PHOENIX CONTACT PLC-RPT-24DC/21-21/EX PLC-RPT- 24DC/21-21/EX 2909514 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PLC-RPT- 24DC/21-21/EX 2909514 PHOENIX CONTACT Relay Module

PLC-RPT-24DC/21-21/EX

2909514

PHOENIX CONTACT

10 Pcs.

Relay Module PLC-INTERFACE, consisting of a base terminal block for mounting on a 14 mm rail with push-in connection and plug-in relay with power contact, 2 switched contacts, input voltage 24 V DC. Approved according to ATEX/IECEx (zone 2) and Ex zone class I, div. 2.

Automation > Switching relay
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2909514
Packing unit10 pc
Minimum order quantity10 pc
Catalog pagePage 458 (C-5-2017)
GTIN4055626363172
Weight per Piece (excluding packing)64.130 g
Custom tariff number85364190
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width14 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (UL)
-40 °C ... 60 °C (ATEX / IECEx)
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN24 V DC
Typical input current at UN18 mA
Typical response time8 ms
Typical release time10 ms
Protective circuitReverse polarity protection Polarity protection diode
Free-wheeling diode Damping diode
Operating voltage displayYellow LED
Power dissipation for nominal condition0.43 W

Contact side

Contact type2 PDT
Type of switch contactSingle contact
Contact materialAgNi
Maximum switching voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage5 V AC/DC (at 10 mA)
Min. switching current10 mA (At 5 V)
Maximum inrush current15 A (300 ms)
Limiting continuous current6 A
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
85 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
60 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
0.2 A (at 250 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 250 V, AC15)

General

Test voltage relay winding/relay contact4 kV AC (50 Hz, 1 min.)
Test voltage PDT/PDT2.5 kV AC (50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionRT III (Relay)
IP20 (Relay base)
Mechanical service life3x 107cycles
ATEX II 3G Ex ec nC IIC T4 Gc
EU-type examination certificateIBExU16ATEXB015 X
IECExEx ec nC IIC T4 Gc
IECEx certificateIECEx IBE 16.0029X
UL, USAClass I, Zone 2, AEx nA nC IIC T6
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D
UL, CanadaClass I, Zone 2, Ex nA nC IIC Gc T6 X
Mounting positionany
Assembly instructionsIn rows with zero spacing
Net weight (SAP)64.13 g

Connection data input side

Connection nameCoil side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² ()
2x 0.5 mm² ... 1 mm² ()
Conductor cross section AWG26 ... 14

Connection data output side

Connection nameContact side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² ()
2x 0.5 mm² ... 1 mm² ()
Conductor cross section AWG26 ... 14

Standards and Regulations

DesignationStandards/regulations
Standards/regulationsIEC 60664
EN 50178
EN 60079-0, -7, -15
Rated insulation voltage250 V AC
Rated surge voltage6 kV
InsulationSafe isolation, reinforced insulation
Degree of pollution2
Overvoltage categoryIII
Flammability rating according to UL 94V0
ConformanceCE-compliant
ATEX II 3G Ex ec nC IIC T4 Gc
IECExEx ec nC IIC T4 Gc
UL, USAClass I, Zone 2, AEx nA nC IIC T6
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D
UL, CanadaClass I, Zone 2, Ex nA nC IIC Gc T6 X

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 2909514 Relays (EC001437)
Feature Name Feature Value
Type of electric connection (EF003961) Other
Complete with socket (EF003359) Yes
With detachable clamps (EF003340) No
With LED indication (EF005950) Yes
Rated control supply voltage DC (EF003980) 20.2 V
Voltage type for actuating (EF008242) DC
Drive, polarization (EF003355) Polarized
Drive, switching attitude (EF003356) Mono stable
Number of contacts as normally closed contact (EF008255) 0
Number of contacts as normally open contact (EF008256) 0
Number of contacts as change-over contact (EF008257) 2
Type of switch contact (EF003358) Single contact
With forced-guided contacts (EF003357) No
Material of contact insert (EF008521) Other
Material of contact surface (EF004020) Untreated
Nominal current (EF000001) 0.018 A
Degree of protection (IP) (EF005474) IP20
Width (EF000008) 14 mm
Height (EF000040) 80 mm
Depth (EF000049) 94 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.