PHOENIX CONTACT PLC-APT-PT100-IN PLC-APT-PT100-IN 2906919 PHOENIX CONTACT Extension module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PLC-APT-PT100-IN 2906919 PHOENIX CONTACT Extension module

PLC-APT-PT100-IN

2906919

PHOENIX CONTACT

1 Pcs.

Extension module Pt 100/Pt 1000 temperature converter for PLC logic modules (generation 2 only), single-channel, signal type (Pt 100, Pt 1000) configurable via DIP switch, push-in connection

Automation > PLC analogue I/O-module
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2906919
Packing unit1 pc
Catalog pagePage 431 (C-5-2017)
GTIN4055626155500
Weight per Piece (excluding packing)50.300 g
Custom tariff number85389099
Country of originDE (Germany)

Dimensions

Width6.2 mm
Height80 mm
Depth86 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 50 °C
Ambient temperature (storage/transport)-20 °C ... 70 °C

Supply

Rated control circuit supply voltage US24 V DC
Rated control supply voltage range with reference to US0.8 ... 1.1
Rated control supply current IS14 mA
Type of protectionReverse polarity protection
Surge protection
Operating voltage displayGreen LED
IndicationRed LED

Input data

Input nameAnalog input resistance
Sensor types (RTD) that can be usedPt 100 (IEC 60751, α = 0,00385)
Connection technology2-wire
Sensor input current~ 900 µA
Maximum temperature coefficient0.01 %/K
Temperature measuring range-50 °C ... 200 °C
Maximum transmission error1 %
Surge voltage protection> 33 V
Input nameAnalog input resistance
Sensor types (RTD) that can be usedPt 1000 (IEC 60751, α = 0.00385)
Connection technology2-wire
Sensor input current~ 900 µA
Maximum temperature coefficient0.01 %/K
Temperature measuring range-50 °C ... 200 °C
Maximum transmission error1 %
Surge voltage protection> 33 V

Output data

Output nameDigital output

General

Operating mode100% operating factor
Degree of protectionIP20
Mounting positionany
Assembly instructionsIn rows with zero spacing

Connection data

Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14
Number of connections4

Standards and Regulations

DesignationAir clearances and creepage distances
Standards/regulationsDIN EN 50178
Rated insulation voltage50 V
Rated surge voltage0.5 kV
InsulationBasic insulation
Degree of pollution2
Overvoltage categoryIII
ConformanceCE-compliant
UL, USA/CanadaUL 508 Listed

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 2906919 PLC's (EC001420)
Feature Name Feature Value
Number of analogue inputs (EF001994) 1
Number of analogue outputs (EF001995) 0
Analogue inputs configurable (EF008518) Yes
Analogue outputs configurable (EF008519) No
Input, current (EF003204) No
Input, voltage (EF003205) No
Input, resistor (EF003206) No
Input, resistance thermometer (EF003207) Yes
Input, thermocouple (EF003208) No
Input signal, configurable (EF003209) Yes
Resolution of the analogue inputs (EF003575) 10 Bit
Output, current (EF003212) No
Output, voltage (EF003213) No
Output signal configurable (EF003214) No
Type of electric connection (EF003961) Other
Suitable for safety functions (EF001597) No
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Width (EF000008) 6.2 mm
Height (EF000040) 80 mm
Depth (EF000049) 94 mm

Product Datasheet