
GTIN4046356732314
Weight per Piece (excluding packing)67.700 g
Custom tariff number85364110
Country of originDE (Germany)

Note

Utilization restriction1
Type of noteNotes on operation
NoteFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)

Dimensions

Width16 mm
Height93 mm
Depth75 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN24 V DC
Input voltage range in reference to UNsee diagram
Typical input current at UN18 mA
Typical response time8 ms
Typical release time10 ms
Coil voltage24 V DC
Protective circuitDamping diode
Operating voltage displayYellow LED
Power dissipation for nominal condition0.43 W

Contact side

Contact type2 PDT
Type of switch contactSingle contact
Contact materialAgNi, hard gold-plated
Maximum switching voltage30 V AC
36 V DC
Minimum switching voltage100 mV (at 10 mA)
Min. switching current1 mA (at 24 V)
Maximum inrush current50 mA
Limiting continuous current50 mA
Interrupting rating (ohmic load) max.1.2 W (at 24 V DC)

Contact side (with destroyed gold layer)

Contact materialAgNi
Notethe following values are applicable if a gold layer is destroyed
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V (at 10 mA)
Limiting continuous current25 A (20 ms, N/O contact)
Min. switching current10 mA (At 5 V)
Interrupting rating (ohmic load) max.192 W (at 24 V DC)
96 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
57 W (at 220 V DC)
2000 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
2 A (at 24 V, AC15)
2 A (at 120 V, AC15)
2 A (at 250 V, AC15)

Connection data 1

Connection nameCoil side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG26 ... 16 (solid)
26 ... 16 (flexible)

Connection data 2

Connection nameContact side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG26 ... 16 (solid)
26 ... 16 (flexible)

General

Type of noteNotes on operation
NoteFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)
Test voltage relay winding/relay contact4 kVrms(50 Hz, 1 min.)
Test voltage PDT/PDT2.5 kVrms(50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionIP20 (Relay base)
RT III (Relay)
Mechanical service lifeapprox. 3x 107cycles
Service life, electricalsee diagram
Mounting positionany
Assembly instructionsIn rows with zero spacing
Net weight (SAP)67.7 g

Standards and Regulations

Standards/regulationsDIN EN 50178
Rated surge voltage6 kV
InsulationSafe isolation, basic insulation, and 4 kV rated surge voltage between all changeover contacts.
Degree of pollution2
Overvoltage categoryIII
Flammability rating according to UL 94V2

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Articles in set

Classifications


ETIM for 2903330 Relays (EC001437)
Feature Name Feature Value
Type of electric connection (EF003961) Other
Complete with socket (EF003359) Yes
With detachable clamps (EF003340) No
With LED indication (EF005950) Yes
Rated control supply voltage DC (EF003980) 19.2 V
Voltage type for actuating (EF008242) DC
Drive, polarization (EF003355) Polarized
Drive, switching attitude (EF003356) Mono stable
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 2
Type of switch contact (EF003358) Single contact
With forced-guided contacts (EF003357) No
Material of contact insert (EF008521) Other
Material of contact surface (EF004020) Gold
Nominal current (EF000001) 0.018 A
Degree of protection (IP) (EF005474) IP20
Width (EF000008) 16 mm
Height (EF000040) 96 mm
Depth (EF000049) 75 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.