PHOENIX CONTACT MINI MCR-EX-SD-16-50-LP-PT MINI MCR-EX-SD-16-50-LP-PT 1157870 PHOENIX CONTACT Ex i, Valve control block for operating intrinsically saf.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MINI MCR-EX-SD-16-50-LP-PT 1157870 PHOENIX CONTACT Ex i, Valve control block for operating intrinsically saf..

MINI MCR-EX-SD-16-50-LP-PT

1157870

PHOENIX CONTACT

1 Pcs.

Ex i, Valve control block for operating intrinsically safe solenoid valves in the area Ex. No-load voltage: 16 V, current limiting: 50 mA, Loop-powered, Safety Integrity Level (SIL, IEC61508): 3, Push-in connection Ex i-Valve control block for intrinsically safe solenoid valves in the Ex. zone No-load voltage: 16 V DC, current limiting: 50 mA, Standard configuration, Loop-powered, Safety Integrity Level (SIL, IEC 61508): 3, Push-in connection

Automation > Isolation amplifier
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Item Properties
Product TypeValve Control Block
Product FamilyMINI Analog Pro

Electrical Properties
Galvanic Separation
Surge CategoryII (≤ 5000 m)
Degree of pollution2 (≤ 5000 m)
Galvanic Separation Input/Output IEC/EN 61010-1
Standards/SpecificationsIEC/EN 61010-1
Sizing Insulation Voltage300 VEff
Test voltage2.5 kV AC (50 Hz, 60 sec)
IsolationDouble/reinforced insulation
Galvanic Separation Input/Output IEC/EN 60079-11
Standards/SpecificationsIEC/EN 60079-11
Sizing Insulation Voltage265 VEff
Galvanic Separation I/O I/O IEC/EN 60079-7
Standards/SpecificationsIEC/EN 60079-7
Sizing Insulation Voltage251 VEff
Feeding
Supply voltageLoop-powered, no external power required
Power Consumption< 1.4 W

Input data
Signal: Voltage
Number of Entries1
Input Signal Voltage19.2 V DC ... 30 V DC (24 V DC, -20% ... +25%)

Output Data
Signal: Voltage
Number of outputs1
Output voltage≥ 10.7 V DC (50 mA)
Output Resistance≥ 103 Ω (Inner Resistance Ri)
Current Limitation> 50 mA
Reaction Time< 50 ms
Open-circuit voltage> 16 V DC
Short circuit resistantYes

Connection data
AWG Conductor Section(Converted according to IEC)
Connection typePush-in connection
Length to be de-insulated10 mm
Rigid conductor section0.2 mm² ... 2.5 mm² (with toe cap)
0.14 mm² ... 2.5 mm² (without toe)
Flexible conductor section0.14 mm² ... 2.5 mm²
AWG Conductor Section24 ... 12 (flexible)

Ex Data
Ex Installation (EPL)Gc
Div. 2
Intrinsically safe circuits (EPL)Ga
Gives
Ma
Div. 1
Technical Safety Data
Internal inductance max. Lidespicable
Max. Internal Capacity Ci11 nF
Max. output voltage Uor19.2 V
Max. Output Current Ior185 mA
Max. output power Por888 mW
Maximum safety voltage Um253 V AC
125 V DC
IIA (Single Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor7 mH / 6.1 μF
IIB/IIIC (Single Electrical Circuit): External Inductance Max. Lor/ Max. external capacity Cor4 mH / 1.53 μF
IIC (Single Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor0.8 mH / 240 nF
I (single electrical circuit): External inductance max. Lor/ Max. external capacity Cor10 mH / 8.7 μF

Dimensions
Width6.2 mm
Height109.81 mm
Depth119.2 mm

Environmental and life-life conditions
Environmental conditions
Protection IndexIP20
Ambient Temperature (Service)-40 °C ... 70 °C
Ambient Temperature (Storage/Transport)-40 °C ... 85 °C
Permissible air humidity (service)5 % ... 95% (non-condensing)
Superior range of use (IEC/EN 61010-1)
Height Range> 2000 m ... 3000 m
Ambient Temperature (Service)-40 °C ... 63 °C
Sizing Insulation Voltage300 VEff(Input/Output)
IsolationDouble/reinforced insulation
Superior range of use (IEC/EN 61010-1)
Height Range> 3000 m ... 4000 m
Ambient Temperature (Service)-40 °C ... 56 °C
Sizing Insulation Voltage300 VEff(Input/Output)
IsolationDouble/reinforced insulation
Superior range of use (IEC/EN 61010-1)
Height Range> 4000 m ... 5000 m
Ambient Temperature (Service)-40 °C ... 49 °C
Sizing Insulation Voltage150 VEff(Input/Output)
IsolationDouble/reinforced insulation
Superior application range (IEC/EN 60079-11)
Height Range> 2000 m ... 3000 m
Ambient Temperature (Service)-40 °C ... 63 °C
Maximum safety voltage Um121 V AC
110 V DC
Sizing Insulation Voltage150 VEff(Input/Output)
Superior application range (IEC/EN 60079-11)
Height Range> 3000 m ... 4000 m
Ambient Temperature (Service)-40 °C ... 56 °C
Maximum safety voltage Um33 V AC/DC
Sizing Insulation Voltage60 VEff(Input/Output)
Superior application range (IEC/EN 60079-11)
Height Range> 4000 m ... 5000 m
Ambient Temperature (Service)-40 °C ... 49 °C
Maximum safety voltage Um33 V AC/DC
Sizing Insulation Voltage60 VEff(Input/Output)
Superior Operating Range (IEC/EN 60079-7)
Height Range> 2000 m ... 3000 m
Ambient Temperature (Service)-40 °C ... 63 °C
Sizing Insulation Voltage162 VEff(Input/Output)
Superior Operating Range (IEC/EN 60079-7)
Height Range> 3000 m ... 4000 m
Ambient Temperature (Service)-40 °C ... 56 °C
Sizing Insulation Voltage60 VEff(Input/Output)
Superior Operating Range (IEC/EN 60079-7)
Height Range> 4000 m ... 5000 m
Ambient Temperature (Service)-40 °C ... 49 °C
Sizing Insulation Voltage60 VEff(Input/Output)

Approvals
Ce
CertificateCE Compliance
ATEX
Marked II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 (1) G Ex ec [ia Ga] IIC T4 Gc
 I (M1) [Ex ia Ma] I
CertificateTÜV 21 ATEX 8651 X
IECEx
Marked[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex ec [ia Ga] IIC T4 Gc
[Ex ia Ma] I
CertificateIECEx TUR 21.0043 X
UKCA Ex (UKEX)
Marked II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 (1) G Ex ec [ia Ga] IIC T4 Gc
 I (M1) [Ex ia Ma] I
CertificateTÜV 21 UKEX 7021 X
CCC/China-Ex
Marked[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex ec [ia Ga] IIC T4 Gc
Certificate2023122310116238
UL, USA/Canada
MarkedUL 61010-2-201
Safety Integrity Level (SIL, IEC 61508)
Marked3

EMC data
Interference resistanceIEC/EN 61000-6-2
IEC/EN 61326-3-2
Electromagnetic compatibilityTesting according to the following standards and requirements: EN 61326-1 for use in the industrial field, NAMUR NE 21
Interference emissionIEC/EN 61000-6-4

Standards & Specifications
GB Standard
Standards/SpecificationsGB/T 3836.1
GB/T 3836.3
GB/T 3836.4

Product Datasheet