PHOENIX CONTACT PLC-BPT-230AC/21HC/SO46/HI PLC-BPT-230AC/21HC/SO46/HI 1079400 PHOENIX CONTACT 14 mm PLC basic terminal block for high continuous curren.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PLC-BPT-230AC/21HC/SO46/HI 1079400 PHOENIX CONTACT 14 mm PLC basic terminal block for high continuous curren..

PLC-BPT-230AC/21HC/SO46/HI

1079400

PHOENIX CONTACT

10 Pcs.

14 mm PLC basic terminal block for high continuous currents, resistant to interference voltages of up to 190 V AC, thanks to defined activation and deactivation thresholds with Push-in connection, without relay, for mounting on DIN rail NS 35/7,5, 1 changeover contact, input voltage of 230 V AC 14 mm PLC base terminal block for high constant currents, insensitive to eddy currents up to 190 V AC thanks to defined connection and disconnection thresholds with push-in connection, without relay equipment, for DINNS 35/7.5 rail mounting, 1 switch, input voltage 230 V AC

Automation > Relay socket
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1079400
Packing unit1
GTIN4055626797397
Custom tariff number85366990

Dimensions

Width14 mm
Height80 mm
Depth94 mm
Back to top

Ambient conditions

Ambient temperature (operation)-40 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Back to top

Input data

Nominal input voltage UN230 V AC
Input voltage range in reference to UN0.83 ... 1.1 (at 20 °C)
Typical response time7 ms
Typical release time20 ms
Status displayLED
Protective circuitBridge rectifier Bridge rectifier
RCZ filter RCZ filter
Back to top

General

Protective circuitBridge rectifier Bridge rectifier
RCZ filter RCZ filter
Colorgray
Operating mode100% operating factor
Mounting positionany
Assembly instructionsIn rows with zero spacing
Back to top

Connection data

Connection nameCoil side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14
Back to top

Connection data 2

Connection nameContact side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG26 ... 14
Back to top

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Back to top

Classifications

eCl@ss

eCl@ss 8.027371603
eCl@ss 9.027371603
Back to top

ETIM

ETIM 5.0EC001456
ETIM 6.0EC001456
ETIM 7.0EC001456
Back to top

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.