PHOENIX CONTACT MACX MCR-TC-I MACX MCR-TC-I 1050228 PHOENIX CONTACT Temperature transducer: converts signals from thermocouples and mV sou.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

MACX MCR-TC-I 1050228 PHOENIX CONTACT Temperature transducer: converts signals from thermocouples and mV sou..

MACX MCR-TC-I

1050228

PHOENIX CONTACT

1 Pcs.

Temperature transducer: converts signals from thermocouples and mV sources into 0/4…20 mA signals. Freely programmable, 3-way electrical isolation, screw connection, SIL. Temperature converter: transforms signals from thermocouples and mV sources into 0/4-20 mA signals. Free programming, 3-way galvanic separation, screw connection, SIL.

Automation > Temperature transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
Utilization restriction
EMC noteEMC: class A product, see manufacturer's declaration in the download area

Product properties
Product typeTemperature transmitter
Product familyMACX Analog
ApplicationTemperature
No. of channels1
TypeSignal conditioners with SIL functional safety
ConfigurationSoftware
Data management status
Article revision06
Insulation characteristics: GB Standard
Overvoltage categoryII
Pollution degree2

Electrical properties
Electrical isolation3-way isolation
Cold point error, max.± 2 K
Step response (0–99%)1 s
≤ 1.7 s
Temperature coefficient, typical0.01 %/K
Transmission error, typical0.1 % (For full identification of transmission errors, see the data sheet)
Electrical isolation Input/output/power supply
Rated insulation voltage300 Vrms
Test voltage2.5 kV AC (50 Hz, 60 s)
InsulationSafe isolation in accordance with IEC/EN 61010-1
Electrical isolation Input/output
Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)
Electrical isolation Input/power supply
Electrical isolation375 V (Peak value in accordance with IEC/EN 60079-11)
Supply
Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC, -20 % ... +25 %)
Max. current consumption< 40 mA (24 V DC)
Power dissipation≤ 0.76 W
Power consumption≤ 1 W

Input data
Signal
Number of inputs1
Input signalTemperature
Voltage
Measurement
Sensor types that can be used (TC)B, E, J, K, N, R, S, T, L, U, C, D, A-1, A-2, A-3, M, Lr
Temperature measuring range-250 °C ... 2500 °C (Range depending on the sensor type)
Sensor type:500 °C ... 1820 °C
-230 °C ... 1000 °C
-210 °C ... 1200 °C
-250 °C ... 1372 °C
-200 °C ... 1300 °C
-50 °C ... 1768 °C
-50 °C ... 1768 °C
-200 °C ... 400 °C
-200 °C ... 900 °C
-200 °C ... 600 °C
0 °C ... 2315 °C
0 °C ... 2315 °C
0 °C ... 2500 °C
0 °C ... 1800 °C
0 °C ... 1800 °C
-200 °C ... 100 °C
-200 °C ... 800 °C
Linear mV signal range-1000 mV ... 1000 mV
Temperature measuring rangeMin. 50 K with thermocouple, 10% of the nominal span of the respective range with mV sources

Output data
Signal: Current
Number of outputs1
Configurable/programmableYes
Current output signal0 mA ... 20 mA
4 mA ... 20 mA (SIL)
Load/output load current output≤ 600 Ω
Output ripple (current)< 15 µAPP
< 10 µArms
Behavior in the event of a sensor errorAs per NE 43 or can be freely defined

Connection data
Connection methodScrew connection
Stripping length7 mm
Screw threadM3
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Tightening torque0.5 Nm ... 0.6 Nm
Test socket
Max. diameter2 mm

Ex data
Ex installation (EPL)Gc
Div. 2

Signaling
Status displayGreen LED (supply voltage)
Red LED, flashing 2.4 Hz (cable error, sensor error on input or output, ERR)
Red LED, flashing 1.2 Hz (service operation, ERR)
Red LED, permanently on (module error, ERR)

Dimensions
Dimensional drawingleiqvoyqna.jpg
Width12.5 mm
Height112.5 mm
Depth113.7 mm
Depth NS 35/7,5114.5 mm (Snapped onto DIN rail NS 35/7,5 in accordance with EN 60715)

Material specifications
Colorgray (RAL 7042)
Flammability rating according to UL 94V0 (Housing)
Housing materialPA 6.6-FR

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 70 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Altitude range (≤ 2000 m)
Altitude≤ 2000 m (The technical data refers to altitudes ≤2000 m above mean sea level. For altitudes >2000 m above mean sea level, refer to the data sheet.)
Ambient temperature (operation)-40 °C ... 70 °C
Test voltage2.5 kV
Rated insulation voltage300 Vrms
Altitude range (≤ 3000 m)
Height range> 2000 m ... 3000 m
Ambient temperature (operation)-40 °C ... 60 °C
Test voltage2.25 kV
Rated insulation voltage150 Vrms
Altitude range (≤ 4000 m)
Height range> 3000 m ... 4000 m
Ambient temperature (operation)-40 °C ... 55 °C
Test voltage2 kV
Rated insulation voltage150 Vrms
Altitude range (≤ 5000 m)
Height range> 4000 m ... 5000 m
Ambient temperature (operation)-40 °C ... 49 °C
Test voltage1.75 kV
Rated insulation voltage150 Vrms

Approvals
CE
CertificateCE-compliant
Noteand EN 61326
ATEX
Identification II 3 G Ex ec ic IIC T4 Gc
CertificatePxCIF19ATEX1050192X
UKCA Ex (UKEX)
Identification II 3 G Ex ec ic IIC T4 Gc
CertificatePxCIF21UKEX1050192X
IECEx
IdentificationEx ec ic IIC T4 Gc
CertificateIECEx IBE 19.0001 X
CCC / China-Ex
IdentificationEx nA ic IIC T4 Gc
CertificateNEPSI GYJ20.1305X
UL, USA/Canada
IdentificationUL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
Shipbuilding approval
CertificateDNV GL TAA00000AG
Safety Integrity Level (SIL, IEC 61508)
Identification2
CertificateSEBS-A.150520/17, V2.0
EAC Ex
Identification 2Ex ec ic IIC T4 Gc
CertificateBY/112 02.01 TP012 103.01 00082
DNV GL data
TemperatureB
HumidityB
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data
Electromagnetic compatibilityConformance with EMC directive
Noise immunityEN 61000-6-2
NoteWhen being exposed to interference, there may be minimal deviations.
Noise emissionEN 61000-6-4
Electromagnetic HF field
DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value1 %
Fast transients (burst)
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value1 %
Conducted interference
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value1 %

Standards and regulations
Electrical isolation3-way isolation
GB Standard
Standards/regulationsGB 3836.1
GB 3836.4
GB 3836.8

Mounting
Mounting typeDIN rail mounting

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.