| General | For HEAVYCON HC-B6 to B48 housing, HC-M-B...-MF-... module carrier frame required, crimp connection, crimp contacts not supplied as standard. |
| General | Connectors may be operated only when there is no load/voltage. |
| Assembly note | To ensure correct use, installation in housing with IP54 protection or better is required |
| The module cannot be used simultaneously with the HC-B..-TMB-SD-IP65 and HC-B..-TMS-SD-IP65 protective covers. |
| Product type | Modular contact insert |
| Series | HC-M-04 |
| Application | Power |
| Number of positions | 4 |
| Connection profile | 4 |
| Contact numbering | 1 - 4 |
| Number of module slots | 1 |
| No. of power contacts | 4 |
| No. of control contacts | 0 |
| Contact material type | turned |
| Data management status | |
| Article revision | 02 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Connection technology | |
| Connection technology | Crimp connection |
| Connection in acc. with standard | IEC / EN |
| Conductor connection | |
| Conductor cross section | 1.5 mm² ... 6 mm² |
| Connection cross section AWG | 16 ... 10 |
| Stripping length of the individual wire | 9 mm (9.6 mm (4-6 mm²)) |
| 14 mm (4 ... 6 mm²) | |
| Dimensional drawing | ![]() |
| Width | 34.2 mm |
| Height | 44.6 mm |
| Length | 14.6 mm |
| Mechanical characteristics | |
| Minimum housing height | 52 mm |
| Contact diameter | 4 mm |
| Rated voltage (III/2) contacts | 1000 V |
| Rated voltage (III/3) | 690 V |
| Rated surge voltage (III/2) | 8 kV |
| Rated surge voltage (III/3) | 6 kV |
| Rated surge voltage | 6 kV |
| Rated current | 40 A |
| Mechanical data | |
| Insertion/withdrawal cycles | ≥ 500 |
| Flammability rating according to UL 94 | V0 |
| Contact material | Copper alloy |
| Contact surface material | Ag |
| Contact carrier material | PC |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Ambient conditions | |
| Ambient temperature (operation) | -40 °C ... 125 °C |
| Testing | |
| Standards/regulations | PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3) |
| Feature Name | Feature Value |
|---|---|
| Number of power contacts (EF012216) | 4 |
| Number of control contacts (EF012217) | 0 |
| Contact insert without contacts (EF007324) | Yes |
| Contact type (EF001587) | Pin |
| Number of poles (EF001391) | 4 |
| Diameter plug-in contact (EF007320) | 4 mm |
| Rated current In (EF008250) | 40 A |
| Ambient temperature (EF002386) | 125 °C |
| Operating temperature (EF002393) | -40 °C |
| Rated voltage (EF000228) | 690 V |
| Rated surge voltage (EF002993) | 6 kV |
| Over voltage category (EF006785) | III |
| Pollution degree (EF006786) | 3 |
| Type of electric connection (EF003961) | Crimp connection |
| With wire protection (EF000550) | No |
| Connectable conductor cross section fine-strand without cable end sleeve (EF007341) | 1.5 mm² |
| Connectable conductor cross section multi-wired (EF007343) | 1.5 mm² |
| Material of contact surface (EF004020) | Silver |
| Material of contact insert (EF008521) | Other |
| Material contact (EF007544) | Copper |
| Inflammability class of insulation material according to UL94 (EF002521) | V0 |
| With protective conductor (EF007468) | No |
| Min. number of insertion cycles (EF012212) | 500 |
| Width (EF000008) | 14.6 mm |
| Height (EF000040) | 34.1 mm |
| Depth (EF000049) | 44.2 mm |