View larger
FA MCR-EX-DS-I-I-OLP
2908800
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2908800 |
|---|---|
| Packing unit | 1 pc |
| GTIN | 4055626357225 |
| Weight per Piece (excluding packing) | 353.500 g |
| Custom tariff number | 85437090 |
| Country of origin | DE (Germany) |
| Ambient temperature (operation) | -40 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Maximum altitude | < 5000 m (Above sea level) |
| Description of the input | Current measuring input |
|---|---|
| Current input signal | 4 mA ... 20 mA |
| Max. input current | 200 mA |
| Description of the input | HART |
| Current input signal | up to 4x HART signals |
| Maximum transmission error | 0.1 % (of final value) |
|---|---|
| Maximum temperature coefficient | < 0.02 %/K |
| Noise emission | IEC 61326, class B |
| Housing material | Aluminum / polycarbonate |
| Mounting position | Max. viewing angle range +/- 45° from the centre line of the display in every direction |
| Conformance | CE-compliant |
| ATEX | II 2G Ex ib IIC T6 Gb |
| IECEx | Ex ib IIC T6 Gb |
| UL, USA/Canada | UL 61010 Listed |
| Noise emission | IEC 61326, class B |
|---|---|
| Conformance | CE-compliant |
| ATEX | II 2G Ex ib IIC T6 Gb |
| IECEx | Ex ib IIC T6 Gb |
| UL, USA/Canada | UL 61010 Listed |
| DNV GL-Temperature | B |
| DNV GL-Humidity | B |
| DNV GL-Vibration | A |
| DNV GL-EMC | B |
| DNV GL-Enclosure | - (panel housing IP65 at front, IP20 at rear, Field housing IP67) |
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |