View larger
DD31H 2,2/18-V-3,81-X
1340627
PHOENIX CONTACT
50 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Product Line | CONNEXIS Connectors S |
| Product Type | PCB header |
| Product range | DD31H 2,2/.. -V |
| Number of poles | 18 |
| Steps | 3.81 mm |
| Number of rows | 2 |
| Pinout plot | Linear pinout |
| Number of pins per potential | 1 |
| Rated Current IN | 8 A |
| Rated voltage UN | 160 V |
| Degree of pollution | 3 |
| Contact resistance | 5 mΩ |
| Reference voltage (III/3) | 160 V |
| Rated Shock Resistance Voltage (III/3) | 2.5 kV |
| Rated Voltage (III/2) | 160 V |
| Rated Shock Withstand Voltage (III/2) | 2.5 kV |
| Reference voltage (II/2) | 320 V |
| Rated Shock Withstand Voltage (II/2) | 2.5 kV |
| Mounting Type | Wave Welding |
| Pinout plot | Linear pinout |
| Material indication - contact | |
| Note | WEEE/RoHS compliant, trichite-free according to IEC 60068-2-82/JEDEC JESD 201 |
| Contact material | Cu Alloy |
| Surface quality | Galvanic tinning |
| Metal surface, contact area (top layer) | Tin (3 - 5 μm Sn) |
| Metal surface, contact area (middle layer) | Nickel (1.3 - 3 μm Ni) |
| Metal surface, welding area (top layer) | Tin (3 - 5 μm Sn) |
| Metal surface, welding area (middle layer) | Nickel (1.3 - 3 μm Ni) |
| Material indication - housing | |
| Colors (Cases) | Black (9005) |
| Insulating material | PBT |
| Insulation Group | II |
| CRI according to IEC 60112 | 400 ≤ ITC |
| Flammability class according to UL 94 | V0 |
| Contact note | These connectors are without switching power (COC) in accordance with DIN EN 61984. If used correctly, they should not be plugged in, unplugged under load, or powered on. |
| Application Note | The current depends on the crimp contact used and the conductor cross-section. |
| Dimensioned drawing | |
| Steps | 3.81 mm |
| Width [w] | 44.48 mm |
| Height [h] | 25.4 mm |
| Length [l] | 14.43 mm |
| Mounting height | 21.6 mm |
| Welding pin length [P] | 3.8 mm |
| PCB design | |
| Drilling Diameter | 2 mm |
| 1.1 mm | |
| Visual inspection | |
| Control Specification | DIN EN 60512-1-1:2003-01 |
| Result | Successful test |
| Dimension control | |
| Control Specification | DIN EN 60512-1-2:2003-01 |
| Result | Successful test |
| Resistance of inscriptions | |
| Control Specification | DIN EN 60068-2-70:1996-07 |
| Result | Successful test |
| Polarization and keying | |
| Control Specification | DIN EN 60512-13-5:2006-11 |
| Result | Successful test |
| Using contact holders | |
| Control Specification | DIN EN 60512-15-1:2009-03 |
| Contact holder used Requirement >20 N | Successful test |
| Plug-in and Shrink Forces | |
| Result | Successful test |
| Number of cycles | 25 |
| Approx. mating force per pole | 6 N |
| Removal force per pole approx. | 6 N |
| Thermal Testing Test Group C | |
| Control Specification | DIN EN 60512-5-1:2003-01 |
| Number of poles tested | 20 |
| Insulation resistance | |
| Control Specification | DIN EN 60512-3-1:2003-01 |
| Insulation resistance of neighboring poles | > 5 MΩ |
| Air Distances and Trailing Lines | |
| Control Specification | DIN EN 60664-1 (VDE 0110-1):2008-01 |
| Insulation Group | II |
| Resistance to leakage currents (DIN EN 60112 (VDE 0303-11)) | ITC≥400 to <600 |
| Rated Insulation Voltage (III/3) | 160 V |
| Rated Shock Resistance Voltage (III/3) | 2.5 kV |
| minimum value of distance in air - non-homogeneous field (III/3) | 1.5 mm |
| minimum creepage value (III/3) | 2.2 mm |
| Rated Insulation Voltage (III/2) | 160 V |
| Rated Shock Voltage (III/2) | 2.5 kV |
| minimum value of distance in air - non-homogeneous field (III/2) | 1.5 mm |
| minimum creepage value (III/2) | 1.5 mm |
| Rated Insulation Voltage (II/2) | 320 V |
| Rated Shock Withstand Voltage (II/2) | 2.5 kV |
| minimum value of distance in air - non-homogeneous field (II/2) | 1.5 mm |
| minimum creepage value (II/2) | 2.2 mm |
| Vibration Resistance Test | |
| Control Specification | DIN EN 60068-2-6 (VDE 0468-2-6):2008-10 |
| Frequency | 10 - 150 - 10 Hz |
| Scan Speed | 1 octave/min |
| Amplitude | 0.35 mm (10 Hz ... 60.1 Hz) |
| Scan Speed | 50 m/s² (60.1 Hz ... 150 Hz) |
| Inspection time per axis | 2.5 hrs |
| Lifetime test | |
| Control Specification | DIN EN 60512-9-1 (VDE 0687-512-9-1):2010-12 |
| Shock Resistance Voltage at Sea Level | 2.95 kV |
| Passage resistance R1 | 5 mΩ |
| Passage resistance R2 | 5 mΩ |
| Passage resistance R22nd floor | 5 mΩ |
| Number of mating cycles | 25 |
| Climate control | |
| Control Specification | DIN EN ISO 6988:1997-03 |
| Corrosion susceptibility | 0.2 dm3SO2about 300 dm3/40 °C/1 cycle |
| Heat sensitivity | 105 °C/168 h |
| Alternating current withstand voltage | 1.39 kV |
| Environmental conditions | |
| Ambient Temperature (Operating) | -55 °C ... 105 °C (depending on the derating curve) |
| Ambient temperature (storage/transport) | -40 °C ... 70 °C |
| Relative humidity of the air (storage/transport) | 30 % ... 70 % |
| Ambient temperature (mounting) | -5 °C ... 100 °C |
| Type of packaging | packed in a carton |
| Feature Name | Feature Value |
|---|---|
| Connector model (EF007495) | Fixed connector |
| Contact type (EF001587) | Pin |
| Number of plug-in contact rows (EF006935) | 2 |
| Modular spacing contacts (EF007326) | 3.81 mm |
| Modular spacing connections (EF006827) | 3.81 mm |
| Rated current In (EF008250) | 8 A |
| Rated voltage (EF000228) | 160 V |
| Rated surge voltage (EF002993) | 2.5 kV |
| Over voltage category (EF006785) | III |
| Pollution degree (EF006786) | 2 |
| Material of contact surface (EF004020) | Tin |
| Type of electric connection (EF003961) | Other |
| Diameter connection pin (EF006823) | 2 mm |
| Length pin (EF006825) | 3.8 mm |
| Material insulation body (EF007543) | Other |
| Housing colour (EF000136) | Black |
| Inflammability class of insulation material according to UL94 (EF002521) | V0 |
| Operating temperature (EF002393) | -55 °C |
| Type of fastening (EF002442) | Other |
| Type of banding (EF007011) | Carton (for SMD) |