MINI-PS-12-24DC/24DC/1
2866284
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2866284 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 256 (C-4-2017) |
| GTIN | 4017918960902 |
| Weight per Piece (excluding packing) | 245.700 g |
| Custom tariff number | 85044030 |
| Country of origin | CN (China) |
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Nominal input voltage range | 12 V DC ... 24 V DC |
|---|---|
| Input voltage range | 10 V DC ... 32 V DC |
| Frequency range DC | 0 Hz |
| Current consumption | 2.6 A (12 V DC) |
| 1.3 A (24 V DC) | |
| Inrush surge current | < 15 A (typical) |
| Mains buffering | typ. 3 ms (12 V DC) |
| typ. 20 ms (24 V DC) | |
| Input fuse | 6.3 A (slow-blow, internal) |
| Nominal output voltage | 24 V DC ±1 % |
|---|---|
| Setting range of the output voltage (USet) | 22.5 V DC ... 28.5 V DC (> 24 V DC, constant capacity restricted) |
| Nominal output current (IN) | 1 A (-25 °C ... 60 °C) |
| Derating | 60 °C ... 70 °C (2.5%/K) |
| Connection in parallel | Yes, for assembling redundant systems and increasing efficiency |
| Connection in series | yes |
| Residual ripple | < 30 mVPP(20 MHz) |
| Output power | 24 W |
| Typical response time | < 0.5 s |
| Peak switching voltages nominal load | < 100 mVPP(20 MHz) |
| Maximum power dissipation in no-load condition | < 1.2 W |
| Power loss nominal load max. | < 5 W |
| Net weight | 0.2 kg |
|---|---|
| Operating voltage display | Green LED |
| Efficiency | > 83 % (at 24 V DC and nominal values) |
| Insulation voltage input/output | 1.5 kV (type test) |
| 1 kV (routine test) | |
| Protection class | III |
| Degree of protection | IP20 |
| MTBF (IEC 61709, SN 29500) | |
| > 2569000 h (40 °C) | |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
| Connection method | Pluggable screw connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Connection method | Pluggable screw connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Output name | DC OK active |
|---|---|
| Output description | UOUT> 21.5 V: High signal |
| Maximum switching voltage | ≤ 24 V DC |
| Output voltage | + 24 V (Signal) |
| Continuous load current | ≤ 20 mA |
| Status display | "DC OK" LED green |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 14 |
| Tightening torque, min | 0.5 Nm |
| Tightening torque max | 0.6 Nm |
| Screw thread | M3 |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Noise emission | EN 55011 (EN 55022) |
| Noise immunity | EN 61000-6-2:2005 |
| Connection in acc. with standard | CUL |
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | 8 kV (Contact discharge) |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 80 MHz ... 3 GHz |
| Test field strength | 10 V/m |
| Standards/regulations | EN 61000-4-4 |
| Comments | Level 2 - asymmetrical cable to ground |
| Standards/regulations | EN 61000-6-3 |
| EN 61000-4-6 | |
| Frequency range | 0.15 MHz ... 80 MHz (10 V) |
| Standards/regulations | EN 61000-4-11 |
| Low Voltage Directive | Conformance with LV directive 2006/95/EC |
| Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
| Standard - Safe isolation | DIN VDE 0100-410 |
| DIN VDE 0106-101 | |
| Shipbuilding approval | DNV GL (EMC A) |
| UL approvals | UL/C-UL listed UL 508 |
| UL/C-UL Recognized UL 60950-1 | |
| UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
| Rail applications | EN 50121-4 |
| China RoHS | Environmentally Friendly Use Period = 25; |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |