View larger
ILB BT ADIO MUX
2702875
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2702875 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 467 (C-6-2017) |
| GTIN | 4055626369846 |
| Weight per Piece (excluding packing) | 630.000 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 95 % |
| Air pressure (operation) | 795 hPa ... 1080 hPa (up to 2000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
| Degree of protection | IP20 |
| Wireless standard | Based on Bluetooth 4.0 |
|---|---|
| Modulation type | GFSK (Gaussian Frequency Shift Keying) |
| Antenna connection method | RSMA (female) |
| Frequency range | 2.402 GHz ... 2.48 GHz (ISM bandwidth) |
| Transmission power | 5 dBm |
| Receiver sensitivity | -95 dBm |
| Connection method | Inline connector |
|---|---|
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30.5 V DC (via power connector) |
| Current consumption | 60 mA (at 24 V DC, at 25 °C) |
| Type of protection | Polarity protection, surge protection |
| Input name | Digital inputs |
|---|---|
| Connection method | Spring-cage connection |
| Connection technology | 1-wire |
| Number of inputs | 16 |
| 16 | |
| Input voltage range "0" signal | < 5 V |
| Input voltage range "1" signal | > 15 V |
| Typical input current per channel | 2.3 mA |
| Output name | Digital outputs |
|---|---|
| Connection method | Spring-cage connection |
| Connection technology | 1-wire |
| Number of outputs | 16 |
| Type of protection | Short-circuit protection, overload protection, protected against reverse voltages |
| Nominal output voltage | 24 V DC |
| Output current | 8 A |
| Maximum output current per channel | 500 mA |
| Nominal load, inductive | 12 VA (1.2 H, 50 Ω) |
| Nominal load, lamp | 12 W |
| Nominal load, ohmic | 12 W (48 Ω) |
| Description of the input | Single ended |
|---|---|
| Input name | Analog inputs |
| Number of inputs | 2 |
| Type of protection | Surge voltage |
| Measured value resolution | 12 bits |
| Current input signal | 0 mA ... 20 mA |
| Input resistance current input | 50 Ω |
| Voltage input signal | 0 V ... 10 V |
| Input resistance of voltage input | 130 kΩ |
| Number of outputs | 2 |
|---|---|
| Output name | Analog outputs |
| DAC resolution | 12 Bit |
| Current output signal | 0 mA ... 20 mA |
| Load/output load current output | ≤ 500 Ω |
| Voltage output signal | 0 V ... 10 V |
| Load/output load voltage output | ≥ 2 kΩ |
| Housing material | PA 6.6-FR |
|---|---|
| Mounting type | DIN rail |
| Net weight | 630 g |
| Note on weight specifications | one module, incl. connector, without antenna |
| Degree of pollution | 2 |
| MTTF | 1458 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| 557 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
| 219 Years (Telcordia standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
| Diagnostics messages | Short-circuit / overload of the digital outputs LED |
| Wireless connection FS LED | |
| Logic and actuator voltage LED | |
| Link quality of the wireless connection 4 LEDs | |
| Delay time | ≤ 10 ms (Latency, typical) |
| ≤ 800 ms (Failsafe function for wireless interruption) | |
| Wireless licenses | Europe, additional countries in the e-shop |
| Wireless licences | Belgium |
| Bulgaria | |
| Denmark | |
| Germany | |
| Estonia | |
| Finland | |
| France | |
| Greece | |
| Great Britain | |
| Ireland | |
| Iceland | |
| Israel | |
| Italy | |
| Japan | |
| Canada | |
| Latvia | |
| Liechtenstein | |
| Lithuania | |
| Luxembourg | |
| Malta | |
| Netherlands | |
| Norway | |
| Austria | |
| Poland | |
| Portugal | |
| Romania | |
| Sweden | |
| Switzerland | |
| Singapore | |
| Slovakia | |
| Slovenia | |
| Spain | |
| South Africa | |
| Czech Republic | |
| Turkey | |
| Hungary | |
| USA | |
| Cyprus (rep.) | |
| Mounting type | DIN rail mounting |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Standard designation | RED directive 2014/53/EU |
| Standards/regulations | EN 300328 |
| EN 61000-6-4 | |
| EN 61000-6-2 | |
| EN 62311 | |
| EN 60950 | |
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 25g, 11 ms period, half-sine shock pulse | |
| Free from substances that could impair the application of coating | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | ± 6 kV (Test Level 3) |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 26 MHz ... 3 GHz (Test Level 3) |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Signal | ± 1 kV (Signal line, asymmetrical) |
| Standards/regulations | EN 61000-4-6 |
| Frequency range | 0.15 MHz ... 80 MHz |
| Conformance | CE-compliant |
| FCC Directive, Part 15.247 | |
| ISC Directive RSS 210 | |
| UL, USA/Canada | UL 508 Listed |
| Protection class | III |
| MIC rating | Japan MIC (RF) ID:202-LSF002 |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Feature Name | Feature Value |
|---|---|
| Number of analogue inputs (EF001994) | 2 |
| Number of analogue outputs (EF001995) | 2 |
| Analogue inputs configurable (EF008518) | No |
| Analogue outputs configurable (EF008519) | No |
| Number of digital inputs (EF001992) | 16 |
| Number of digital outputs (EF001993) | 16 |
| Digital inputs configurable (EF008516) | No |
| Digital outputs configurable (EF008520) | No |
| Input current at signal 1 (EF001428) | 0 mA |
| Type of voltage (input voltage) (EF003033) | DC |
| Type of digital output (EF003601) | Other |
| Output current at digital output (EF003218) | 0.5 A |
| Output voltage at digital output (EF003215) | 24 V |
| Short-circuit protection, digital outputs available (EF003320) | Yes |
| Analogue input, current (EF003219) | Yes |
| Analogue input, voltage (EF003221) | Yes |
| Analogue input, resistor (EF003222) | No |
| Analogue input, resistor temperature (EF003224) | No |
| Analogue input, thermocouple (EF003225) | No |
| Analogue input signal configurable (EF003227) | No |
| Analogue output, current (EF003234) | Yes |
| Analogue output, voltage (EF003235) | Yes |
| Analogue output signal configurable (EF003236) | No |
| Number of HW-interfaces industrial Ethernet (EF003020) | 0 |
| Number of interfaces PROFINET (EF006932) | 0 |
| Number of HW-interfaces RS-232 (EF003021) | 0 |
| Number of HW-interfaces RS-422 (EF003022) | 0 |
| Number of HW-interfaces RS-485 (EF003023) | 0 |
| Number of HW-interfaces serial TTY (EF003024) | 0 |
| Number of HW-interfaces parallel (EF003026) | 0 |
| Number of HW-interfaces wireless (EF006933) | 0 |
| Number of HW-interfaces other (EF003027) | 0 |
| With optical interface (EF003028) | No |
| IO link master (EF007298) | No |
| System accessory (EF004118) | Yes |
| Type of electric connection (EF003961) | Other |
| Fieldbus connection over separate bus coupler possible (EF004002) | Yes |
| Suitable for rail mounting (EF003972) | Yes |
| Wall mounting/direct mounting (EF007020) | No |
| Front built-in possible (EF007016) | No |
| Rack-assembly possible (EF007018) | No |
| Suitable for safety functions (EF001597) | No |
| Appendant operation agent (Ex ia) (EF004141) | No |
| Appendant operation agent (Ex ib) (EF004142) | No |