PHOENIX CONTACT MINI MCR-SL-PT100-UI-NC MINI MCR-SL-PT100-UI-NC 2864273 PHOENIX CONTACT Resistance thermometer measuring transducer View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MINI MCR-SL-PT100-UI-NC 2864273 PHOENIX CONTACT Resistance thermometer measuring transducer

MINI MCR-SL-PT100-UI-NC

2864273

PHOENIX CONTACT

1 Pcs.

Resistance thermometer measuring transducer MCR temperature converter for Pt 100 temperature sensors, configurable via DIP switch, with screw connection, without presetting

Automation > Temperature transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2864273
Packing unit1 pc
Catalog pagePage 105 (C-7-2015)
GTIN4017918956561
Weight per Piece (excluding packing)99.200 g
Custom tariff number85437090
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width6.2 mm
Height93.1 mm
Depth102.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Input data

Configurable/programmableYes
Sensor types (RTD) that can be usedPt 100 (IEC 60751/EN 60751)
Sensor input current1 mA (constant)
Connection technology2, 3, 4-wire

Output data

Number of outputs1
Configurable/programmableYes, unconfigured
Voltage output signal0 V ... 10 V
10 V ... 0 V
0 V ... 5 V
1 V ... 5 V
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA
Max. output voltageapprox. 12.5 V
Max. output current23 mA
Short-circuit currentapprox. 10 mA
Load/output load voltage output≥ 10 kΩ
Load/output load current output< 500 Ω (at 20 mA)
Ripple< 20 mVPP(at 10 kΩ)
< 20 mVPP(at 500 Ω)

Power supply

Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Max. current consumption< 21 mA (at 24 V DC)
Power consumption< 500 mW

Connection data

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.12
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length12 mm
Screw threadM3

General

No. of channels1
Transmission error in the set measuring range((100 K / set measurement range [K]) + 0.1)%
Transmission error in the full measuring range≤ 0,2 %
Maximum temperature coefficient< 0.02 %/K
Protective circuitTransient protection
Electrical isolationBasic insulation according to EN 61010
Overvoltage categoryII
Degree of pollution2
Rated insulation voltage50 V AC/DC
Test voltage, input/output/supply1.5 kV (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Colorgreen
Housing materialPBT
Mounting positionany
Assembly instructionsThe T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA/CanadaUL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GLGL EMC 2 D
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value10 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value10 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value10 %

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
EN 61000-4-4
EN 61000-4-5
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Electrical isolationBasic insulation according to EN 61010
ConformanceCE-compliant
ATEX II 3 G Ex nA IIC T4 Gc X
UL, USA/CanadaUL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5
GLGL EMC 2 D
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 2

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 2864273 Sensors (EC002919)
Feature Name Feature Value
Measuring range (EF001836) -150 °C
Analogue output 0 mA ... 20 mA (EF006808) No
Analogue output 4 mA ... 20 mA (EF006810) No
Analogue output 0 V ... 2 V (EF009886) No
Analogue output 0 V ... 5 V (EF009887) Yes
Analogue output 0 V ... 10 V (EF006807) Yes
Analogue output 2 V ... 10 V (EF009888) No
With switching output (EF005225) No
Modular version (EF001126) Yes
Integrated configuration function (EF003064) Yes
EMC-version (EF001062) Yes
Ambient temperature (EF002386) 65 °C
Weight (EF000167) 0.0977 kg

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.