PHOENIX CONTACT K-8E-M23M8/10,0-H01/M23M8-S4-S K-8E-M23M8/10,0-H01/M23M8-S4-S 1627236 PHOENIX CONTACT Plug-in connector plastic-coated on both sides View larger
Images are for illustrative purposes only. Please refer to data sheet for details

K-8E-M23M8/10,0-H01/M23M8-S4-S 1627236 PHOENIX CONTACT Plug-in connector plastic-coated on both sides

K-8E-M23M8/10,0-H01/M23M8-S4-S

1627236

PHOENIX CONTACT

10 Pcs.

Plug-in connector plastic-coated on both sides Plastic-coated cable plug, length: 10 m, outer sheath colour: orange RAL 2003 Connector in molded plastic on both sides, cable length: 10 m, shielded: yes, color of outer sheath: orange RAL 2003, Alternative product in accordance with RoHS II without Exemption 6c (Pb < 0.1 %) item no.: 1245455

Cables > Circular connector, mounting (without cable)
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
Notes on operationObserve derating curve.
Safety note
Safety noteWARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50 V AC, conductive connector housings must be grounded
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• Only use tools recommended by Phoenix Contact
• The installation notes/Design In documents online on the download page at phoenixcontact.com/products must be observed for this product.
• Operate the connector only when it is fully plugged in and interlocked.
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the minimum bending radius of the cable. Lay the cable without twisting it.
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).

Product properties
Product typeSignal and power cable

Connector
Cable specifications
Cable typeHDSLC11Y-J
Transmission speedCAT5
Transmission speed100 Mbps (Data interface)
Shieldedyes
Cable structure(5x 2.5 + 2x (2x 0.5) + (4x 0.34)C) C
External cable diameter15.50 mm ±0.5 mm
Outer sheath, materialPUR
Material wire insulationTPE
External sheath, colororange RAL 2003
Single wire, colorblack 1, black 2, black 3, black 4, green/yellow Power wires + PE
brown, violet, black 5, green Signal wires
blue, yellow, white, orange Data wires
Nominal voltage, cable1000 V (300 V signal)
Test voltage4 kV (1.5 kV signal)
Rated current26 A (Power, in accordance with DIN VDE 0298-4 Tab. 11/5, at 15°C)
8 A (Signal, according to DIN VDE 0298-4 tab. 11/5)
3.6 A (Data, according to DIN VDE 0298-4 tab. 11/5)
Smallest bending radius, fixed installation73 mm
Smallest bending radius, movable installation148 mm
Max. bending cycles1000000
Traversing path6 m
Acceleration30 m/s²
Ambient temperature (operation) for fixed installation-40 °C ... 80 °C (fixed installation)
Ambient temperature (operation) for flexible installation-20 °C ... 80 °C (flexible installation)
UL AWM style20234 / 10492 (80°C/1000 V)
Special propertiesFlexible cable conduit capable
Flame resistanceIEC 60332-1-2
Halogen-freein accordance with EN 50267-2-1
Resistance to oilEN 60811-2-1

Cable/line
Cable length10 m

ETIM for 1627236 Connectors (EC003569)
Feature Name Feature Value
With shield connection (EF002535) No
With PE-connection (EF005600) No
With thread (EF003723) Yes

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.