View larger
FL NAT 2008
2702881
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2702881 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 328 (C-6-2019) |
| GTIN | 4055626376622 |
| Weight per Piece (excluding packing) | 380.000 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | 0 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
| Air pressure (operation) | 86 kPa ... 108 kPa (1500 m above sea level) |
| Air pressure (storage/transport) | 86 kPa ... 108 kPa |
| Interface | Ethernet (RJ45) |
|---|---|
| No. of ports | 8 (RJ45 ports) |
| Note on the connection method | Auto negotiation and autocrossing |
| Transmission physics | Copper |
| Transmission speed | 10/100 Mbps |
| Transmission length | 100 m (per segment) |
| Signal LEDs | Data receive, link status |
| Basic functions | Router for standard routing, NAT, 1:1-NAT and port forwarding |
|---|---|
| Management | Web-based management (HTTP/HTTPS) |
| SNMPv1/v2/v3 | |
| Command-line interface (Telnet, SSH) | |
| Diagnostic functions | RMON History |
| LLDP (Link Layer Discovery Protocol) | |
| SNMP-Traps | |
| N:1-Portmirroring | |
| ACD (Address Conflict Detection) | |
| SysLog | |
| CRC-Surveillance | |
| Filter functions | Quality of Service (8 priority classes) |
| Port-Priorisierung | |
| VLAN (up to 8 VLANs) | |
| IGMP Snooping/Querier (v1/v2) | |
| Auto-Query-Port | |
| Extended Multicast Filtering | |
| NAT functions | 1:1-NAT |
| Virtual-NAT | |
| IP-Masquerading | |
| Port forwarding | |
| Redundancy | MRP (Media Redundancy Protocol) |
| RSTP (Rapid Spanning Tree Protocol) | |
| MAC address table | 8k |
| IP parameterization | DHCP-Client |
| DHCP server (port based) | |
| BootP | |
| PROFINET conformance class | Conformance-Class A |
| Time synchronization | SNTP (Simple Network Time Protocol) |
| Status and diagnostic indicators | LEDs: US (power supply), 2 LEDs per Ethernet port (Link/Activity and Speed) |
| Cascading depth | Network, linear, and star structure: any |
|---|---|
| Maximum conductor length (twisted pair) | 100 m |
| Supply voltage | 24 V DC (single) |
|---|---|
| Residual ripple | 3.6 VPP(within the permitted voltage range) |
| Supply voltage range | 18 V DC ... 32 V DC |
| Typical current consumption | 180 mA (at US= 24 V DC and 25 °C ambient temperature) |
| Max. current consumption | 0.35 A (At US= 18 V DC and 60°C ambient temperature) |
| Current consumption | 180 mA |
| Mounting type | DIN rail |
|---|---|
| Type AX | Book type |
| Net weight | 378 g |
| Housing material | Polycarbonate fiber reinforced |
| Note | Support by phone or on-site (fee is charged) |
| Special properties | 1:1-NAT, Virtual NAT, IP-Masquerading |
| MTTF | 507.8 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| 246.55 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
| 56.66 Years (SN 29500 standard, temperature 55 °C, operating cycle 100 % (7 days a week, 24 hours a day)) |
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.08 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.08 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 28 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 7 mm |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Interference emission | EN 61000-6-2 EN 61000-6-4 (interference) Class A |
| Conducted noise emission | EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A |
| Immunity to surge | EN 61000-6-2 EN 61000-4-5 (surge) Criterion B |
| Immunity to burst | EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A |
| Immunity to EF | EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A |
| Immunity to ESD | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
| Immunity to conducted interference | EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A |
| Type of test | Free fall in accordance with EN 61131-2 |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 |
| Vibration (storage/transport) | 2g, criterion 1 according to IEC 60068-2-6 |
| Free from substances that could impair the application of coating | Yes |
| Vibration (operation) | 2g, according to IEC 60068-2-6 |
| Shock (operation) | 30g (EN 60068-2-27) |
| UL, USA | UL 61010-1, Ed.3 / UL 61010-2-201, Ed.1 |
| UL, Canada | CSA C22.2 NO.61010-2-201:14, Ed.1 / CSA C22.2 NO.61010-1-12, Ed.3 |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |
| eCl@ss 10.0.1 | 19170401 |
|---|---|
| eCl@ss 5.0 | 19030100 |
| eCl@ss 5.1 | 19030100 |
| eCl@ss 6.0 | 19170100 |
| eCl@ss 7.0 | 19170106 |
| eCl@ss 8.0 | 19170106 |
| eCl@ss 9.0 | 19170106 |
| Feature Name | Feature Value |
|---|---|
| Ethernet (EF003535) | Yes |
| Number of other ports (EF007643) | 8 |
| Mounting method (EF000003) | Other |
| Manageable (EF004912) | Yes |
| Degree of protection (IP) (EF005474) | IP20 |
| Height (EF000040) | 130.592254 mm |
| Width (EF000008) | 45 mm |
| Depth (EF000049) | 125.1 mm |