View larger
PSR-MC32-3NO-1NC-24-230UC-SP
2700525
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2700525 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 253 (C-6-2017) |
| GTIN | 4046356912709 |
| Weight per Piece (excluding packing) | 235.400 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
| Ambient temperature (operation) | -40 °C ... 55 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Rated control circuit supply voltage US | 24 V AC/DC ... 230 V AC/DC -15 % / +10 % |
|---|---|
| Rated control supply current IS | typ. 103 mA (24 V DC) |
| typ. 47 mA (48 V DC) | |
| typ. 38 mA (110 V AC) | |
| typ. 21 mA (230 V AC) | |
| Power consumption at US | 2.7 W (with DC) |
| 2.9 W (with AC) | |
| Apparent power | typ. 5 VA (at US) |
| Inrush current | < 80 A (Δt = 50 µs at Us) |
| Filter time | 2 ms (at A1 in the event of voltage dips at Us) |
| Protective circuit | US: surge protection 275 V varistor / 411 V suppressor diode |
| Input voltage range "0" signal | 0 V DC ... 5 V DC (for safe Off; at S10/S12/S13) |
|---|---|
| Input current range "0" signal | 0 mA ... 2 mA (for safe Off; at S10/S12/S13) |
| Inrush current | < 5 mA (with Us/Ixat S10/S12/S13) |
| > -5 mA (with Us/Ixto S22) | |
| < 10 mA (with Us/Ixat S34/S35) | |
| Current consumption | < 5 mA (at Us/Ixto S10/S12/S13/S34/S35) |
| > -5 mA (with Us/Ixto S22) | |
| Filter time | max. 1.5 ms (to S10-S12; test pulse width; at 24 V DC) |
| 7.5 ms (to S10-S12; test pulse rate; at 24 V DC) | |
| Test pulse rate = 5 x Test pulse width | |
| Voltage at input/start and feedback circuit | 24 V DC -20 % / +25 % |
| Max. permissible overall conductor resistance | 150 Ω |
| Concurrence input 1/2 | ∞ |
| Type of protection | Inputs: protection against polarity reversal, surge protection |
| Protective circuit/component | 38.6 V suppressor diode |
| Output name | Enabling current path |
|---|---|
| Output description | safety-related N/O contacts |
| Number of outputs | 3 (undelayed) |
| Contact type | 3 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 5 V AC/DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Limiting continuous current | 6 A (observe derating) |
| Inrush current | min. 10 mA |
| max. 6 A | |
| Sq. Total current | 72 A2(observe derating) |
| Switching capacity | min. 50 mW |
| Switching frequency | max. 1 Hz |
| Interrupting rating (ohmic load) max. | 1500 VA (250 V AC, τ = 0 ms) |
| For additional values, see load curve | |
| Maximum interrupting rating (inductive load) | 48 W (24 V DC, τ = 40 ms) |
| 40 W (48 V DC, τ = 40 ms) | |
| 36 W (60 V DC, τ = 40 ms) | |
| 35 W (110 V DC, τ = 40 ms) | |
| 33 W (220 V DC, τ = 40 ms) | |
| 1500 VA (250 V AC, τ = 40 ms) | |
| Mechanical service life | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 | 5 A (24 V (DC13)) |
| 5 A (250 V (AC15)) | |
| Output fuse | 6 A gL/gG |
| 4 A gL/gG (for low-demand applications) |
| Output name | Signaling current path |
|---|---|
| Output description | non-safety-related N/C contact |
| Number of outputs | 1 (undelayed) |
| Contact type | 1 signaling current path |
| Contact material | AgSnO2 |
| Switching voltage | min. 5 V AC/DC |
| max. 250 V AC/DC | |
| Limiting continuous current | 6 A |
| Inrush current | min. 10 mA |
| max. 6 A | |
| Switching capacity | min. 50 mW |
| Switching frequency | 1 Hz |
| Mechanical service life | 10x 106cycles |
| Output fuse | 6 A gL/gG |
| 4 A gL/gG (for low-demand applications) |
| Typical pickup time at US | < 200 ms (when controlled via A1) |
|---|---|
| Typical response time at US | < 150 ms (automatic start) |
| < 100 ms (manual, monitored start) | |
| Typical release time at US | < 20 ms (when actuation is via the sensor circuit) |
| Restart time | < 1 s |
| Recovery time | < 500 ms |
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 235.4 g |
| Mounting position | vertical or horizontal |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
| Operating voltage display | 1 x green LED |
| Status display | 3 x green LED |
| Connection method | Spring-cage connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN ISO 13849 |
| Performance level (PL) | e |
| Category | 4 (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Safety Integrity Level Claim Limit (SIL CL) | 3 |
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178; EN 60947-5-1 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Basic insulation 4 kV between enabling current path (23/24) and enabling current path (33/34) and signaling current path (41/42) |
| Basic insulation 4 kV between all current paths and housing | |
| Safe isolation, reinforced insulation 6 kV between all other circuits | |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 10 Hz ... 150 Hz, 2g |
| Conformance | CE-compliant |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |
| Feature Name | Feature Value |
|---|---|
| Model (EF000010) | Basic device |
| Suitable for rail mounting (EF003972) | Yes |
| With detachable clamps (EF003340) | Yes |
| Type of electric connection (EF003961) | Spring clamp connection |
| Suitable for monitoring of position switches (EF007270) | Yes |
| Suitable for monitoring of emergency-stop circuits (EF007268) | Yes |
| Suitable for monitoring of valves (EF007272) | No |
| Suitable for monitoring of optoelectronic protection equipment (EF007269) | Yes |
| Suitable for monitoring of tactile sensors (EF007271) | No |
| Suitable for monitoring of magnetic switches (EF007266) | Yes |
| Suitable for monitoring of proximity switches (EF007267) | No |
| Evaluation inputs (EF008245) | Other |
| With start input (EF003342) | No |
| With muting function (EF004057) | No |
| With feedback circuit (EF003343) | Yes |
| Release-delay (EF001129) | 0.15 s |
| Number of outputs, safety related, undelayed, with contact (EF003344) | 0 |
| Number of outputs, safety related, delayed, with contact (EF003345) | 0 |
| Number of outputs, safety related, undelayed, semiconductors (EF003346) | 0 |
| Number of outputs, safety related, delayed, semiconductors (EF003347) | 0 |
| Number of outputs, signalling function, undelayed, with contact (EF003348) | 0 |
| Number of outputs, signalling function, delayed, with contact (EF003349) | 0 |
| Number of outputs, signalling function, undelayed, semiconductors (EF003350) | 0 |
| Number of outputs, signalling function, delayed, semiconductors (EF003351) | 0 |
| Stop category according to IEC 60204 (EF007498) | Other |
| With approval for BG BIA (EF004145) | No |
| With approval according to UL (EF001783) | No |
| Width (EF000008) | 22.5 mm |
| Height (EF000040) | 117.4 mm |
| Depth (EF000049) | 114.5 mm |