Isolating plugs Interrupt plug, with pure separation function, length: 39.3 mm, width: 6.2 mm, height: 78.3 mm, number of poles: 1, color: gray

Automation > Accessories/spare parts for terminals
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey3246856
Packing unit50 pc
Minimum order quantity50 pc
NoteMade to Order (non-returnable)
Catalog pagePage 491 (C-1-2017)
GTIN4046356915182
Weight per Piece (excluding packing)4.570 g
Custom tariff number85366990
Country of originPL (Poland)

General

Number of positions1
Colorgray
Insulating materialPA
Flammability rating according to UL 94V0
Degree of pollution3
Result of bending testTest passed
Bending test rotation speed10 rpm
Bending test turns135
Bending test conductor cross section/weight0.5 mm² / 0.3 kg
2.5 mm² / 0.7 kg
Tensile test resultTest passed
Conductor cross section tensile test0.5 mm²
Tractive force setpoint20 N
Conductor cross section tensile test2.5 mm²
Tractive force setpoint50 N
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width6.2 mm
Length39.3 mm
Height78.3 mm

Standards and Regulations

Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance