PHOENIX CONTACT PSM-ME-RS232/RS485-P PSM-ME-RS232/RS485-P 2744416 PHOENIX CONTACT Interface converter View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSM-ME-RS232/RS485-P 2744416 PHOENIX CONTACT Interface converter

PSM-ME-RS232/RS485-P

2744416

PHOENIX CONTACT

1 Pcs.

Interface converter Interface converter for conversion from RS-232 (V.24) to RS-422 (V.11) and RS-485, with galvanic separation, 2 channels, for rail mounting Interface converter, for converting RS-232 (V.24) to RS-422 (V.11) and RS-485, with electrical isolation, 2 channels, rail-mountable

Automation > PLC communication module
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
Note on application
Note on applicationOnly for industrial use
Utilization restriction
EMC noteEMC: class A product, see manufacturer's declaration in the download area
Utilization restriction
CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties
Product typeInterface converter
ApplicationRS-232
RS-422
RS-485
MTTF1654 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
746 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
310 Years (SN 29500 standard, temperature 40°C, operating cycle 100%)
MTBF10 Years (Telcordia standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day))
Data management status
Article revision22
Insulation characteristics
Pollution degree2

Electrical properties
Electrical isolationVCC // V.24 (RS-232) // RS-485
Maximum power dissipation for nominal condition2.04 W
Test voltage data interface/power supply1.5 kV AC
1.5 kV AC
Test voltage data interfaces1.5 kV AC
Supply
Supply voltage range18 V AC/DC ... 30 V AC/DC (via pluggable COMBICON screw terminal block)
Nominal supply voltage24 V AC/DC
Typical current consumption85 mA (24 V DC)
Max. current consumption100 mA

Connection data
Supply
Single conductor/terminal point, rigid0.2 mm² ... 2.5 mm²
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]24 ... 12
Tightening torque0.56 Nm ... 0.79 Nm

Interfaces
InterfaceRS-232/-485
Bit distortion≤ 5 %
Bit delay≤ 2.5 µs
SignalModbus
Transmission channels2 (1/1), RxD, TxD, full duplex
Data: V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
Serial transmission speed1.2; 2.4; 4.8; 7.2; 9.6; 19.2; 31.25; 38.4; 57.6; 75; 93.75; 115.2 kbps
Connection methodD-SUB 9 plug
Pin assignmentDTE/DCE switchover via switch
Transmission length15 m (shielded twisted pair)
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible12
Min. AWG conductor cross section, flexible24
Protocols supportedtransparent protocol
Data: RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
Serial transmission speed1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 75; 93.75; 115.2 kbps
Connection methodPluggable screw connection
Transmission length1200 m (shielded twisted pair)
Termination resistor390 Ω
150 Ω
390 Ω (Can be connected)
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible13
Min. AWG conductor cross section, flexible24
Protocols supportedtransparent protocol
Data: RS-485 interface in acc. with EIA/TIA-485, DIN 66259-1
Serial transmission speed1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 75; 93.75; 115.2 kbps
Connection methodPluggable screw connection
Transmission length1200 m (shielded twisted pair)
Termination resistor390 Ω
150 Ω
390 Ω (Can be connected)
Single-wire/terminal point, flexible0.2 mm² ... 2.5 mm²
Max. AWG conductor cross section, flexible14
Min. AWG conductor cross section, flexible24
Data direction switchingAutomatic control or via RTS/CTS
Protocols supportedtransparent protocol

Dimensions
Dimensional drawingxbcbzpbgso.jpg
Width22.5 mm
Height99 mm
Depth114.5 mm

Material specifications
Color (Housing)green (RAL 6021)
Material (Housing)PA 6.6-FR

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Altitude≤ 5000 m (For restrictions, see the manufacturer's declaration for altitude operation)
Permissible humidity (operation)10 % ... 95 % (non-condensing)

Approvals
CE
CertificateCE-compliant
ATEX
Identification II 3 G Ex nA IIC T4 Gc
CertificateIBExU16ATEXB004 X
NotePlease follow the special installation instructions in the documentation!
IECEx
IdentificationEx nA IIC T4 Gc
CertificateIECEx IBE 15.0034X
UL, USA/Canada
Identification508 Recognized
Class I, Div. 2, Groups A, B, C, D
Class I, Zone 2, AEx nA IIC T4
Class I, Zone 2, Ex nA IIC T4 Gc X
KC approval for South Korea
CertificateMSIP-REI-PCK-ME2744416
Corrosive gas test
IdentificationISA-S71.04-1985 G3 Harsh Group A
Shipbuilding
IdentificationDNV GL
DNV GL data
TemperatureB
HumidityA
VibrationA
EMCB
EnclosureRequired protection according to the Rules shall be provided upon installation on board

EMC data
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise immunityEN 61000-6-2:2005
Noise emissionEN 61000-6-4
Electrostatic discharge
Standards/regulationsEN 61000-4-2
Electrostatic discharge
Contact discharge± 6 kV (Test Level 3)
Discharge in air± 8 kV (Test Level 3)
CommentsCriterion B
Electromagnetic HF field
Standards/regulationsEN 61000-4-3
Electromagnetic HF field
Frequency range26 MHz ... 3 GHz (Test Level 3)
Field intensity10 V/m
CommentsCriterion A
Fast transients (burst)
Standards/regulationsEN 61000-4-4
Fast transients (burst)
Input± 2.2 kV (Test Level 3)
Signal± 2.2 kV (Test Level 3)
CommentsCriterion B
Surge current load (surge)
Standards/regulationsEN 61000-4-5
Surge current load (surge)
Input± 0.5 kV (DC supply)
Signal± 1 kV (Data line, asymmetrical)
CommentsCriterion B
Conducted interference
Standards/regulationsEN 61000-4-6
Conducted interference
Frequency range0.15 MHz ... 80 MHz
CommentsCriterion A
Voltage10 V
Emitted interference
Standards/regulationsEN 55011
CommentsClass A, industrial applications
Criteria
Criterion ANormal operating behavior within the specified limits.
Criterion BTemporary impairment to operational behavior that is corrected by the device itself.

Mounting
Mounting typeDIN rail mounting

ETIM for 2744416 PLC's (EC001423)
Feature Name Feature Value
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces other (EF003027) 0
With optical interface (EF003028) No
Supporting protocol for EtherCAT (EF017564) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) No
Supporting protocol for CAN (EF003053) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for other bus systems (EF003062) Yes
Radio standard Bluetooth (EF007178) No
Radio standard WLAN 802.11 (EF007179) No
Radio standard GPRS (EF008523) No
Radio standard GSM (EF008524) No
Radio standard UMTS (EF008525) No
IO link master (EF007298) No
Redundancy (EF003156) No
With potential separation (EF003272) No
SIL according to IEC 61508 (EF009889) None
Suitable for safety functions (EF001597) No
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None
Width (EF000008) 22.5 mm
Height (EF000040) 99 mm
Depth (EF000049) 114.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.