PHOENIX CONTACT PSR-PC40-2NO-1DO-24DC-SC PSR-PC40-2NO-1DO-24DC-SC 2700588 PHOENIX CONTACT Coupling relay View larger
Images are for illustrative purposes only. Please refer to data sheet for details

PSR-PC40-2NO-1DO-24DC-SC 2700588 PHOENIX CONTACT Coupling relay

PSR-PC40-2NO-1DO-24DC-SC

2700588

PHOENIX CONTACT

1 Pcs.

Coupling relay Coupling relay for high and low demand applications SIL 3, couples digital output signals to the periphery, 2 trip circuits, 1 digital warning output, Safe-State-Off applications, test pulse filter, plug-in screw terminal block Coupling relay for SIL 3 high- and low-demand applications, couples digital output signals to the I/O, 2 enabling current paths, 1 digital signal output, safe state off applications, test pulse filter, plug-in screw terminal block

Automation > Device for monitoring of safety-related circuits
Safety

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Notes
Note on application
Note on applicationOnly for industrial use
Utilization restriction
CCCex noteUse in potentially explosive areas is not permitted in China.

Product properties
Product typeCoupling relay
Product familyPSRmini
ApplicationSafe switch off
High demand
Low demand
Ex
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Data management status
Article revision07
Times
Typ. starting time with Us< 200 ms (when controlled via A1, automatic start)
Typical release time< 35 ms (when controlled via A1)
Recovery time500 ms

Electrical properties
Maximum power dissipation for nominal condition5.5 W (IL² = 60 A²)
Nominal operating mode100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage250 V AC
Rated surge voltage/insulationSafe isolation, 6 kV reinforced insulation from control circuit, start circuit, signal output to the enabling current paths, 4 kV/basic insulation between the enabling current paths and between all current paths and housing
Supply
DesignationA1/A2
Rated control circuit supply voltage US20.4 V DC ... 26.4 V DC
Rated control circuit supply voltage US24 V DC -15 % / +10 % (A1/A2)
Rated control supply current IStyp. 75 mA (depending on load M1 +100 mA)
Power consumption at UStyp. 1.8 W
Inrush currenttyp. 400 mA (Δt s)
Filter timemax. 2 ms (at A1-A2; test pulse width)
≥ 100 ms (at A1-A2; test pulse rate)
Protective circuitSerial protection against polarity reversal; 33 V suppressor diode

Input data
Digital: Start circuit (Y1, Y2)
Number of inputs2 (Non-safety-related start inputs: Y1/Y2)
Inrush current< 10 mA
Max. permissible overall conductor resistance150 Ω
Voltage at input/start and feedback circuit24 V DC -15 %; +10 %
Current consumption< 5 mA

Output data
Relay: Enabling current paths (13/14, 23/24)
Output description2 NO contacts each in series, without delay, floating
Number of outputs2 (safety-related N/O contacts: 13/14, 23/24)
Contact switching type2 enabling current paths
Contact materialAgSnO2
Switching voltagemin. 12 V AC/DC
max. 250 V AC/DC (Observe the load curve)
Switching capacitymin. 60 mW
Inrush currentmin. 3 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-14 A (24 V (DC13))
5 A (250 V (AC15))
Limiting continuous current6 A (High demand)
4 A (Low demand)
Sq. Total current60 A2(observe derating)
Switching frequencymax. 0.5 Hz
Mechanical service life10x 106cycles
Output fuse6 A gL/gG
4 A gL/gG (for low-demand applications)
Signal: M1
Output descriptionPNP
Number of outputs1 (non-safety-related)
Voltageapprox. 22 V DC (Us- 2 V)
Currentmax. 100 mA
Maximum inrush current500 mA (Δt = 1 ms at Us)
Short-circuit protectionno
Output fuse150 mA fast blow

Connection data
Connection technology
pluggableyes
Conductor connection
Connection methodScrew connection
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross-section AWG24 ... 12
Stripping length7 mm
Screw threadM3
Tightening torque0.5 Nm ... 0.6 Nm

Signaling
Status display2 x LED (green)
Operating voltage display1 x yellow LED
Error indication1 x LED (red)

Dimensions
Width12.5 mm
Height112.2 mm
Depth114.5 mm

Material specifications
Color (Housing)yellow (RAL 1018)
Housing materialPolyamide

Characteristics
Safety data
Stop category0
Safety data: EN 50156
Safety Integrity Level (SIL)3
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL)3
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL)3

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Ambient temperature (operation)-40 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (operation)10 Hz ... 150 Hz, 2g

Approvals
ATEX
Identification II 3G  Ex ec nC IIC T4 Gc
CertificateUL 22 ATEX 2912X
IECEx
IdentificationEx ec nC IIC T4 Gc
CertificateIECEx UL 22.0037X
UL, USA/Canada
IdentificationcULus
CertificateE140324
UL Ex, USA / Canada
IdentificationClass I, Zone 2, AEx nA nC IIC T4 / Ex nA nC IIC Gc T4 X
Class I, Div. 2, Groups A, B, C, D, T4
CertificateE360692
CE
IdentificationCE-compliant
Environmental simulation test
IdentificationG3
CertificateISA-S71.04
CCC / China-Ex
IdentificationEx ec nC IIC T4 Gc
Certificate2022122304115695
DNV
IdentificationC, EMC2
Certificate11253-14 HH

Standards and regulations
Air clearances and creepage distances between the power circuits
Standards/regulationsEN 60664-1, EN 60079-7, EN 60079-15

Mounting
Mounting typeDIN rail mounting
Assembly noteSee derating curve
Mounting positionvertical, horizontal, with front of module upward

ETIM for 2700588 Relays (EC001449)
Feature Name Feature Value
Model (EF000010) Basic device
Suitable for rail mounting (EF003972) Yes
With detachable clamps (EF003340) Yes
Type of electric connection (EF003961) Screw connection
Suitable for monitoring of emergency-stop circuits (EF007268) No
Suitable for monitoring of valves (EF007272) No
Suitable for monitoring of optoelectronic protection equipment (EF007269) No
Suitable for monitoring of tactile sensors (EF007271) No
Suitable for monitoring of magnetic switches (EF007266) No
Suitable for monitoring of proximity switches (EF007267) No
Evaluation inputs (EF008245) Other
With start input (EF003342) No
With muting function (EF004057) No
With feedback circuit (EF003343) No
Release-delay (EF001129) 0.2 s
Number of outputs, safety related, undelayed, with contact (EF003344) 0
Number of outputs, safety related, delayed, with contact (EF003345) 0
Number of outputs, safety related, undelayed, semiconductors (EF003346) 0
Number of outputs, safety related, delayed, semiconductors (EF003347) 0
Number of outputs, signalling function, undelayed, with contact (EF003348) 0
Number of outputs, signalling function, delayed, with contact (EF003349) 0
Number of outputs, signalling function, undelayed, semiconductors (EF003350) 0
Number of outputs, signalling function, delayed, semiconductors (EF003351) 0
Stop category according to IEC 60204 (EF007498) Other
With approval for BG BIA (EF004145) No
With approval according to UL (EF001783) No
Width (EF000008) 12.5 mm
Height (EF000040) 112.2 mm
Depth (EF000049) 114.5 mm

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.