PHOENIX CONTACT CHARX PS-M2/825DC/1000DC/30KW CHARX PS-M2/825DC/1000DC/30KW 1296467 PHOENIX CONTACT CHARX power basic, Fast charging module for mounting D.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

CHARX PS-M2/825DC/1000DC/30KW 1296467 PHOENIX CONTACT CHARX power basic, Fast charging module for mounting D..

CHARX PS-M2/825DC/1000DC/30KW

1296467

PHOENIX CONTACT

1 Pcs.

CHARX power basic, Fast charging module for mounting DC charging posts, 19" rack mounting, output: 30 V DC... 1000 V DC / 0 A... 100 A CHARX power basic, Fast charging module for setting up DC charging stations, 19" rack mounting, CAN bus, output: 30 V DC...1000 V DC / 0 A...100 A

Automation > DC-power supply

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Technical data

Input data
DC operation
Input voltage range300 V DC ... 825 V DC
Derating< 650 V DC ... 300 V DC (46 W/V)
Nominal input voltage range650 V DC ... 825 V DC
Input current48 A (650 V DC)
38 A (825 V DC)
Inrush current limitation< 60 A
Insulation resistance> 10 MΩ
Supply system configurationDC grid (DC±, PE)

Output data
Efficiency> 95 % (POut>50%)
Output voltage range30 V DC ... 1000 V DC
Output current range0 A ... 100 A
Nominal power30 kW
Power dissipation standby< 14 W
Protection against overvoltage at the output (OVP)> 1040 V DC
Derating> 55 °C (3.2 A/K)
> 55 °C (1 kW/K)
Control deviation< 0.5 % (Voltage deviation static load change 20% ... 100%)
< 1 % (Current deviation Static load change 20 % ... 100 %)
± 0.2 % (Input voltage change ±20 %)
Switch-on delay< 8 s
Overshoot behavior± 3 % (Switch-on procedure)

Energy storage
Battery technologyLi-Ion

Connection data
Input
DesignationInput
IdentificationDC IN: + / - / PE
Conductor connection
Connection methodPush-in connection
rigid1.5 mm² ... 16 mm²
10 mm² (recommended)
flexible1.5 mm² ... 16 mm²
10 mm² (recommended)
rigid (AWG)15 ... 5 (Cu)
7 (recommended)
Stripping length18 mm (rigid/flexible)
Output
DesignationOutput
IdentificationDC OUT: + / -
Conductor connection
Connection methodT-LOX knee lever connection
rigid10 mm² ... 50 mm²
25 mm² (recommended)
flexible16 mm² ... 50 mm²
25 mm² (recommended)
rigid (AWG)8 ... 0 (Cu)
16 (recommended)
Stripping length20 mm (10 mm² ... 25 mm² = 18 mm, 35 mm² ... 50 mm² = 20 mm)

Interfaces
InterfaceCAN bus
Number of interfaces1
Connection method2x RJ45 (pin assignment, CANopen standard)
LockingLocking clip
Transmission physicsTwisted-Pair
TopologyLine (daisy-chain connection)
Transmission speed125 kbps
Transmission lengthmax. 20 m
Supported protocolsCAN 2.0B
Electrical isolationyes (primary/secondary)
no (PE)
Number of power modules as CAN bus devicesmax. 48 (within one CHARX control controller)
Termination resistor120 Ω (Terminating the end device)

Electrical properties
Electrical isolation between input and outputyes
Insulation voltage input/output2121 V DC
Insulation voltage input, output / housing2121 V DC
Insulation voltage input, output/signal, communication4242 V DC
Insulation voltage signal, communication/housing707 V DC

Product properties
Product typeDC power module
Product familyCHARX power basic
MTBF (IEC 61709, SN 29500)> 300000 h
Service life40000 h (40 °C)
70000 h (40 °C, fan)
Internal fanyes
Flow directionfrom front to back
Insulation characteristics
Protection classI
Pollution degree2

Dimensions
Item dimensions
Width483 mm
Height134 mm
Depth550 mm
Dimensional drawingjpvxjdojik.jpg
Rack unit3 U

Mounting
Mounting type19" rack mounting

Material specifications
Housing materialZn-Al alloy

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Overtemperature protection (OTP)> 75 °C
Maximum altitude≤ 4000 m (Derating >2000 m: 10% / 1000 m)
Permissible humidity (operation)≤ 95 % (non-condensing)
Noise level< 60 dB (1 m)

Standards and regulations
Overvoltage category
IEC 60664-1II
Electric vehicle conductive charging system - Part 1: General requirements
Standard designationElectric vehicle conductive charging system - Part 1: General requirements
Standards/specificationsIEC 61851-1
Electric vehicle conductive charging system – Part 23: DC electric vehicle charging station
Standard designationConductive charging systems for electric vehicles – Part 23: DC supply equipment for electric vehicles
Standards/specificationsIEC 61851-23

EMC data
EMC requirements for noise emissionEN 61000-6-3
EMC requirements for noise immunityEN 61000-6-1

ETIM for 1296467 Low-voltage industrial controls and switchgear (EC002540)
Feature Name Feature Value
Voltage type (supply voltage) (EF002991) DC
1st secondary output voltage (EF006792) 30 V
Max. output current 1 (EF008284) 100 A
Secondary voltage adjustable (EF007002) Yes
Nominal value output current 1 (EF009396) 100 A
Short-circuit-proof (EF007332) Yes
Output voltage stabilized (EF003092) Yes
Power consumption (EF000346) 31577 VA
Power output (EF003034) 30000 W
Stabilized (EF005302) Yes
Type of electric connection (EF003961) Other
Suitable for rail mounting (EF003972) No
Wall mounting possible (EF003973) No
Modular version (EF001126) No
Built-in height (EF000332) 134 mm
Direct mounting possible (EF005689) No
Width (EF000008) 483 mm
Height (EF000040) 134 mm
Depth (EF000049) 550 mm
Suitable for safety functions (EF001597) No
Performance level according to EN ISO 13849-1 (EF007399) None
Degree of protection (IP) (EF005474) IP20
Degree of protection (NEMA) (EF011959) Other

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.