1 Pcs.

Coupling relay Coupling relay for low/high demand SIL 3 applications, couples digital output signals to the periphery, 1 trip circuit, 1 warning contact, module for Safe State Off applications, test pulse filter, fuse, width: 17.5 mm, plug-in push-in terminal block

Automation > Device for monitoring of safety-related circuits
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey2981981
Packing unit1 pc
Catalog pagePage 286 (C-6-2017)
GTIN4046356448345
Weight per Piece (excluding packing)99.990 g
Custom tariff number85364900
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width17.5 mm
Height112 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitude≤ 2000 m (Above sea level)

Input data

Rated control circuit supply voltage US24 V DC -15 % / +10 %
Rated control supply current IStyp. 55 mA
Power consumption at UStyp. 1.32 W
Inrush currentmax. 100 mA
Typ. starting time with Us50 ms
Typical release time50 ms
Recovery time1 s
Operating voltage display1 x yellow LED
Protective circuitSurge protection Suppressor diode, 33 V (A1 - A2)
Maximum switching frequency0.5 Hz
Filter timemax. 5 ms (at A1 in the event of voltage dips at Us)
max. 2 ms (Test pulse width; high test pulse at A1/A2)
≥ 100 ms (Test pulse width; high test pulse at A1/A2)
Test pulse rate = 80 x Test pulse width
max. 5 ms (Test pulse width; low test pulse at A1/A2)
≥ 50 ms (Test pulse rate; low test pulse at A1/A2)
Test pulse rate = 15 x Test pulse width

Output data

Contact type1 enabling current path
1 confirmation current path
Contact materialAgCuNi, + 0.2 µm Au
Maximum switching voltage250 V AC/DC (N/O contact / N/C contact, observe the load curve)
Minimum switching voltage15 V AC/DC (N/O contact / N/C contact)
Limiting continuous current5 A (N/O contact, pay attention to the derating)
100 mA (N/C contact)
Maximum inrush current5 A (N/O contact)
100 mA (N/C contact)
Inrush current, minimum5 mA (N/O contact / N/C contact)
Sq. Total current25 A2(observe derating)
Interrupting rating (ohmic load) max.120 W (24 V DC, τ = 0 ms, N/C contact: 2.4 W)
192 W (48 V DC, τ = 0 ms, N/C contact: 4.8 W)
162 W (60 V DC, τ = 0 ms, N/C contact: 6 W)
66 W (110 V DC, τ = 0 ms, N/C contact: 11 W)
60 W (220 V DC, τ = 0 ms, N/C contact: 22 W)
1250 VA (250 V AC, τ = 0 ms, N/C contact: 25 VA)
Maximum interrupting rating (inductive load)72 W (24 V DC, τ = 40 ms, N/C contact: 2.4 W)
43 W (48 V DC, τ = 40 ms, N/C contact: 4.8 W)
41 W (60 V DC, τ = 40 ms, N/C contact: 6 W)
35 W (110 V DC, τ = 40 ms, N/C contact: 11 W)
48 W (220 V DC, τ = 40 ms, N/C contact: 22 W)
Switching capacitymin. 75 mW
Mechanical service life10x 106cycles
Output fuse5 A T fuse (N/O contact)
150 mA Fast-blow (N/C contact)

General

Relay typeElectromechanical relay with forcibly guided contacts in accordance with EN 50205
Nominal operating mode100% operating factor
Net weight99.99 g
Mounting positionany
Mounting typeDIN rail mounting
Degree of protectionIP20
IP54
Min. degree of protection of inst. locationIP54
Housing materialPBT
Housing coloryellow

Connection data

Connection methodSpring-cage connection
pluggableYes
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

Safety-related characteristic data

Stop category0
DesignationIEC 61508 - High demand
Safety Integrity Level (SIL)3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% )
DesignationIEC 61508 - Low demand
Safety Integrity Level (SIL)3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% )
DesignationEN ISO 13849
Performance level (PL)e (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 99%)
Category4 (Diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 99%)
DesignationEN 62061
Safety Integrity Level Claim Limit (SIL CL)3 (max. 10% of the entire SIL; diagnostic coverage (DC) of the control unit at A1/A2 must be ≥ 90% )
DesignationEN 50156
Safety Integrity Level (SIL)3

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178/VDE 0160
Rated insulation voltage250 V AC
Rated surge voltage/insulationSafe isolation, reinforced insulation 6 kV between the control circuits (A1/A2), (21/22), (13/14)
Degree of pollution2
Overvoltage categoryIII
Shock15g
Vibration (operation)10 Hz ... 150 Hz, 2g
ConformanceCE-compliant

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


ETIM for 2981981 Relays (EC001449)
Feature Name Feature Value
Model (EF000010) Basic device
Suitable for rail mounting (EF003972) Yes
With detachable clamps (EF003340) Yes
Type of electric connection (EF003961) Spring clamp connection
Suitable for monitoring of emergency-stop circuits (EF007268) No
Suitable for monitoring of valves (EF007272) No
Suitable for monitoring of optoelectronic protection equipment (EF007269) No
Suitable for monitoring of tactile sensors (EF007271) No
Suitable for monitoring of magnetic switches (EF007266) No
Suitable for monitoring of proximity switches (EF007267) No
Evaluation inputs (EF008245) Other
With start input (EF003342) No
With muting function (EF004057) No
With feedback circuit (EF003343) No
Release-delay (EF001129) 0.05 s
Number of outputs, safety related, undelayed, with contact (EF003344) 0
Number of outputs, safety related, delayed, with contact (EF003345) 0
Number of outputs, safety related, undelayed, semiconductors (EF003346) 0
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, with contact (EF003348) 0
Number of outputs, signalling function, delayed, with contact (EF003349) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 0
Number of outputs, signalling function, delayed, semiconductors (EF003351) 0
Stop category according to IEC 60204 (EF007498) Other
With approval for BG BIA (EF004145) No
With approval according to UL (EF001783) No
Width (EF000008) 17.5 mm
Height (EF000040) 112 mm