MACX MCR-EX-AP-2T-2I-SP 1290849 PHOENIX CONTACT Ex i-Temperature converters, input signals Ex i of resistanc..

MACX MCR-EX-AP-2T-2I-SP

1290849

PHOENIX CONTACT

1 Pcs.

Ex i-Temperature converters, input signals Ex i of resistance thermometers in 2, 3 or 4 conductor technology, thermocouples and mV sources are converted to 0 mA / 4 mA non-Ex i signals... 20 mA active. Standard Configuration, 5-Way Spacing, Push-in Connection Ex i, Temperature converters, Ex i input signals of resistance thermometers in 2, 3 or 4 conductor technology, thermocouples and mV sources are converted to 0 mA / 4 mA non-Ex i signals... 20 mA active. 2-Channel, Universal, Free Programming, 5-Way Separation, Push-in Connection

Automation > Temperature transformer
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
GeneralAccuracy, typical data in % of the basic measurement interval with UN, 23 °C
GeneralThe installation conditions influence the ambient temperature.
Please note the operating instructions.
GeneralOutput behavior = 2.4 mA (can be set to 0 mA ... 23 mA or "hold the last value")
GeneralSensor adjustment via software or DIP switch
General2-conductor adjustment via DIP ADJ switch
GeneralInput sizes are adjusted via ISpac Wizard parameterization software or DIP switch.

Item Properties
Product TypeTemperature Converter
Product FamilyMACX Analog
Number of channels2
ConfigurationSoftware

Electrical Properties
Number of channels2
Galvanic Separation5-way spacing
Typical Temperature Coefficient≤ 0.1% (10K)
Polarity reversal protectionYes
Galvanic Separation Input/Output IEC/EN 60079-11
Standards/SpecificationsIEC/EN 60079-11
Sizing Insulation Voltage375 VPP
Galvanic Separation Input/Power IEC/EN 60079-11
Standards/SpecificationsIEC/EN 60079-11
Sizing Insulation Voltage375 VPP
Galvanic Separation IEC/EN 60079-11 Error Signaling Input/Output
Standards/SpecificationsIEC/EN 60079-11
Sizing Insulation Voltage375 VPP
Galvanic Separation Input / Configuration Interface IEC/EN 60079-11
Standards/SpecificationsIEC/EN 60079-11
Sizing Insulation Voltage375 VPP
Galvanic Separation Output 1 / Output 2
Test voltage350 V (50 Hz, 60 sec)
Galvanic Separation Output/Feed
Test voltage350 V (50 Hz, 60 sec)
Galvanic Separation Output/Configuration Interface
Test voltage350 V (50 Hz, 60 sec)
Galvanic Separation Fault Signaling Output/Power/Output
Test voltage350 V (50 Hz, 60 sec)
Feeding
Nominal Supply Voltage24 V DC
Supply voltage18 V ... 31.2 V
Dissipated Power≤ 1.9 W
Power Consumption≤ 1.9 W

Input data
Measurement
Ticket DescriptionHeat resistance
Usable Sensor Types (RTDs)Pt 100, Pt 250, Pt 500, Pt 1000, Pt 2000, Ni 100, Ni 500, Ni 1000, M50, M53, M100
Temperature Measuring Range-200 °C ... 1100 °C (Range depending on sensor type)
Connection technology2, 3, 4 conductors
Total permissible line resistance max.50 Ω (per wire, 2-conductor circuit)
100 Ω (per wire, 3, 4 conductor circuit)
Measuring Range, Temperature≥ 51 K (Range depending on sensor type)
Measurement
Ticket DescriptionThermocouple
Usable Sensor Types (CTs)B, E, J, K, N, R, S, T, L, U, XK
Temperature Measuring Range-200 °C ... 1800 °C (Range depending on sensor type)
Total permissible line resistance max.≤ 1000 Ω (per driver)
Measuring Range, Temperature≥ 36 K (Range depending on sensor type)
Measurement
Ticket DescriptionPotentiometer
Connection technology3 conductors
Linear Resistance Margin50 Ω ... 500 Ω
0.5 kΩ ... 5 kΩ
1 kΩ ... 10 kΩ
10 kΩ ... 100 kΩ (with parallel 10 kΩ shunt, no cable break monitoring)

Output Data
Notify: Error Signaling Output
Maximum Switching Voltage30 V
Maximum switching current100 mA
Signal: Current
Current Output Signal0 mA ... 20 mA (configurable)
4 mA ... 20 mA (configurable)
0 mA ... 21 mA (Operating Range)
Load0 Ω ... 600 Ω (per channel)

Connection data
AWG Conductor Section(Converted according to IEC)
Connection typePush-in connection
Length to be de-insulated8 mm
Rigid conductor section0.2 mm² ... 1.5 mm²
Flexible conductor section0.2 mm² ... 1.5 mm²
AWG Conductor Section24 ... 16

Ex Data
Ex Installation (EPL)Gc
Intrinsically safe circuits (EPL)Ga
Gives
Ma
Technical Safety Data
Internal inductance max. Lidespicable
Max. Internal Capacity Cidespicable
Max. output voltage Uor6.5 V
Max. Output Current Ior19.7 mA
Max. output power Por32 mW (linear characteristic curve)
Maximum safety voltage Um253 V AC
IIA (Single Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor700 mH / 1000 μF
IIB (Single Electrical Circuit): External Inductance Max. Lor/ Max. external capacity Cor330 mH / 570 μF
IIC (Single Electrical Circuit): External inductance max. Lor/ Max. external capacity Cor90 mH / 25 μF
I (single electrical circuit): External inductance max. Lor/ Max. external capacity Cor700 mH / 1000 μF

Signage
Status IndicationGreen LED (supply voltage)
Red LED (Line Error)

Dimensions
Dimension Schemekrbhdfxwui.jpg
Width17.5 mm
Height107.8 mm
Depth113.7 mm
Depth NS 35/7.5114.5 mm (fitted on DIN rail NS 35/7.5 according to EN 60715)

Material Data
Flammability class according to UL 94V0
Shell materialPolyamide (PA 6.6)

Environmental and life-life conditions
Environmental conditions
Protection IndexIP20 (Terminals)
IP30 (Housing)
Ambient Temperature (Service)-20 °C ... 70 °C (Individual Equipment: Discretionary Mounting Position)
-20 °C ... 40 °C (Installation in groups: vertical DIN rail without air circulation)
-20 °C ... 60 °C (Bracket mounting: vertical DIN rail with air circulation)
-20 °C ... 50 °C (Mounting in groups: horizontal DIN rail without air circulation)
-20 °C ... 70 °C (Bracket mounting: horizontal DIN rail with air circulation)
Ambient Temperature (Storage/Transport)-40 °C ... 80 °C
Altitude≤ 2000 m
Permissible air humidity (service)≤ 95% (non-condensing)

Approvals
ATEX
Marked II (1) G [Ex ia Ga] IIC
 II (1) D [Ex ia Da] IIIC
 II 3 (1) G Ex nA nC [ia Ga] IIC T4 Gc
 I (M1) [Ex ia Ma] I
IECEx
Marked[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex nA nC [ia Ga] IIC T4 Gc
[Ex ia Ma] I

EMC data
Electromagnetic compatibilityTesting according to the following standards and requirements: EN 61326-1 for use in the industrial field, NAMUR NE 21

Standards & Specifications
Galvanic Separation5-way spacing

assembly
Type of mountingNS 35/15, NS 35/7.5
Position for mountingvertical, horizontal

ETIM for 1290849 Sensors (EC002919)
Feature Name Feature Value
Measuring range (EF001836) -200 °C
Analogue output 0 V ... 2 V (EF009886) No
Analogue output 0 V ... 5 V (EF009887) No
Analogue output 0 V ... 10 V (EF006807) No
Analogue output 2 V ... 10 V (EF009888) No
With switching output (EF005225) No
Ambient temperature (EF002386) 70 °C
Weight (EF000167) 0.1331 kg

Product Datasheet