| Packing unit | 1 |
| Catalog page | Page 213 (C-4-2019) |
| GTIN | 4055626633879 |
| Custom tariff number | 85437090 |
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -35 °C ... 85 °C |
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 30 % ... 95 % (non-condensing) |
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Housing material | Polyamide |
|---|---|
| Color | traffic grey A RAL 7042 |
| Mounting type | DIN rail: 35 mm |
| Type | DIN rail module, one-piece |
| Supports cloud computing | yes |
| Cloud platform | Proficloud |
| Interface | Ethernet |
|---|---|
| Number | 1 |
| Connection method | RJ45 |
| Note on the connection method | pluggable |
| Transmission speed | 10/100 Mbps |
| Basic functions | Acquisition of sensor data |
| Operation | via Proficloud application and web interface |
| Operating voltage | 24 V DC (-15% ... +20% including all tolerances and ripple) |
| Operating current | ≤ 70 mA |
| Detectable values (current strength) | 100 A ... 40 kA |
| Sampling rate | 500 kHz |
| Maximum measuring period | 1 s |
| Connection name | 24 V supply |
|---|---|
| Connection method | Screw terminal block |
| Number of connections | 4 |
| Screw thread | M3 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Stripping length | 8 mm |
| Note | The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. |
| Connection name | SPD remote indication contact monitoring |
|---|---|
| Connection method | Screw terminal block |
| Screw thread | M3 |
| Stripping length | 8 mm |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Interference emission | Noise immunity test in accordance with EN 61000-6-2 Noise emission EN 61000-6-3/IEC 61000-6-3 Class B |
| Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B; DC supply lines: ±0.5 kV/±1 kV (symmetrical/asymmetrical), fieldbus cable shielding: ±1 kV |
| Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion A, 2.2 kV |
| Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
| Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
| Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V |