View larger
ANT-DIR-868-01
2702137
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Note on application | |
| Note on application | Only for industrial use |
| Utilization restriction | |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
| Product type | Antenna |
| Scope of delivery | included mounting bracket and mast clamps |
| Radiation characteristics | Directional |
| Gain | 3.5 dBi |
| Vertical beamwidth | 90 ° |
| Horizontal beamwidth | 135 ° |
| Polarization | Circular clockwise |
| Data management status | |
| Article revision | 00 |
| Frequency band | 868 MHz |
| Frequency range | 868 MHz ... 870 MHz |
| Impedance | 50 Ω |
| Maximum capacity | 10.00 W |
| Connection technology | |
| Connection method | N (female) |
| Outside diameter | 25 mm ... 85 mm (Mast) |
| Safety data | |
| Input voltage Ui | 30 V |
| Input current Ii | 600 mA |
| Input power Pi | ≤ 1 W (30 dB) |
| Max. internal inductance Li | negligible |
| Capacitance Ci | negligible |
| Dimensional drawing | ![]() |
| Width | 80 mm |
| Height | 100 mm |
| Length | 35 mm |
| External dimensions | |
| Outside diameter | 25 mm ... 85 mm (Mast) |
| Material (Radom) | Lexan EXL 9330 |
| Material (Holder) | Stainless steel V2A |
| Material (Mast clamp) | Stainless steel V2A |
| Flammability rating according to UL 94 | V0 |
| Other resistance | salt water resistant |
| Ambient conditions | |
| Degree of protection | IP67 |
| Impact strength | IK06 |
| Ambient temperature (operation) | -40 °C ... 75 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Wind velocity | 220 km/h |
| CE | |
| Certificate | CE-compliant |
| ATEX | |
| Identification | II 1G Ex ia IIC T6 Ga |
| Certificate | IBExU14 ATEX1116X |
| Note | Please follow the special installation instructions in the documentation! |
| IECEx | |
| Identification | Ex ia IIC T6 Ga |
| Certificate | IBE 14.0039X |
| Electronic devices in rail vehicles | |
| Shock (operation) | In accordance with EN 50125-3, positioning profile: “away from the rails” |
| Vibration (operation) | In accordance with EN 50125-3, positioning profile: “away from the rails” |
| Other resistance | salt water resistant |
| Standards/specifications | EN 60079-0 |
| EN 60079-11 | |
| EN 60079-26 | |
| Note | Explosion protection |
| Standards/specifications | EN 50155 |
| Note | Railway application |
| Standards/specifications | EN 45545-2 |
| NFPA 130 | |
| BS 6853 | |
| Note | Fire protection on railway vehicles |
| Mounting type | Wall mounting |
| Mast mounting | |
| Assembly note | Outdoors and indoors |
| Feature Name | Feature Value |
|---|---|
| Indoor (EF004788) | Yes |
| Outdoor (EF005158) | Yes |
| Beam angle horizontal (EF009701) | 135 ° |
| Beam angle vertical (EF009702) | 90 ° |
| With connection cable (EF005036) | No |
| Mounting method (EF000003) | Wall mounting |
| Height (EF000040) | 100 mm |
| Width (EF000008) | 80 mm |
| Depth (EF000049) | 35 mm |
| Degree of protection (IP) (EF005474) | IP67 |
| Ambient temperature during operating (EF007515) | -40 °C |