| Product Type | Conductive Plate Connector |
| Product range | MC 1.5/.. -STF |
| Product Line | COMBICON Connectors S |
| Number of poles | 2 |
| Steps | 3.81 mm |
| Number of connections | 2 |
| Number of rows | 1 |
| Number of potentials | 2 |
| Data Management Status | |
| Revision of the article | 03 |
| Rated Current IN | 8 A |
| Rated voltage UN | 160 V |
| Contact resistance | 1.3 mΩ |
| Reference voltage (III/3) | 160 V |
| Rated Shock Resistance Voltage (III/3) | 2.5 kV |
| Rated Voltage (III/2) | 160 V |
| Rated Shock Withstand Voltage (III/2) | 2.5 kV |
| Reference voltage (II/2) | 320 V |
| Rated Shock Withstand Voltage (II/2) | 2.5 kV |
| Connection technology | |
| Type | Standard |
| Connector System | COMBICON MC 1,5 |
| Nominal cross-section | 1.5 mm² |
| Contact Type | Female connector |
| Locking | |
| Lock Mode | Screw lock |
| Mounting Flange | Screw flange |
| Tightening torque | 0.3 Nm |
| Conductor connection | |
| Connection type | Screwed connection with ring |
| Conductor/PCB Plugging Direction | 0 ° |
| Rigid conductor cross-section | 0.14 mm² ... 1.5 mm² |
| Soft conductor section | 0.14 mm² ... 1.5 mm² |
| Conductive section. AWG | 28 ... 16 |
| Soft conductor section with end cap, without plastic bushing | 0.25 mm² ... 1.5 mm² |
| Soft conductor section with plastic end cap and socket | 0.25 mm² ... 0.75 mm² |
| 2 rigid conductors of the same cross-section | 0.08 mm² ... 0.5 mm² |
| 2 flexible conductors of the same cross-section | 0.08 mm² ... 0.75 mm² |
| 2 conductors of the same cross-section, flexible with plastic sleeveless end cap | 0.25 mm² ... 0.34 mm² |
| 2 flexible conductors of the same cross-section with TWIN bit and plastic socket | 0.5 mm² ... 0.5 mm² |
| Template a x b / diameter | 2.4 mm x 1.5 mm / 1.6 mm |
| Stripping length | 7 mm |
| Screw head drive shape | Longitudinal Slot (L) |
| Tightening torque | 0.22 Nm ... 0.25 Nm |
| Data for Bits Without Insulating Collar | |
| Recommended crimping tool | 1212034 CRIMPFOX 6 |
| Data for Bits with Insulating Collar | |
| Recommended crimping tool | 1212034 CRIMPFOX 6 |
| Material indication - contact | |
| Note | WEEE/RoHS compliant, trichite-free according to IEC 60068-2-82/JEDEC JESD 201 |
| Contact material | Cu Alloy |
| Surface quality | Tinned by hot dipping |
| Metal surface connection point (top layer) | Tin (4 - 8 μm Sn) |
| Metal surface, contact area (top layer) | Tin (4 - 8 μm Sn) |
| Material indication - housing | |
| Colors (Cases) | Green (6021) |
| Insulating material | PA |
| Insulation Group | I |
| CRI according to IEC 60112 | 600 |
| Flammability class according to UL 94 | V0 |
| GWFI glow wire flammability class according to EN 60695-2-12 | 850 |
| GWIT glow wire ignition temperature according to EN 60695-2-13 | 775 |
| Ball pressure test temperature according to EN 60695-10-2 | 125 °C |
| Dimensioned drawing | |
| Steps | 3.81 mm |
| Width [w] | 18.01 mm |
| Height [h] | 11.1 mm |
| Length [l] | 16.1 mm |
| Flange | |
| Tightening torque | 0.3 Nm |
| Investigation of damage and loosening of conductors | |
| Control Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Result | Successful test |
| Traction Control | |
| Control Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Conductor cross-section/conductor type/tractive force, nominal/actual | 0.14 mm² / rigid / > 7 N |
| 0.14 mm² / soft / > 7 N | |
| 1.5 mm² / rigid / > 40 N | |
| 1.5 mm² / soft / > 40 N | |
| Plug-in and Shrink Forces | |
| Control Specification | DIN EN 60512-13-2:2006-11 |
| Result | Successful test |
| Number of cycles | 25 |
| Approx. mating force per pole | 6 N |
| Removal force per pole approx. | 4 N |
| Torque Control | |
| Control Specification | DIN EN 60999-1 (VDE 0609-1):2000-12 |
| Resistance of inscriptions | |
| Control Specification | DIN EN 60068-2-70:1996-07 |
| Result | Successful test |
| Polarization and keying | |
| Control Specification | DIN EN 60512-13-5:2006-11 |
| Result | Successful test |
| Visual inspection | |
| Control Specification | DIN EN 60512-1-1:2003-01 |
| Result | Successful test |
| Dimension control | |
| Control Specification | DIN EN 60512-1-2:2003-01 |
| Result | Successful test |
| Vibration Resistance Test | |
| Control Specification | DIN EN 60068-2-6 (VDE 0468-2-6):2008-10 |
| Frequency | 10 - 150 - 10 Hz |
| Scan Speed | 1 octave/min |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Acceleration | 5g (60.1 Hz ... 150 Hz) |
| Inspection time per axis | 2.5 hrs |
| Sense of control | X, Y, and Z Axes |
| Lifetime test | |
| Control Specification | DIN EN 60512-9-1 (VDE 0687-512-9-1):2010-12 |
| Shock Resistance Voltage at Sea Level | 2.95 kV |
| Passage resistance R1 | 1.3 mΩ |
| Passage resistance R2 | 1.5 mΩ |
| Number of mating cycles | 25 |
| Insulation resistance of neighboring poles | > 5 MΩ |
| Climate control | |
| Control Specification | DIN EN ISO 6988:1997-03 |
| Corrosion susceptibility | 0.2 dm3SO2about 300 dm3/40 °C/1 cycle |
| Heat sensitivity | 100 °C/168 h |
| Alternating current withstand voltage | 1.39 kV |
| Shocks | |
| Control Specification | DIN EN 60068-2-27 (VDE 0468-2-27):2010-02 |
| Shock form | Semi-sinusoidal |
| Acceleration | 30g |
| Duration of shocks | 18 ms |
| Sense of control | X, Y and Z axes (pos. and neg.) |
| Environmental conditions | |
| Ambient Temperature (Operating) | -40 °C ... 100 °C (depending on the derating curve) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Thermal Testing Test Group C | |
| Control Specification | DIN EN 60512-5-1:2003-01 |
| Number of poles tested | 20 |
| Insulation resistance | |
| Control Specification | DIN EN 60512-3-1:2003-01 |
| Insulation resistance of neighboring poles | > 5 MΩ |
| Air Distances and Trailing Lines | |
| Control Specification | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Insulation Group | I |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | SIC 600 |
| Rated Insulation Voltage (III/3) | 160 V |
| Rated Shock Resistance Voltage (III/3) | 2.5 kV |
| minimum value of distance in air - non-homogeneous field (III/3) | 1.5 mm |
| minimum creepage value (III/3) | 2 mm |
| Note on the connection section | With 1.5 mm² connected conductor (rigid). |
| Rated Insulation Voltage (III/2) | 160 V |
| Rated Shock Voltage (III/2) | 2.5 kV |
| minimum value of distance in air - non-homogeneous field (III/2) | 1.5 mm |
| minimum creepage value (III/2) | 1.5 mm |
| Rated Insulation Voltage (II/2) | 320 V |
| Rated Shock Withstand Voltage (II/2) | 2.5 kV |
| minimum value of distance in air - non-homogeneous field (II/2) | 1.5 mm |
| minimum creepage value (II/2) | 1.6 mm |
| Type of packaging | packed in a carton |
| Feature Name | Feature Value |
|---|---|
| Type of connection (EF000064) | Other |
| Contact type (EF001587) | Bus |
| Number of poles (EF001391) | 2 |
| Number of plug-in contact rows (EF006935) | 1 |
| Modular spacing contacts (EF007326) | 3.81 mm |
| Modular spacing connections (EF006827) | 3.81 mm |
| Angle contact/conductor connection (EF007546) | Other |
| Rated current In (EF008250) | 8 A |
| Rated voltage (EF000228) | 160 V |
| Rated surge voltage (EF002993) | 2.5 kV |
| Over voltage category (EF006785) | III |
| Pollution degree (EF006786) | 2 |
| Connectable conductor cross section fine-strand without cable end sleeve (EF007341) | 0.14 mm² |
| Connectable conductor cross section fine-strand with cable end sleeve (EF007339) | 0.25 mm² |
| Connectable conductor cross section solid-core (EF007337) | 0.14 mm² |
| Type of electric connection (EF003961) | Screw connection |
| Connectable cable type (EF006816) | Tubular cable |
| Material of contact surface (EF004020) | Tin |
| Material contact (EF007544) | Copper |
| Material insulation body (EF007543) | Polyamide (PA) |
| Housing material (EF001596) | Other |
| Housing colour (EF000136) | Green |
| Inflammability class of insulation material according to UL94 (EF002521) | V0 |
| Operating temperature (EF002393) | -40 °C |