PHOENIX CONTACT MACX MCR-TS-I-OLP-SP MACX MCR-TS-I-OLP-SP 2908664 PHOENIX CONTACT Temperature measuring transducer View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MACX MCR-TS-I-OLP-SP 2908664 PHOENIX CONTACT Temperature measuring transducer

MACX MCR-TS-I-OLP-SP

2908664

PHOENIX CONTACT

1 Pcs.

Temperature measuring transducer Output loop-fed temperature converter to transmit up to 2 sensor signals from RTD and CT sensors, as well as resistance and voltage transmitters via 4 mA... 20 mA. HART, Standard Configuration, Safety Integrity Level (SIL, IEC61508): 2, Systematic Capability: 3, Push-in Connection

Automation > Temperature transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2908664
Packing unit1 pc
Catalog pagePage 194 (C-5-2017)
GTIN4055626355443
Weight per Piece (excluding packing)169.000 g
Custom tariff number85437090
Country of originDE (Germany)

Dimensions

Width12.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
-40 °C ... 70 °C (SIL active)
Ambient temperature (storage/transport)-40 °C ... 100 °C
Maximum altitude≤ 4000 m (Above sea level)

Input data

Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)A, B, C, D, E, J, K, L, N, R, S, T, U
Linear resistance measuring range10 Ω ... 2000 Ω (Minimum measuring span: 10 Ω)
Temperature measuring range-250 °C ... 2500 °C (Range depending on the sensor type)
-200 °C ... 850 °C (Pt 100)

Output data

Configurable/programmableno
Current output signal4 mA ... 20 mA
20 mA ... 4 mA
Max. output current23 mA

Power supply

Supply voltage range12 V ... 42 V
12 V ... 32 V (SIL active)

Connection data

Connection methodPush-in connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Stripping length8 mm

General

Overvoltage categoryII
Degree of pollution2
ConformanceCE-compliant
ATEX II 3G Ex nA IIC T6...T4 Gc
UL, USA/CanadaUL 61010 Recognized
FM approvalNI, Class I, Div. 2, Groups A, B, C, D
CSANI / Class I / Div. 2 / ABCD T6/T5/T4

Standards and Regulations

ConformanceCE-compliant
ATEX II 3G Ex nA IIC T6...T4 Gc
UL, USA/CanadaUL 61010 Recognized
FM approvalNI, Class I, Div. 2, Groups A, B, C, D
CSANI / Class I / Div. 2 / ABCD T6/T5/T4

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 2908664 Sensors (EC002919)
Feature Name Feature Value
Measuring range (EF001836) -250 °C
Analogue output 0 mA ... 20 mA (EF006808) No
Analogue output 4 mA ... 20 mA (EF006810) Yes
Analogue output 0 V ... 2 V (EF009886) No
Analogue output 0 V ... 5 V (EF009887) No
Analogue output 0 V ... 10 V (EF006807) No
Analogue output 2 V ... 10 V (EF009888) No
With switching output (EF005225) No
Modular version (EF001126) Yes
Integrated configuration function (EF003064) No
Ambient temperature (EF002386) 85 °C
Weight (EF000167) 0.169 kg

Product Datasheet