PHOENIX CONTACT PLC-RPT-24DC/21/EX PLC-RPT-24DC/21/EX 2909528 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PLC-RPT-24DC/21/EX 2909528 PHOENIX CONTACT Relay Module

PLC-RPT-24DC/21/EX

2909528

PHOENIX CONTACT

10 Pcs.

Relay Module PLC-INTERFACE, consisting of a base terminal block for mounting on a 6.2 mm rail with push-in connection and plug-in miniature relay with 6 A power contact, 1 switch, input voltage of 24 V DC. Certified according to ATEX/IECEx (zone 2) and Zone Ex class I, div. 2. PLC-INTERFACE, consisting of DIN-rail-mountable basic terminal block in 6.2 mm with Push-in connection and plug-in miniature relay with 6 A power contact, 1 changeover contact, 24 V DC input voltage. Approved in accordance with ATEX/IECEx (zone 2) and Ex zone Class I, Div. 2.

Automation > Switching relay
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
Utilization restriction
EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties
Product typeRelay Module
Product familyPLC-INTERFACE
ApplicationUniversal
potentially explosive areas
Operating mode100% operating factor
Mechanical service life2x 107cycles
Data management status
Date of last data management09.07.2024
Article revision03
Insulation characteristics: Standards/regulations
Overvoltage categoryIII
Pollution degree3

Electrical properties
Maximum power dissipation for nominal condition0.22 W
Test voltage (Winding/contact)4 kV AC (50 Hz, 1 min., winding/contact)

Input data
Coil side
Nominal input voltage UN24 V DC
Input voltage range18.5 V DC ... 33.6 V DC (20 °C)
Nominal voltage (plugged-in electromechanical relay)24 V DC
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN9 mA
Typical response time5 ms
Typical release time8 ms
Protective circuitReverse polarity protection; Polarity protection diode
Surge protection; Freewheeling diode
Operating voltage displayYellow LED

Output data
Switching
Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact connection typePower contact
Contact materialAgSnO
Maximum switching voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage5 V AC/DC (100 mA)
Limiting continuous current6 A
Maximum inrush current10 A (4 s)
Min. switching current10 mA (12 V)
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15)

Connection data
Connection methodPush-in connection
Stripping length10 mm
Conductor cross section rigid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14

Dimensions
Width6.2 mm
Height80 mm
Depth94 mm

Material specifications
Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)

Environmental and real-life conditions
Ambient conditions
Degree of protection (Relay)RT III (Relay)
Degree of protection (Relay base)IP20 (Relay base)
Ambient temperature (operation)-40 °C ... 70 °C (UL)
-40 °C ... 70 °C (ATEX / IECEx)
Ambient temperature (storage/transport)-40 °C ... 85 °C

Approvals
CE
CertificateCE-compliant
ATEX
Identification II 3G Ex ec nC IIC T4 Gc
CertificateIBExU16ATEXB015 X
IECEx
IdentificationEx ec nC IIC T4 Gc
CertificateIECEx IBE 16.0029X
UKCA Ex (UKEX)
Identification II 3 G Ex ec nC IIC T4 Gc
CertificatePxCIF21UKEX2909514X
UL, USA
IdentificationClass I, Zone 2, AEx nA nC IIC T6
UL, USA/Canada
IdentificationClass I, Div. 2, Groups A, B, C, D
UL, Canada
IdentificationClass I, Zone 2, Ex nA nC IIC Gc T6 X
Shipbuilding approval
CertificateTAE0000196
Corrosive gas test
IdentificationISA-S71.04. G3 Harsh Group
EN 60068-2-60
DNV GL data
TemperatureD
HumidityA
VibrationB/C
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data
Electromagnetic compatibilityConformance with EMC directive
Low Voltage DirectiveConformance with Low Voltage Directive

Standards and regulations
Standards/regulations
Standards/regulationsIEC 60947-5-1
EN 60079-0
EN 60079-7
EN 60079-15

Mounting
Mounting typeDIN rail mounting
Assembly notein rows with zero spacing
Mounting positionany

ETIM for 2909528 Relays (EC001437)
Feature Name Feature Value
Type of electric connection (EF003961) Other
Complete with socket (EF003359) Yes
With detachable clamps (EF003340) No
With LED indication (EF005950) Yes
Rated control supply voltage DC (EF003980) 18.5 V
Voltage type for actuating (EF008242) DC
Drive, polarization (EF003355) Polarized
Drive, switching attitude (EF003356) Mono stable
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 1
Type of switch contact (EF003358) Single contact
With forced-guided contacts (EF003357) No
Material of contact insert (EF008521) Other
Material of contact surface (EF004020) Untreated
Nominal current (EF000001) 0.009 A
Degree of protection (IP) (EF005474) IP20
Width (EF000008) 6.2 mm
Height (EF000040) 80 mm
Depth (EF000049) 94 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.