View larger
PSR-PC40-2NO-1DO-24DC-SP
2700589
PHOENIX CONTACT
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Orderkey | 2700589 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 283 (C-6-2017) |
| GTIN | 4046356916141 |
| Weight per Piece (excluding packing) | 196.000 g |
| Custom tariff number | 85364900 |
| Country of origin | DE (Germany) |
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
| Ambient temperature (operation) | -40 °C ... 70 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
| Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
| Maximum altitude | ≤ 2000 m (Above sea level) |
| Rated control circuit supply voltage US | 24 V DC -15 % / +10 % (A1/A2) |
|---|---|
| 20.4 V DC ... 26.4 V DC | |
| Rated control supply current IS | typ. 75 mA (depending on load M1 +100 mA) |
| Power consumption at US | typ. 1.8 W |
| Inrush current | typ. 400 mA (Δt s) |
| Filter time | max. 2 ms (at A1-A2; test pulse width) |
| ≥ 100 ms (at A1-A2; test pulse rate) | |
| Protective circuit | Serial protection against polarity reversal 33 V suppressor diode |
| Input name | Start circuit |
|---|---|
| Number of inputs | 2 (Non-safety-related start inputs: Y1/Y2) |
| Inrush current | < 10 mA |
| Current consumption | < 5 mA |
| Voltage at input/start and feedback circuit | 24 V DC -15 % / +10 % |
| Max. permissible overall conductor resistance | 150 Ω |
| Output name | Enabling current path |
|---|---|
| Output description | 2 NO contacts each in series, without delay, floating |
| Number of outputs | 2 (safety-related N/O contacts: 13/14, 23/24) |
| Contact type | 2 enabling current paths |
| Contact material | AgSnO2 |
| Switching voltage | min. 12 V AC/DC |
| max. 250 V AC/DC (Observe the load curve) | |
| Limiting continuous current | 6 A (High demand) |
| 4 A (Low demand) | |
| Inrush current | min. 3 mA |
| max. 6 A | |
| Sq. Total current | 60 A2(observe derating) |
| Switching capacity | min. 60 mW |
| Switching frequency | max. 0.5 Hz |
| Mechanical service life | 10x 106cycles |
| Switching capacity according to IEC 60947-5-1 | 4 A (24 V (DC13)) |
| 5 A (250 V (AC15)) | |
| Output fuse | 6 A gL/gG |
| 4 A gL/gG (for low-demand applications) |
| Output description | PNP |
|---|---|
| Number of outputs | 1 (non-safety-related) |
| Voltage | approx. 22 V DC (Us- 2 V) |
| Current | max. 100 mA |
| Maximum inrush current | 500 mA (Δt = 1 ms at Us) |
| Short-circuit protection | no |
| Output fuse | 150 mA fast blow |
| Typical pickup time at US | < 200 ms (when controlled via A1, automatic start) |
|---|---|
| Typical release time at US | < 35 ms (when controlled via A1) |
| Recovery time | 500 ms |
| Relay type | Electromechanical relay with forcibly guided contacts in accordance with IEC/EN 61810-3 (EN 50205) |
|---|---|
| Nominal operating mode | 100% operating factor |
| Net weight | 196 g |
| Mounting position | vertical, horizontal, with front of module upward |
| Mounting type | DIN rail mounting |
| Assembly instructions | See derating curve |
| Degree of protection | IP20 |
| Min. degree of protection of inst. location | IP54 |
| Housing material | PBT |
| Housing color | yellow |
| Operating voltage display | 1 x yellow LED |
| Status display | 2 x green LEDs |
| Indication | 1 x red LED |
| Connection method | Spring-cage connection |
|---|---|
| pluggable | Yes |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
| Stop category | 0 |
|---|---|
| Designation | IEC 61508 - High demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | 3 |
| Designation | EN 50156 |
| Safety Integrity Level (SIL) | 3 |
| Designation | Air clearances and creepage distances between the power circuits |
|---|---|
| Standards/regulations | DIN EN 50178, EN 60079-15 |
| Rated insulation voltage | 250 V AC |
| Rated surge voltage/insulation | Safe isolation, 6 kV reinforced insulation from control circuit, start circuit, signal output to the enabling current paths, 4 kV/basic insulation between the enabling current paths and between all current paths and housing |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Shock | 15g |
| Vibration (operation) | 2g |
| Conformance | CE-compliant |
| UL, USA/Canada | cULus |
| Class I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X | |
| Class I, Div. 2, Groups A, B, C, D, T4 | |
| GL | C, EMC2 |
| Environmental simulation test | ISA-S71.04 (G3) |
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |
| Feature Name | Feature Value |
|---|---|
| Model (EF000010) | Basic device |
| Suitable for rail mounting (EF003972) | Yes |
| With detachable clamps (EF003340) | Yes |
| Type of electric connection (EF003961) | Spring clamp connection |
| Suitable for monitoring of emergency-stop circuits (EF007268) | No |
| Suitable for monitoring of valves (EF007272) | No |
| Suitable for monitoring of optoelectronic protection equipment (EF007269) | No |
| Suitable for monitoring of tactile sensors (EF007271) | No |
| Suitable for monitoring of magnetic switches (EF007266) | No |
| Suitable for monitoring of proximity switches (EF007267) | No |
| Evaluation inputs (EF008245) | Other |
| With start input (EF003342) | No |
| With muting function (EF004057) | No |
| With feedback circuit (EF003343) | No |
| Release-delay (EF001129) | 0.2 s |
| Number of outputs, safety related, undelayed, with contact (EF003344) | 0 |
| Number of outputs, safety related, delayed, with contact (EF003345) | 0 |
| Number of outputs, safety related, undelayed, semiconductors (EF003346) | 0 |
| Number of outputs, safety related, delayed, semiconductors (EF003347) | 0 |
| Number of outputs, signalling function, undelayed, with contact (EF003348) | 0 |
| Number of outputs, signalling function, delayed, with contact (EF003349) | 0 |
| Number of outputs, signalling function, undelayed, semiconductors (EF003350) | 0 |
| Number of outputs, signalling function, delayed, semiconductors (EF003351) | 0 |
| Stop category according to IEC 60204 (EF007498) | Other |
| With approval for BG BIA (EF004145) | No |
| With approval according to UL (EF001783) | No |
| Width (EF000008) | 12.5 mm |
| Height (EF000040) | 116.6 mm |
| Depth (EF000049) | 114.5 mm |