| Cable length | 5 m |
| CAT5 Flexible Ethernet, 2 Pairs [93E] |
| Dimensioned drawing | |
| Sheath Weight | 42 kg/km |
| Style UL AWM | 20963 (80 °C / 30 V) |
| Cable Standards/Specifications | Electrical requirements EN 50288-2-2 |
| Number of poles | 4 |
| Armored | Yes |
| Type | CAT5 Flexible Ethernet, 2 Pairs [93E] |
| Conductor Structure | 2x2xAWG26/7, SF/UTP |
| Signal travel time | 5.3 ns/m |
| Conductor structure signal line | 7x 0.16 mm |
| AWG Signal Line | 26 |
| Cable section | 2x 2x 0.14 mm² |
| Wire diameter with insulation | 0.98 mm |
| Outer diameter of the cable | 6.4 mm ±0.2 mm |
| Outer Sheath, Material | PURE |
| Outer sheath, colour | lagoon blue RAL 5021 |
| Conductive material | Bare Cu Cord |
| Wire Insulating Material | Foamed PE |
| Yarn, colour | white/orange-orange, white/green-green |
| Outer sheath thickness | 1.2 mm |
| Pair Wiring | 2 threads per pair |
| Total wiring | 2 pairs with 2 filling masses in the direction of the core |
| Shielding Optical Coating | 70 % |
| Insulation resistance | ≥ 500 MΩ*km |
| Bond Resistance | ≤ 100.00 mΩ/m (for 10 MHz) |
| Loop Resistor | ≤ 290.00 Ω/km |
| Wave Impedance | 100 Ω ±5 Ω (for 100 MHz) |
| Line capacity | approx. 45 nF/km (at 1 kHz) |
| Rated cable voltage | ≤ 100 V (Peak value, par for high currents) |
| Wire/Wire Test Voltage | 700 V (50 Hz, 1 min.) |
| Wire/shielding test voltage | 700 V (50 Hz, 1 min.) |
| Cable Load Capacity | 2 A (according to DIN VDE 0891-1) |
| Minimum bending radius, fixed position | 4 x D |
| Minimum bend radius, flexible position | 8 x D |
| Minimum bending radius, fixed installation | 26 mm |
| Minimal bending radius, flexible installation | 52 mm |
| Tensile strength | ≤ 80 N |
| Para-Speech Impairment (NEXT) | 65.3 dB (at 1 MHz) |
| 56.3 dB (at 4 MHz) |
| 50.3 dB (for 10 MHz) |
| 47.2 dB (at 16 MHz) |
| 45.8 dB (at 20 MHz) |
| 42.9 dB (at 31.25 MHz) |
| 38.4 dB (at 62.5 MHz) |
| 35.3 dB (at 100 MHz) |
| Cumulative crosstalk (PSNEXT) | 62.3 dB (at 1 MHz) |
| 53.3 dB (at 4 MHz) |
| 47.3 dB (at 10 MHz) |
| 44.2 dB (at 16 MHz) |
| 42.8 dB (at 20 MHz) |
| 39.9 dB (at 31.25 MHz) |
| 35.4 dB (at 62.5 MHz) |
| 32.3 dB (at 100 MHz) |
| Regularity Impairment (RL) | 23 dB (at 4 MHz) |
| 24.1 dB (at 8 MHz) |
| 25 dB (for 10 MHz) |
| 25 dB (for 16 MHz) |
| 25 dB (for 20 MHz) |
| 23.6 dB (at 31.25 MHz) |
| 21.5 dB (at 62.5 MHz) |
| 20.1 dB (at 100 MHz) |
| Screen effect | 3.2 dB (at 1 MHz) |
| 6 dB (for 4 MHz) |
| 9.5 dB (for 10 MHz) |
| 12.1 dB (at 16 MHz) |
| 13.6 dB (at 20 MHz) |
| 17.1 dB (at 31.25 MHz) |
| 24.8 dB (at 62.5 MHz) |
| 32 dB (at 100 MHz) |
| Halogen-free | according to IEC 60754-1 |
| Resistance to flame spread | according to IEC 60332-1-2 |
| according to UL VW1 standard |
| according to UN ECE-R 118.03 |
| Oil resistance | according to EN 60811-2-1 |
| Ambient Temperature (Operating) | -40 °C ... 80 °C (cable, fixed installation) |
| -20 °C ... 80 °C (Cable, Flexible Laying) |
| Ambient temperature (mounting) | -20 °C ... 80 °C |