PHOENIX CONTACT MH-B10-12-MULTI-66-PA-LG MH-B10-12-MULTI-66-PA-LG 1299362 PHOENIX CONTACT Plates for cable passage, outer diameter of the cable: 5x 3.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MH-B10-12-MULTI-66-PA-LG 1299362 PHOENIX CONTACT Plates for cable passage, outer diameter of the cable: 5x 3..

MH-B10-12-MULTI-66-PA-LG

1299362

PHOENIX CONTACT

1 Pcs.

Plates for cable passage, outer diameter of the cable: 5x 3 mm ... 7mm, 4x 5mm... 10mm, 2x 7mm... 13mm, 1x 9mm... 16 mm, material: TPE-SEBS (outer material), color: light gray, length: 107 mm, width: 56 mm, height: 19 mm Cable feed-through plates Cable Feed-Through Plates, Cable Outer Diameter: 5x 3 mm ... 7mm, 4x 5mm... 10 mm, 2x 7 mm ... 13 mm, 1x 9 mm ... 16 mm, Material: TPE-SEBS (Outer Material), Color: Light Grey, Length: 107 mm, Width: 56 mm, Height: 19 mm

Automation > Gland plate for small distribution boards/switchgear cabinets
Industrial plug-in connectors/interfaces

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
Generalincl. fixing screws

Item Properties
Product TypeCable grommet frame

Connection data
Tightening torque1.8 Nm

Dimensions
Width56 mm
Height19 mm
Longitude107 mm

Material Data
MaterialTPE-SEBS
Flammability class according to UL 94V0

Cable/Line
Cable Outer Diameter ()5x 3 mm ... 7 mm
4x 5 mm ... 10 mm
2x 7 mm ... 13 mm
1x 9 mm ... 16 mm

Environmental and life-life conditions
Environmental conditions
Protection IndexIP66
Ambient Temperature (Service)-40 °C ... 90 °C

assembly
Installation instructionsSet screw M4, torque: 1.8 Nm, inner hexagon wrench width 5
The fixing screws included in the packaging must be used for assembly.

Assembly sequence:
1) Fix the Multigates with the attached set screws (note the pair)
2) Tap the hole in the membrane (with a screwdriver) or cut off the tip of the cone
3) Guide the wire (from the outside) through the hole. Remove the cable about 20 mm (to improve traction compensation)

ETIM for 1299362 Distribution boards (EC000211)
Feature Name Feature Value
Width (EF000008) 56 mm
Material (EF002169) Other
Pre-stamping (EF001039) No

Product Datasheet