View larger
VAL-MS 400/3+0/VF-FM
2910476
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2910476 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| GTIN | 4055626459172 |
| Weight per Piece (excluding packing) | 393.500 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
| Degree of protection | IP20 (only when all terminal points are used) |
|---|---|
| Ambient temperature (operation) | -40 °C ... 80 °C |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 5000 m (amsl (above mean sea level)) |
| Permissible humidity (operation) | 5 % ... 95 % |
| Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Vibration (operation) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
| IEC test classification | II |
|---|---|
| T2 | |
| EN type | T2 |
| Mode of protection | L-PE |
| L-L | |
| Mounting type | DIN rail: 35 mm |
| Color | jet black RAL 9005 |
| Housing material | PA 6.6 |
| PBT | |
| Degree of pollution | 2 |
| Flammability rating according to UL 94 | V-0 |
| Type | DIN rail module, two-section, divisible |
| Number of positions | 4 |
| Surge protection fault message | Optical, remote indicator contact |
| Note | Burst test up to 4 kV passed according to DIN EN 61000-4-4. |
|---|---|
| Insulates against repetitive pulses up to 1.5 kV. | |
| Only usable in IT Systems between L-PE, if the exposed-conductive-parts (bodies) of the equipment of the low-voltage installation is connected to the earthing arrangement of the transformer substation (interconnected earthing arrangement of the HV-transformer substation with the bodies of the LV-installation. RE= RAaccordance to IEC 60364-4-442 / VDE 0100-442 Fig. 44D / Example a). | |
| At altitudes > 2000 m (amsl), a lateral distance of 2 mm must be maintained between live and grounded parts. |
| Nominal voltage UN | 400 V AC (IT) |
|---|---|
| Nominal frequency fN | 50 Hz (60 Hz) |
| Maximum continuous voltage UC | 440 V AC |
| Rated load current IL | 80 A |
| Residual current IPE | ≤ 5 µA |
| Standby power consumption PC | ≤ 600 mVA |
| Nominal discharge current In(8/20) µs | 20 kA |
| Maximum discharge current Imax(8/20) µs | 40 kA |
| Short-circuit current rating ISCCR | 25 kA |
| Voltage protection level Up(L-L) | ≤ 4 kV |
| Voltage protection level Up(L-PE) | ≤ 3.5 kV |
| Residual voltage Ures(L-L) | ≤ 4 kV (at In) |
| Residual voltage Ures(L-PE) | ≤ 2.3 kV (at In) |
| Response time tA(L-L) | ≤ 25 ns |
| Response time tA(L-PE) | ≤ 100 ns |
| Max. backup fuse with V-type through wiring | 80 A (gG) |
| Max. backup fuse with branch wiring | 100 A (gG) |
| Switching function | PDT contact |
|---|---|
| Operating voltage | 5 V AC ... 250 V AC (Altitude ≤ 2000 m amsl) |
| 5 V AC ... 150 V AC (Altitude > 2000 m amsl) | |
| 30 V DC | |
| Operating current | 5 mA AC ... 750 mA AC |
| 1 A DC | |
| Connection method | Plug-in/screw connection via COMBICON |
| Screw thread | M2 |
| Tightening torque | 0.25 Nm |
| Stripping length | 7 mm |
| Conductor cross section flexible | 0.14 mm² ... 1.5 mm² |
| Conductor cross section solid | 0.14 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 |
| Connection method | Screw connection |
|---|---|
| Screw thread | M5 |
| Tightening torque | 3 Nm (1,5 mm² ... 16 mm²) |
| 4.5 Nm (25 mm² ... 35 mm²) | |
| Stripping length | 16 mm |
| Conductor cross section flexible | 1.5 mm² ... 25 mm² |
| Conductor cross section solid | 1.5 mm² ... 35 mm² |
| Conductor cross section AWG | 15 ... 2 |
| Connection method | Fork-type cable lug |
| Conductor cross section flexible | 1.5 mm² ... 16 mm² |
| Feature Name | Feature Value |
|---|---|
| System configuration DC (EF009926) | No |
| System configuration IT (EF009927) | Yes |
| System configuration TN (EF009928) | No |
| System configuration TN-C (EF009929) | No |
| System configuration TN-C-S (EF009933) | No |
| System configuration TN-S (EF009930) | No |
| System configuration TT (EF009931) | No |
| System configuration other (EF009932) | No |
| Nominal discharge surge current (8/20) (EF004214) | 20 kA |
| Max. discharge surge current (8/20) (EF012274) | 40 kA |
| Max. continuous voltage AC (EF004198) | 440 V |
| Voltage protection level (EF003525) | 3.5 kV |
| Max. overcurrent protection device, parallel connection (fuse) (EF015962) | 100 A |
| Max. overcurrent protection device, series connection (fuse) (EF015963) | 80 A |
| Short-circuit breaking capacity (Isccr) (EF012627) | 25 kA |
| Integrated backup fuse (EF008797) | Yes |
| Leakage-current free (EF016002) | No |
| Mounting method (EF000003) | DIN rail (top hat rail) 35 mm |
| Construction size (EF002566) | Other |
| Max. conductor cross section solid (solid, stranded) (EF008827) | 1.5 mm² |
| Max. conductor cross section flexible (fine-strand) (EF008828) | 25 mm² |
| With remote signalling contact (EF000422) | Yes |
| Signalling at the device (EF004241) | Optic |
| Category type 2 (EF004230) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |