PHOENIX CONTACT IB IL CNT-XC-PAC IB IL CNT-XC-PAC 2702134 PHOENIX CONTACT Inline function terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details

IB IL CNT-XC-PAC 2702134 PHOENIX CONTACT Inline function terminal

IB IL CNT-XC-PAC

2702134

PHOENIX CONTACT

1 Pcs.

Inline function terminal Inline counter module in the variant for extreme conditions, complete with accessories (connectors and marking surfaces), 1 meter input, 1 control input, 1 output, 24 VDC, 500 mA, 3-wire connection technology Inline, Function terminal, Counter input for 24 V signals: 1, Control input for 24 V signals: 1, Switching output: 1, 24 V DC, 0.5 A, Extreme conditions version, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connectors and marking fields

Automation > Fieldbus, decentr. periphery - function-/technology module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Dimensions
Dimensional drawingnmwuvoqfyi.jpg
Width24.4 mm
Height135 mm
Depth71.5 mm

Notes
Note on application
Note on applicationOnly for industrial use

Interfaces
Inline local bus
Number of interfaces2
Connection methodInline data jumper
Transmission speed500 kbps
Transmission physicsCopper

System properties
Module
ID code (dec.)191
ID code (hex)BF
Length code (hex)02
Length code (dec)02
Process data channel32 bit
Input address area4 Byte
Output address area4 Byte
Register length4 Byte
Required parameter data1 Byte
Required configuration data5 Byte

Input data
Counter:
Input nameCounter input for 24 V signals
Connection methodSpring-cage connection
Connection technology2-, 3-conductor
Number of inputs1 (only one counter input can be used, either for 24 V or for 5 V signals)
Operating modeEvent counting, frequency/time measurement
Input voltage24 V DC (Nominal voltage)
30 V DC (maximum)
Input voltage range "0" signal0 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Input frequencymax. 100 kHz
Input currenttyp. 5 mA
Input resistanceapprox. 5.7 kΩ
Counter:
Input nameCounter input for 5 V signals
Connection methodSpring-cage connection
Connection technology2-conductor (shielded), external 5 V supply
Number of inputs1 (only one counter input can be used, either for 24 V or for 5 V signals)
Operating modeEvent counting, frequency/time measurement
Input voltage5 V DC (Nominal voltage)
8 V DC (maximum)
Input voltage range "0" signal0 V ... 1.5 V
Input voltage range "1" signal3.5 V ... 8 V
Input frequencymax. 100 kHz
Input currenttyp. 5 mA
Input resistanceapprox. 1.7 kΩ

Output data
Digital:
Output nameSwitching output
Connection methodSpring-cage connection
Connection technology2-conductor
Number of outputs1
Protective circuitShort-circuit protection; Yes, short-circuit-proof (automatically switched on again)
Overload protection
Output voltage24 V DC (Nominal voltage)
Output currentmax. 0.5 A (Nominal current)
Nominal load, inductivemax. 12 VA (1.2 H, 48 Ω)
Nominal load, lampmax. 12 W
Nominal load, ohmicmax. 12 W (48 Ω)
Reverse voltage resistance to short pulsesReverse voltage proof
Behavior in the event of ohmic overloadAuto restart after eliminating the overload
Behavior with inductive overloadOutput can be destroyed
Behavior in the event of lamp overloadAuto restart after eliminating the overload
Overcurrent shut-downmin. 0.7 A

Product properties
Product typeI/O component
Product familyInline
Typemodular
Scope of deliveryincluding Inline connectors and marking fields
Operating modeProcess data operation with 2 words
Special propertiesExtreme conditions version
Diagnostics messagesSensor supply short-circuit
Sensor supply overload
Data management status
Article revision01

Electrical properties
Potentials: Communications power (UL)
Supply voltage7.5 V DC (via voltage jumper)
Current drawmax. 50 mA
typ. 40 mA
Power consumptionmax. 0.375 W (at UL)
Potentials: Segment circuit supply (US)
Supply voltage24 V DC (via voltage jumper)
Current drawmax. 1 A
min. 0 A (without connected peripherals)
Supply:
DesignationPower supply for sensors
Supply voltage24 V DC (generated from segment supply US)
Electrical isolation/isolation of the voltage ranges
Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O)500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V supply (bus logic)/functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection data
Connection technology
Connection nameInline connector
Conductor connection
Connection methodSpring-cage connection
Conductor cross section rigid0.08 mm² ... 1.5 mm²
Conductor cross section flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm
Inline connector
Connection methodSpring-cage connection
Conductor cross section, rigid0.08 mm² ... 1.5 mm²
Conductor cross section, flexible0.08 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16
Stripping length8 mm

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-25 °C ... 55 °C (Standard)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of protectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)

Standards and regulations
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting
Mounting typeDIN rail mounting

ETIM for 2702134 PLC's (EC001601)
Feature Name Feature Value
Number of functions (EF003244) 1
Number of HW-interfaces industrial Ethernet (EF003020) 0
Number of interfaces PROFINET (EF006932) 0
Number of HW-interfaces RS-232 (EF003021) 0
Number of HW-interfaces RS-422 (EF003022) 0
Number of HW-interfaces RS-485 (EF003023) 0
Number of HW-interfaces serial TTY (EF003024) 0
Number of HW-interfaces parallel (EF003026) 0
Number of HW-interfaces wireless (EF006933) 0
Number of HW-interfaces USB (EF003025) 0
Number of HW-interfaces other (EF003027) 0
With optical interface (EF003028) No
Supporting protocol for EtherCAT (EF017564) No
Supporting protocol for TCP/IP (EF003050) No
Supporting protocol for PROFIBUS (EF003052) Yes
Supporting protocol for CAN (EF003053) No
Supporting protocol for INTERBUS (EF003054) No
Supporting protocol for ASI (EF003051) No
Supporting protocol for KNX (EF003055) No
Supporting protocol for Modbus (EF003057) No
Supporting protocol for Data-Highway (EF003058) No
Supporting protocol for DeviceNet (EF003059) No
Supporting protocol for SUCONET (EF003060) No
Supporting protocol for LON (EF003017) No
Supporting protocol for PROFINET IO (EF007525) No
Supporting protocol for PROFINET CBA (EF007524) No
Supporting protocol for SERCOS (EF006657) No
Supporting protocol for Foundation Fieldbus (EF007522) No
Supporting protocol for EtherNet/IP (EF007521) No
Supporting protocol for AS-Interface Safety at Work (EF007519) No
Supporting protocol for DeviceNet Safety (EF007520) No
Supporting protocol for INTERBUS-Safety (EF006662) No
Supporting protocol for PROFIsafe (EF007526) No
Supporting protocol for SafetyBUS p (EF007527) No
Supporting protocol for other bus systems (EF003062) No
IO link master (EF007298) No
System accessory (EF004118) Yes
Function block restart blockage (EF007212) No
Function block automatic reset (EF007208) No
Contactor control function block (EF007467) No
Function block emergency stop (EF007211) No
Function block contactless working protection installation (EF007209) No
Function block affirm push button (EF007214) No
Function block 2-hand switching (EF007215) No
Function block operating mode selection (EF007210) No
Function block access control (EF007213) No
Degree of protection (IP) (EF005474) IP20
Fieldbus connection over separate bus coupler possible (EF004002) Yes
Frequency measurement (EF000599) Yes
Suitable for rail mounting (EF003972) Yes
Wall mounting/direct mounting (EF007020) No
Front built-in possible (EF007016) No
Rack-assembly possible (EF007018) No
Suitable for safety functions (EF001597) No
SIL according to IEC 61508 (EF009889) None
Performance level according to EN ISO 13849-1 (EF007399) None
Appendant operation agent (Ex ia) (EF004141) No
Appendant operation agent (Ex ib) (EF004142) No
Explosion safety category for gas (EF003997) None
Explosion safety category for dust (EF003998) None

Product Datasheet