PHOENIX CONTACT IB IL 24 SEG/F-XC-PAC IB IL 24 SEG/F-XC-PAC 2701163 PHOENIX CONTACT Inline terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details

IB IL 24 SEG/F-XC-PAC 2701163 PHOENIX CONTACT Inline terminal

IB IL 24 SEG/F-XC-PAC

2701163

PHOENIX CONTACT

1 Pcs.

Inline terminal Inline segment terminal, variant for extreme conditions, complete with accessories (connector and marking surface), 24 V DC, with fuse Inline segment terminal, version for extreme conditions, complete with accessories (connector and labeling field), 24 V DC, with fuse

Automation > Fieldbus, decentr. periphery - power supply/segment module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Dimensions
Dimensional drawingjmtbiflfim.jpg
Width12.2 mm
Height119.8 mm
Depth71.5 mm

Notes
Note on application
Note on applicationOnly for industrial use

Interfaces
Inline local bus
Number of interfaces2
Connection methodInline data jumper
Transmission speed500 kbps / 2 Mbps (Can be used in Inline stations with these transmission speeds)

System properties
Module
ID code (dec.)none
ID code (hex)none
Register length0 bit
Required parameter data0 Byte
Required configuration data0 Byte

Product properties
Product typeI/O component
Product familyInline
Typemodular
Data management status
Article revision01
Insulation characteristics
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Electrical properties
Test section5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V AC 50 Hz 1 min.
5 V supply, outgoing remote bus/7.5 V supply (bus logics) 500 V AC 50 Hz 1 min.
7.5 V supply (bus logics)/24 V supply (I/O) 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional ground 500 V AC 50 Hz 1 min.
Protective circuitOverload protection, short-circuit protection in the segment circuit; Fuse 5 x 20 with 6.3 A, slow-blowFuses with other values can also be used. The maximum fuse value is 8 A.For fuses with a value greater than 2 A, only slow-blow fuses may be used.
Surge protection; Protective elements in the power terminal or the bus coupler
Reverse polarity protection; Protective elements in the power terminal or the bus coupler
FuseSI 5 x 20 6, 300 AT (in scope of delivery)
Supply
Communications power UL7.5 V DC
Potentials: Main circuit supply (UM)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current drawmax. 8 A (nominal value)
typ. 6 A (The terminal is supplied with a 6.3 A slow-blow fuse. In the event of an increased total current in the potential jumpers UMand US, the circuit must be protected through the use of higher rated fuses (max. 8 A, slow-blow).)
Potentials: Segment circuit supply (US)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)

Connection data
Connection technology
Connection nameInline connector
Conductor connection
Connection methodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm
Inline connector
Connection methodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 55 °C (Standard)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
GRP_Temperature classT2 (-40 °C ... 55 °C, EN 50155)

Mounting
Mounting typeDIN rail mounting

ETIM for 2701163 PLC's (EC001600)
Feature Name Feature Value
Supply voltage DC (EF007534) 19.2 V
Voltage type (supply voltage) (EF002991) DC
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 0
With optical interface (EF003028) No
System accessory (EF004118) Yes
Degree of protection (IP) (EF005474) IP20
Type of electric connection (EF003961) Other
With potential separation (EF003272) Yes
With power supply module (EF003993) No
Suitable as segment module (EF004104) Yes
Remote module (EF006653) No
Fieldbus connection over separate bus coupler possible (EF004002) Yes
Bus diagnosis possible (EF003989) No
Suitable for rail mounting (EF003972) Yes
Wall mounting/direct mounting (EF007020) No
Front built-in possible (EF007016) No
Rack-assembly possible (EF007018) No
Suitable for safety functions (EF001597) No
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.