PHOENIX CONTACT SAC-2P- 0,5-PUR/M12FS PR DVS SAC-2P- 0,5-PUR/M12FS PR DVS 1574878 PHOENIX CONTACT Sensor/actuator cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-2P- 0,5-PUR/M12FS PR DVS 1574878 PHOENIX CONTACT Sensor/actuator cable

SAC-2P- 0,5-PUR/M12FS PR DVS

1574878

PHOENIX CONTACT

100 Pcs.

Sensor/actuator cable Sensor/actuator cable, 2-pole, PUR/PVC, greyish black RAL 7021, free cable end, to Straight connection female M12, coding: coded A, cable length: 0.5 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey1574878
Packing unit100 pc
Minimum order quantity100 pc
NoteMade to Order (non-returnable)
GTIN4046356447331
Weight per Piece (excluding packing)29.100 g
Custom tariff number85444290
Country of originPL (Poland)

Dimensions

Length of cable0.5 m

Ambient conditions

Degree of protectionIP65
IP67

General

Rated current at 40°C4 A
Rated voltage250 V AC
250 V DC
Number of positions2
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100
Torque0.4 Nm

Cable

Cable typePUR/PVC black
Cable abbreviationLiYY-11Y
UL AWM style20549
Conductor cross section0.34 mm²
AWG signal line22
Conductor structure signal line42x 0.10 mm
Core diameter including insulation1.5 mm ±0.05 mm
Thickness, insulation≥ 0.23 mm (Core insulation)
≥ 0.38 mm (Outer cable sheath)
Wire colorsbrown, blue
Overall twist2 wires, twisted
External sheath, colorblack-gray RAL 7021
External cable diameter D5.2 mm ±0.2 mm
Smallest bending radius, fixed installation52 mm
Smallest bending radius, movable installation52 mm
Number of bending cycles2000000
Bending radius52 mm
Traversing path5 m
Traversing rate3 m/s
Cable weight34 kg/km
Outer sheath, materialPUR
Material, inner sheathPVC
Material conductor insulationPVC
Conductor materialBare Cu litz wires
Insulation resistance≥ 100 MΩ*km (at 20 °C)
Conductor resistancemax. 58 Ω/km (at 20 °C)
Nominal voltage, cable≤ 300 V
Test voltage, cable≥ 3000 V
Flame resistancein accordance with DIN UL-Style 20549
Ambient temperature (operation)-25 °C ... 80 °C (cable, fixed installation)
-5 °C ... 80 °C (cable, flexible installation)

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values