PHOENIX CONTACT QUINT4-S-ORING/12-24DC/1X40 QUINT4-S-ORING/12-24DC/1X40 2907752 PHOENIX CONTACT Redundancy module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

QUINT4-S-ORING/12-24DC/1X40 2907752 PHOENIX CONTACT Redundancy module

QUINT4-S-ORING/12-24DC/1X40

2907752

PHOENIX CONTACT

1 Pcs.

Redundancy module Active single QUINT redundancy module for rail mounting, 12 to 24 VDC input, 12 to 24 VDC / 1 x 40 A output, including UTA 107/30 rail universal adapter mounted Active QUINT single redundancy module for DIN rail mounting, input: 12 V DC ... 24 V DC, output: 12 V DC ... 24 V DC / 1 x 40 A, incl. mounted UTA 107/30 universal DIN rail adapter

Automation > Surge protection module
Power Supplies (PS)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Input data
DC operation
Nominal input voltage range12 V DC ... 24 V DC
Input voltage range8 V DC ... 30 V DC
Typical national grid voltage12 V DC
24 V DC
Voltage type of supply voltageDC
Current consumption40 A
Static Boost (IStat.Boost)45 A
Dynamic Boost (IDyn.Boost)60 A (5 s)
Selective Fuse Breaking (ISFB)215 A (15 ms)
Reverse polarity protection< yes60 V
Nominal input current (IN)40 A (-40 °C ... 60 °C)
Input current IStatic45 A (40 °C)
Input current IDynamic60 A (5 s)
Input current ISFB215 A (15 ms)
Transient surge protectionVaristor
Voltage drop, input/output0.1 V

Output data
Efficiencytyp. 99.1 % (12 V DC)
typ. 99.3 % (24 V DC)
Nominal output voltageUIn- 0.1 V
Nominal output current (IN)40 A
Static Boost (IStat.Boost)45 A
Dynamic Boost (IDyn.Boost)60 A (5 s)
Selective Fuse Breaking (ISFB)215 A (15 ms)
Derating60 °C ... 70 °C (2.5 %/K)
Power loss nominal load max.6.5 W (IOUT= 40 A)
6 W (IOUT= 40 A)
Connection in seriesno
Signal: OK, 13/14
Output descriptionGroup contact
Maximum switching voltagemax. 30 V AC/DC
Maximum inrush current≤ 100 mA (short-circuit-proof)
Signal relay 13/14
Defaultopen
Additional textUIN
Signal relay 13/14
Defaultclosed
Additional textUIN> 8 V DC
Signal relay 13/14
Defaultopen
Additional textRedundancy module defective

Connection data
Input
Connection methodScrew connection
Conductor cross section, rigid min.0.5 mm²
Conductor cross section, rigid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.16 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.16 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.16 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4
Tightening torque, min1.2 Nm
Tightening torque max1.5 Nm
Output
Connection methodScrew connection
Conductor cross section, rigid min.0.5 mm²
Conductor cross section, rigid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.16 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.16 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.16 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4
Tightening torque, min1.2 Nm
Tightening torque max1.5 Nm
Signal
Connection methodPush-in connection
Conductor cross section, rigid min.0.2 mm²
Conductor cross section, rigid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.0.75 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Signaling
Types of signalingRelay contact, floating, current limited
Signal output: OK, 13/14
UIn< 8 V DCLED off, input voltage not present or short circuit at redundancy module output
UIn> 8 V DCLED lights up green, input voltage present
Redundancy modul faultyLED lights up red, redundancy module needs to be factory tested

Electrical properties
Insulation voltage input, output / housing500 V DC

Product properties
Product typeRedundancy module
Product familyQUINT S-ORING
MTBF (IEC 61709, SN 29500)> 25297000 h (25 °C)
> 15153000 h (40 °C)
> 7449000 h (60 °C)
LEDyes
Data management status
Article revision03
Insulation characteristics
Protection classIII
Degree of pollution2
Life expectancy (electrolytic capacitors)
Current40 A
Temperature40 °C
Time186000 h
Additional text12 V DC
Life expectancy (electrolytic capacitors)
Current40 A
Temperature40 °C
Time123000 h
Additional text24 V DC

Dimensions
Dimensional drawingcywqrgggqs.jpg
Width32 mm
Height130 mm
Depth125 mm
Installation dimensions
Installation distance right/left0 mm / 0 mm
Installation distance top/bottom40 mm / 20 mm
Alternative assembly
Width122 mm
Height130 mm
Depth35 mm

Mounting
Mounting typeDIN rail mounting
Assembly notealignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
Mounting positionhorizontal DIN rail NS 35, EN 60715

Material specifications
Flammability rating according to UL 94 (housing / terminal blocks)V0
Housing materialMetal
Housing materialAluminum / stainless steel
Type of housingAluminum (AlMg3)
Hood versionGalvanized sheet steel, free from chrome (VI)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 5000 m (> 2000 m, observe derating)
Climatic class3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Shock18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.

Standards and regulations
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Safety extra-low voltageIEC 60950-1 (SELV) and EN 60204-1 (PELV)
Standard - Safe isolationDIN VDE 0100-410

Approvals
Shipbuilding approvalDNV GL
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Conformity/Approvals
SIL in accordance with IEC 615080

EMC data
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Low Voltage DirectiveConformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emissionEN 61000-6-3
EN 61000-6-4
EMC requirements for noise immunityEN 61000-6-1
EN 61000-6-2
Conducted noise emissionEN 55016
EN 61000-6-3 (Class B)
Noise emissionAdditional basic standard EN 61000-6-5 (immunity in power station)
Noise emissionEN 55016
EN 61000-6-3 (Class B)
DNV GL conducted interferenceClass A
Additional textArea power distribution
DNV GL noise radiationClass B
Additional textBridge and deck area
Electrostatic discharge
Standards/regulationsEN 61000-4-2
Electrostatic discharge
Contact discharge8 kV (Test Level 4)
Discharge in air15 kV (Test Level 4)
CommentsCriterion B
Electromagnetic HF field
Standards/regulationsEN 61000-4-3
Electromagnetic HF field
Frequency range80 MHz ... 1 GHz
Test field strength20 V/m (Test Level 3)
Frequency range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
Frequency range1 GHz ... 6 GHz
Test field strength10 V/m (Test Level 3)
CommentsCriterion A
Fast transients (burst)
Standards/regulationsEN 61000-4-4
Fast transients (burst)
Input2 kV (Test Level 4 - asymmetrical)
Output2 kV (Test Level 4 - asymmetrical)
Signal2 kV (Test Level 4 - asymmetrical)
CommentsCriterion A
Surge voltage load (surge)
Standards/regulationsEN 61000-4-5
Surge voltage load (surge)
Input1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Output0.5 kV (Test Level 1 - symmetrical)
0.5 kV (Test Level 1 - asymmetrical)
Signal0.5 kV (Test Level 1 - asymmetrical)
CommentsCriterion B
Conducted interference
Standards/regulationsEN 61000-4-6
Conducted interference
I/O/Sasymmetrical
Frequency range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V (Test Level 3)
Power frequency magnetic field
Standards/regulationsEN 61000-4-8
Frequency16.67 Hz
50 Hz
60 Hz
Test field strength30 A/m
Additional text60 s
CommentsCriterion A
Criteria
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

ETIM for 2907752 Low-voltage industrial controls and switchgear (EC000683)
Feature Name Feature Value
Function (EF000030) Other
Voltage type (operating voltage) (EF005294) DC
Operating voltage DC (EF008208) 8 V