PHOENIX CONTACT FP 1,27/ 50-FWL FP 1,27/ 50-FWL 1714909 PHOENIX CONTACT Plug, IDC, rated Current to 20A °C: 1.2 A, test Voltage: 500 V AC, n.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

FP 1,27/ 50-FWL 1714909 PHOENIX CONTACT Plug, IDC, rated Current to 20A °C: 1.2 A, test Voltage: 500 V AC, n..

FP 1,27/ 50-FWL

1714909

PHOENIX CONTACT

160 Pcs.

Plug, IDC, rated Current to 20A °C: 1.2 A, test Voltage: 500 V AC, number of poles: 50, step: 1.27 mm, color: black, surface contacts: Gold IDC plug plug, rated current: 1.2 A, Test voltage: 500 V AC, number of poles: 50, pitch: 1.27 mm, number of rows: 1, color: black, contact surface: Gold, contact type: Female connection, You will find pre-made samples in the "Accessories" tab. IDC plug plug, rated current: 1.2 A, Test voltage: 500 V AC, number of poles: 50, pitch: 1.27 mm, color: black, contact surface: Au, type of contact connection: Female, You will find pre-made samples in the "Accessories" tab.

Connectors > Printed circuit board connector
PCB Connectors (PCC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
A note on the applicationPlease note the indication for use for your own clothing in the unloading area.
Note on documentationCurrent documents such as 3D models, product family diagrams, data sheets or packaging diagrams are available in the Download Center.
Observation regarding the operationThe additional operating stress is obtained depending on the application by taking into account the leakage lines and insulation distances in air within the framework of the insulation requirements according to IEC 60664-1.

Item Properties
Product TypeIDC plug plug
Product FamilyFR 1,27/...-FWL
Number of poles50
Step1.27 mm
Number of rows2
Number of potentials50
Data Maintenance Status
Article Review01

Electrical Properties
Nominal Current IN1.2 A IEC 60512-5-2:2002-02 (at 20 °C 50 poles)
Contact resistance10 mΩ
Test voltage500 V AC IEC 60512-4-1:2003

Connection data
Connecting Conductors
Connection typeScroll connection
AWG Conductor Section30
Blockade
Locking systemLace lock
Clamping flangeLocking trigger

Dimensions
Step1.27 mm
Width [w]37.91 mm
Height [h]4.2 mm
Length [l]13.65 mm
application
Shifting the Center± 0.7 mm on longitudinal and transverse axis
Angular Tolerance± 4° on longitudinal axis
± 2° in transverse axis

Material Data
Material data - contact
ObservationWEEE/RoHS compliant, filament-free according to IEC 60068-2-82/JEDEC JESD 201
Contact materialCu Alloy
Surface CharacteristicsSelective Coating
Metal surface contact area (top layer)Gold (Au)
Metal Surface Contact Area (Middle Layer)Nickel (Ni) Palladium-Nickel, (PoNi)
Material data - housing
Color (Housing)Black (9005)
Insulating materialLCP
Insulating material groupIIIb
CTI according to IEC 60112175
Flammability class according to UL 94V0

Connectors
Connection 1
Insulating materialLCP
CTI according to IEC 60112175

Electrical Testing
Thermal Test Test Group C
Test SpecificationIEC 60512-5-2:2002-02
Number of poles tested50
Insulation resistance
Test SpecificationIEC 60512-3-1:2002-02
Insulation Resistance Adjacent Poles≥ 10 GΩ

Mechanical testing
Forces when plugging in and unplugging
ResultApproved Test
Number of cycles500
Plug-in force approx.0.5 N
Power when unplugging by pole approx.0.5 N

Environmental and life-life conditions
Vibration test
Test SpecificationIEC 60068-2-6:2007-12
frequency10 - 2000 - 10 Hz
Sweep speed1 octave/min
Amplitude1.5 mm (10 Hz ... 60.1 Hz)
Acceleration20g (60.1 Hz ... 2000 Hz)
Test duration per axis2.5 h
Test DirectionsX, Y, and Z axes
Durability Test
Test SpecificationIEC 60512-9-1:2010-03 (compliance)
Bearable shock voltage at sea level0.8 kV
Contact Resistance R110 mΩ
Contact Resistance R210 mΩ
Plug Cycles500
Insulation Resistance Adjacent Poles≥ 10 GΩ
Climate Essay
Test SpecificationIEC 60512-11-7:2003-05
Corrosion fatigueMethod 1, 10 days
Bearable AC voltage500 V AC
Crash
Test SpecificationIEC 60068-2-27:2008-02
Shock TypeSemi-sinusoidal
Acceleration50g
Duration of the crash11 ms
Test DirectionsX, Y, and Z axes (pos. and neg.)
Environmental conditions
Ambient Temperature (Service)-55 °C ... 125 °C
Ambient Temperature (Storage/Transport)-40 °C ... 70 °C
Relative humidity of the air (storage/transport)30 % ... 70 %
Ambient Temperature (Mounting)-5 °C ... 100 °C

Packaging Information
Type of packagingTray

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.