PHOENIX CONTACT UKK 5-2 BE UKK 5-2 BE 3048030 PHOENIX CONTACT Component terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details

UKK 5-2 BE 3048030 PHOENIX CONTACT Component terminal block

UKK 5-2 BE

3048030

PHOENIX CONTACT

50 Pcs.

Component terminal block Terminal block for components, Maximum width of the components to be soldered: 5 mm, nominal voltage: 500 V, nominal current: 32 A, 1st and 2nd floor, connection type: Screw connection, Dimensioning section: 4 mm², cross-section: 0.2 mm² - 4 mm², mounting: NS 35/7.5, NS 35/15, NS 32, color: gray

Automation > Component terminal block
Modular TBs

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Key Commercial Data

Orderkey3048030
Packing unit50 pc
Minimum order quantity50 pc
Catalog pagePage 492 (C-1-2017)
GTIN4017918864033
Weight per Piece (excluding packing)15.100 g
Custom tariff number85369010
Country of originPL (Poland)

General

NoteMaximum width of components to be soldered in: 5 mm
Number of levels2
Number of connections4
Nominal cross section4 mm²
Colorgray
Insulating materialPA
Flammability rating according to UL 94V0
Rated surge voltage6 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Connection in acc. with standardIEC 60947-7-1
Nominal current IN32 A
Maximum load current32 A (with 4 mm² conductor cross section)
Nominal voltage UN500 V (Data is based on the dielectric strength of adjacent terminal blocks or of the DINg rail.)
Open side panelYes
Number of positions2
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width6.2 mm
Length56 mm
Height NS 35/7,562 mm
Height NS 35/1569.5 mm
Height NS 3267 mm

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Conductor cross section flexible, with ferrule without plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.4 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.2.5 mm²
2 conductors with same cross section, solid min.0.2 mm²
2 conductors with same cross section, solid max.1.5 mm²
2 conductors with same cross section, stranded min.0.2 mm²
2 conductors with same cross section, stranded max.1.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.0.25 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.1.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.0.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.1.5 mm²
Connection methodScrew connection
Stripping length8 mm
Internal cylindrical gageA4
Screw threadM3
Tightening torque, min0.6 Nm
Tightening torque max0.8 Nm

Standards and Regulations

Connection in acc. with standardIEC 60947-7-1
Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


ETIM for 3048030 Terminal blocks (EC000903)
Feature Name Feature Value
Connectable conductor cross section fine-strand without cable end sleeve (EF007341) 0.2 mm²
Connectable conductor cross section fine-strand with cable end sleeve (EF007339) 0.25 mm²
Connectable conductor cross section solid-core (EF007337) 0.2 mm²
Connectable conductor cross section multi-wired (EF007343) 0.2 mm²
Rated current In (EF008250) 32 A
Rated voltage (EF000228) 500 V
Type of electrical connection 1 (EF002526) Screw connection
Type of electrical connection 2 (EF002527) Screw connection
Number of levels (EF002659) 2
Number of clamp positions per level (EF002660) 2
Internally connected stages (EF002661) No
Mounting method (EF000003) DIN rail (top hat rail) 35 mm
Material insulation body (EF007543) Other
Inflammability class of insulation material according to UL94 (EF002521) V0
Width (EF000008) 6.2 mm
Height (EF000040) 56 mm
Depth (EF000049) 62 mm
Closing plate required (EF002525) Yes
Colour (EF000007) Grey

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.