PHOENIX CONTACT HC-COM-Q4/2-I-CT-F-PL 100 HC-COM-Q4/2-I-CT-F-PL 100 1556162 PHOENIX CONTACT Contact insert, number of poles: 4+2+PE, size: COM, power .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

HC-COM-Q4/2-I-CT-F-PL 100 1556162 PHOENIX CONTACT Contact insert, number of poles: 4+2+PE, size: COM, power ..

HC-COM-Q4/2-I-CT-F-PL 100

1556162

PHOENIX CONTACT

1 Pcs.

Contact insert, number of poles: 4+2+PE, size: COM, power contacts: 4, control contacts: 2, number of connections per pole: 1, Female, Crimp connection, 400 V, 40 A, 1.5 mm2 ... 10 mm2, application: Power/signal, Units/emb.: 100 pieces, only suitable for plastic housings Contact insert, number of poles: 4+2+PE, size: COM, power contacts: 4, control contacts: 2, number of connections per pole: 1, Female, crimped connection, 400 V, 40 A, 1.5 mm² ... 10 mm², Application: Power/Signal Contact insert, number of positions: 4+2+PE, size: COM, power contacts: 4, control contacts: 2, number of connections per position: 1, Socket, Crimp connection, 400 V, 40 A, 1.5 mm2 ... 10 mm2, application: Power/signal, Packing unit: 100 pcs

Connectors > Contact insert for rectangular connectors
Industrial plug-in connectors/interfaces

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
GeneralConnectors may be operated only when there is no load/voltage.
GeneralFor CK4,0-ED... (power circuit), CK1,6-ED... (control circuit) crimp contacts

Mounting
Assembly instructionsTo ensure correct use, installation in housing with IP54 protection or better is required
Can only be used in plastic housing

Product properties
TypeCOM
Product typeContact insert with a fixed no. of positions
Number of positions6
Connection profile4+2+PE
Contact numbering1 - 4 (power contacts)
11 - 12 (control contacts)
ApplicationPower/signal
Number of connections per position1
No. of power contacts4
No. of control contacts2
Contact material typeturned
SeriesHC-COM
Insulation characteristics
Overvoltage categoryIII
Degree of pollution3

Dimensions
Dimensional drawingvcboookntr.jpg
Width22.4 mm
Height44.1 mm
Length41.6 mm
Mechanical characteristics
Contact diameter4 mm

Connection data
Connection technology
Connection technologyCrimp connection (power contacts)
Crimp connection (control contacts)
Crimp connection (PE contact)
Number of connections per position1
Connection in acc. with standardIEC / EN
Conductor connection
Conductor cross section1.5 mm² ... 10 mm² (power contacts)
0.14 mm² ... 2.5 mm² (control contacts)
Connection cross section AWG16 ... 8 (power contacts)
26 ... 14 (control contacts)
Tightening torque0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Stripping length of the individual wire9 mm (for 1.5 ... 2.5 mm²)
9.6 mm (Power 4 ... 6 mm²)
16 mm (10 mm² power circuit)
6 mm (Signal 2.5 mm²)

Electrical properties
Rated voltage (III/3)400 V (Phase-ground power contacts)
250 V (control contacts)
690 V (Phase-phase power contacts)
Rated voltage for power contacts400/690 V
250
Rated surge voltage6 kV (Phase-phase power contacts)
4 kV (control contacts)
Rated current40 A (power contacts)
10 A (control contacts)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 500

Material specifications
Flammability rating according to UL 94V0
Contact materialCopper alloy
Contact surface materialAg (alternatively Au)
Contact carrier materialPC
Material of contact surface, power contactAg
Material of contact surface, control contactAg (alternatively Au)
Standards/regulationsPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-40 °C ... 125 °C (including heating up of contacts)

Standards and regulations
Testing
Standards/regulationsPC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

ETIM for 1556162 Connectors (EC000438)
Feature Name Feature Value
Number of power contacts (EF012216) 4
Number of control contacts (EF012217) 2
Contact insert without contacts (EF007324) Yes
Contact type (EF001587) Bus
Number of poles (EF001391) 6
Diameter plug-in contact (EF007320) 4 mm
Material connector insert (EF007545) Thermoplastic
Rated current In (EF008250) 40 A
Ambient temperature (EF002386) 125 °C
Operating temperature (EF002393) -40 °C
Rated voltage (EF000228) 400 V
Rated surge voltage (EF002993) 6 kV
Over voltage category (EF006785) III
Pollution degree (EF006786) 3
Type of electric connection (EF003961) Crimp connection
With wire protection (EF000550) No
Connectable conductor cross section fine-strand without cable end sleeve (EF007341) 1.5 mm²
Connectable conductor cross section multi-wired (EF007343) 1.5 mm²
Material of contact surface (EF004020) Other
Material of contact insert (EF008521) Thermoplastic
Material contact (EF007544) Other copper alloys
Inflammability class of insulation material according to UL94 (EF002521) V0
With protective conductor (EF007468) Yes
Min. number of insertion cycles (EF012212) 500
Width (EF000008) 22.4 mm
Height (EF000040) 44.1 mm
Depth (EF000049) 41.6 mm

Product Datasheet